journal article·2022-12Open access

Flame heights and charring on a particle board – An experimental study

Dheeraj Dilip Karyaparambil, Sveinung Erland, Patrick van Hees, Vidar Frette, Bjarne Christian Hagen

Fire Safety Journal· Volume 134

Abstract

Vertically oriented particle-board samples were exposed to external venting flames to study the fire spread and charring behaviour along a timber façade. Variation in flame height and the height, volume, area, density, and depth of the char layer were studied to determine the impact of heat-release rate and experiment duration. There was a peak flame height after which the flame returned to steady height approximately equal to the value before the ignition of the particle board and flame heights with inert panels. Flames did not spread to the top of the panel with increased experiment duration. Char height and area were found to increase with heat-release rate but were not affected significantly by experiment duration. Char depth and volume increased with both experiment duration and heat-release rates. Char density decreased with increased experiment duration and heat-release rate.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Introduction
2. 2021
3. Top 5 tallest timber buildings in the world
4. Abrahamsen · 2017 · 13
5. List of facade fires 1990 - 2020, build
6. 2019
7. Carlson · 2021
8. A review of factors affecting the burning behaviour of wood for application to tall timber construction10.1007/s10694-018-0787-y ↗
9. Characteristics of externally venting flames and their effect on the façade: a detailed experimental study10.1007/s10694-016-0575-5 ↗
10. Temperature evolution and external flame height through the opening of fire compartment: scale effect on heat/mass transfer and revisited models10.1016/j.ijthermalsci.2021.106849 ↗
11. Saito
12. Experimental measurements of upward flame spread on a vertical wall with external radiation10.1016/S0379-7112(98)00012-5 ↗
13. Thermography of wood-base panels during fire tests in laboratory and field conditions
14. Experimental study on vertical wooden façade combustion10.1016/j.proeng.2017.11.109 ↗
15. Visible structure of buoyant diffusion flames10.1016/S0082-0784(85)80522-1 ↗
16. Heat fluxes and flame heights in façades from fires in enclosures of varying geometry10.1016/j.proci.2006.08.033 ↗
17. Sjöström · 2021
18. On the flame height definition for upward flame spread10.1016/j.firesaf.2006.12.008 ↗
19. Window ejected flame width and depth evolution along facade from under-ventilated enclosure fires10.1016/j.firesaf.2015.05.001 ↗
20. Geometrical characteristics of externally venting flames: assessment of fire engineering design correlations using medium-scale compartment-façade fire tests10.1016/j.jlp.2016.09.006 ↗
21. Timber structures
22. Material properties and external factors influencing the charring rate of solid wood and glue-laminated timber10.1002/fam.1055 ↗
23. Self-extinction of timber10.1016/j.proci.2016.07.077 ↗
24. Combustion and charring properties of five common constructional wood species from cone calorimeter tests10.1016/j.conbuildmat.2015.08.062 ↗
25. Experimental and numerical investigation of externally venting flame developing in a corridor-façade configuration
26. Fire scenarios for multi-storey façades with emphasis on full-scale testing of wooden façades10.1007/s10694-015-0508-8 ↗
27. Fire safety assessment of wooden facades10.1002/fam.780 ↗
28. Brandon · 2020
29. Thomas · 1972
30. Würth Norge
31. Ignitability measurements with the cone calorimeter10.1002/fam.810110103 ↗
32. Ignition of New Zealand wood products in the LIFT, RIFT and ISO 5657 apparatus using the ASTM e 1321-97 protocol10.1177/0734904107085381 ↗
33. Flame spread measurements on wood products using the ASTM E 1321 LIFT apparatus and a reduced scale adaptation of the cone calorimeter10.1002/fam.1001 ↗
34. Forestia
35. Thermal properties of wood-based panels: specific heat determination10.1007/s00226-016-0803-7 ↗
36. Ytong · Tech. Data · 2020
37. Analysis of thermal insulation performance of aerated concrete block wall in solar greenhouse
38. Drysdale
39. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
40. Effect of sidewall on the flame extension characteristics beneath a ceiling induced by carriage fire in a channel10.1016/j.combustflame.2020.09.020 ↗
41. A physical model for flame height intermittency10.1007/s10694-017-0678-7 ↗
42. Upward flame spread on wooden surface products: experiments and numerical modelling10.3801/IAFSS.FSS.5-309 ↗
43. Heat of combustion of various southern pine materials
44. Structural timber in compartment fires – the timber charring and heat storage model10.1515/eng-2021-0043 ↗
45. Abbrandgeschwindigkeit von Holz und Holzwerkstoffen in Abhängigkeit von der Rohdichte, der Spangröße und der Ausrichtung der Späne10.1007/s00107-011-0565-8 ↗
46. Critical mass flux for flaming ignition of wood as a function of external radiant heat flux and moisture content
47. Vertical temperature profile of fire-induced facade thermal plume ejected from a fire compartment window with two adjacent side walls10.1016/j.applthermaleng.2016.11.018 ↗
48. Experimental study on flame height and temperature profile of buoyant window spill plume from an under-ventilated compartment fire10.1016/j.ijheatmasstransfer.2011.08.045 ↗
49. Time dependent contribution of char oxidation and flame heat feedback on the mass loss rate of timber
50. Analysis of wood structural changes under thermal radiation10.1021/ef800873k ↗
51. The post-flashover compartment fire
52. Oleszkiewicz
53. Thomas · 1972