journal article·2020-08Open access

Fire hazard of compressed straw as an insulation material for wooden structures

Frederic Blondin, Pierre Blanchet, Christian Dagenais, Zafiris Triantafyllidis, Luke Bisby

Fire and Materials· Volume 44· Issue 5

Abstract

SUMMARY The construction sector continues to adapt to the challenges posed by climate change. Architects and engineers aim to build sustainable, energy, resource, and cost‐efficient structures by increasingly using bio‐based building materials. However, fire safety has always been a significant concern for timber building construction internationally. The objective of the study presented in this article is to document fire hazards of compressed straw when used as thermal and acoustic insulation within wood‐framed building assemblies. Three densities of compressed straw (75, 125, and 175 kg/m3) were selected and their combustion and thermal responses were evaluated at various scales, in attempt to define the optimal density considering various factors. The performance of the straw was also compared with commercially available insulation materials and then tested under exposure to severe heating in medium‐scale wood‐framed assemblies to evaluate the impacts of the straw as compared with a noncombustible insulation. The compressed straw with a density of 75 kg/m3 was found to have the best behavior with respect to both reactions to fire and insulation properties. The results suggest that compressed may have similar or better behavior under the heating conditions investigated when compared to a commercially available combustible insulation material. The use of this material as a primary insulation in a buildings is considered manageable by thoughtful design, construction, and building use without unduly increasing risks associated with fire.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hygrothermal properties of building materials · Wood Treatment and Properties · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Sciences du bois, Faculte de foresterie, de geographie et de geomatique Université Laval Quebec City Quebec Canada

Advanced Building Systems FPInnovations Pointe‐Claire Quebec Canada

Fire Safety Engineering, School of Engineering The University of Edinburgh Edinburgh UK

Funding

FPInnovations · Natural Sciences and Engineering Research Council of Canada

References (46)

Show source-provided references
1. Baharetha SM · 2013 · 732
2. UNEP. Buildings and climate change: summary for decision‐makers; 2009.
3. 10.1016/j.proeng.2011.11.209010.1016/j.proeng.2011.11.2090 ↗
4. 10.1016/j.egypro.2015.11.21910.1016/j.egypro.2015.11.219 ↗
5. 10.1016/j.enbuild.2004.05.00610.1016/j.enbuild.2004.05.006 ↗
6. 10.1080/10789669.1999.1039123610.1080/10789669.1999.10391236 ↗
7. 10.1016/j.conbuildmat.2016.11.02010.1016/j.conbuildmat.2016.11.020 ↗
8. 10.1016/j.conbuildmat.2012.09.01110.1016/j.conbuildmat.2012.09.011 ↗
9. NBCC · 2010
10. EN 1995‐1‐2. Eurocode 5—Design of timber structures Part 1‐2: General—Structural fire design.Eurocode 5 – Design of Timber Structures; 2004. doi:https://doi.org/10.1680/cien.2001.144.6.3910.1680/cien.2001.144.6.39 ↗
11. Canadian Wood Council.Fire Safety Design in Buildings. Ottawa; 1996.
12. NA ITS.ASTM E 119‐05a:2‐Hr Fire Resistance Test of A Non‐Loadbearing Wheat Straw Bale Wall;2007.
13. DzidicS.Fire Resistance of the Straw Bale Walls; 2017. doi:https://doi.org/10.14415/konferencijaGFS2017.04410.14415/konferencijaGFS2017.044 ↗
14. 10.2495/SAFE09006110.2495/SAFE090061 ↗
15. NFPA. Report of committee on fire‐resistive construction. Proceedings of the 21st National Fire Protection Association Annual Meeting; 1917:391‐413.
16. Freitag JK · 1912
17. WoolsonIH. For fire prevention.New York Tribune; 1904:8.
18. ISO.Reaction‐to‐Fire Tests—Heat Release Smoke Production and Mass Loss Rate—Part 1:Heat Release Rate (Cone Calorimeter Method) and Smoke Production Rate (Dynamic Measurement) (ISO 5660‐1). Geneva Switzerland; 2015.
19. Spearpoint M · 2008
20. CEN.Eurocode: Fire Resistance Tests—Part 1: General Requirements (EN 1363–1:2012); 2012:56.
21. ASTM.Standard Test Methods for Fire Tests of Building Construction and Materials (ASTM E119). Conshohocken PA;2000.
22. ULC.Standard Methods of Fire Endurance Tests of Building Construction and Materials (CAN/ULC‐S101). Ottawa ON: Underwriters Laboratories of Canada; 2007.https://www.scc.ca/fr/standardsdb/standards/23507. Accessed March 22 2018.
23. 10.1016/j.firesaf.2017.05.00910.1016/j.firesaf.2017.05.009 ↗
24. Surface flame propagation on cellulosic materials exposed to thermal radiation
25. 10.1002/fam.81006020610.1002/fam.810060206 ↗
26. 10.2172/103250310.2172/1032503 ↗
27. ASTM.Standard Test Methods for Measurement of Material Flammability Using a Fire Propagation Apparatus (FPA) (ASTM E2058). Conshohocken PA;2002.
28. ISO.Reaction to Fire Tests—Measurement of Material Properties Using a Fire Propagation Apparatus (ISO 12136:2011). Geneva Switzerland; 2011.
29. ULC. Standard test method for the determination of combustibility parameters of building materials using an oxygen consumption calorimeter (cone calorimeter) (ULC‐S135); 2016.https://www.scc.ca/fr/standardsdb/standards/20035. Accessed March 27 2018.
30. ASTM.Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter (ASTM E1354). Conshohocken PA;2013.
31. Need for and some remarks on internationally standardized fire test procedures
32. 10.1007/BF0198305810.1007/BF01983058 ↗
33. SultanMA. Comparison of furnace temperature and incident heat flux in wall and floor furnaces controlled by six different temperature sensors.Proceedings of the 12th International Conference Fire Science & Engineering (Interflam) London UK; 2010:341‐352.
34. LawM BeeverP. Magic numbers and golden rules; 1995.10.1007/BF01305269 ↗
35. Dagenais C · 2016
36. 10.1016/j.firesaf.2016.05.00110.1016/j.firesaf.2016.05.001 ↗
37. Grenier AT · 1997 · 253
38. ISO.Thermal Insulation—Determination of Steady‐State Thermal Resistance and Related Properties—Heat Flow Meter Apparatus (ISO 8301). Geneva Switzerland; 1991.
39. 10.1002/978111997546510.1002/9781119975465 ↗
40. GUTEX. GUTEX Multitherm®. Datasheet; 2018.http://gutex.ch/fr/sortiment/produits/produit/prod/gutex-multitherm/
41. GUTEX. GUTEX Thermowall®‐gf. Datasheet; 2018.http://gutex.fr/notre-gamme/produits/produit/prod/gutex-thermowall-gf/
42. Owens Corning. FOAMULAR® 250 Extruded Polystyrene (XPS) Rigid Foam Insulation. Datasheet; 2016.https://dcpd6wotaa0mb.cloudfront.net/mdms/dms/EIS/43522/43522-FOAMULAR-250-XPS-Insulation-Product-Data-Sheet.pdf?v=1474969868000
43. ISO.Fire Resistance Tests—Elements of Building Construction (ISO 834). Geneva Switzerland; 2014.
44. 10.1016/S0379-7112(02)00090-510.1016/S0379-7112(02)00090-5 ↗
45. 10.1007/s10694-005-3730-y10.1007/s10694-005-3730-y ↗
46. 10.1016/j.tws.2013.01.00510.1016/j.tws.2013.01.005 ↗