journal article·1995-01

Fire‐endurance testing of building constructions containing wood members

L. R. Richardson, D. M. Onysko

Fire and Materials· Volume 19· Issue 1
Publisher page

Abstract

Abstract In the later part of 1992 the National Research Council of Canada (NRC), in collaboration with a number of industry and governmental partners, commenced a research program to quantify sound‐transmission‐class and fire‐resistance ratings for gypsum‐board protected wood‐frame and steel‐frame building assemblies. The ‘partners’ include Forintek Canada Corp. acting on behalf of Canada's wood products industry. Although thousands of fire‐resistance tests have been carried out over the past century, many of which were on wood‐frame constructions, three interrelated issues arose in regard to the wood studs used in these tests: moisture content, strength, and magnitude of the load superimposed on the walls that the studs would be required to withstand during the fire tests. This paper discusses those issues.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Wood Treatment and Properties · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Associate Committee of the National Building Code of Canada 1990 National Building Code of Canada 1990 National Research Council of Canada Ottawa.
2. Associate Committee of the National Building Code of Canada 1990 Supplement to the National Building Code of Canada 1990 National Research Council of Canada Ottawa.
3. M.Galbreath G.GosselinandR.Chauhan Historical Guide to Chapter 2 of the Supplement to the National Building code of Canada Committee Paper prepared for the Standing Committee on Fire Performance Ratings Ottawa (1987).
4. C. R.Thomson Component additive method for estimating fire resistance. National Conference Publication No. 89/16 The Institution of Engineers Australia Melbourne (1989).
5. Canadian Standards Association Gypsum Board National Standard of CanadaCAN/CSA‐A82.27‐M91 Rexdale (1991).
6. S.Grayson(ed.) Fire performance of gypsum wallboard assemblies.Fire and Flammability BulletinSeptember (1993).
7. Underwriters' Laboratories of Canada Standard methods of fire endurance tests of building construction and materials. National Standard of Canada CAN/ULC‐S101‐M89. Scarborough (1989).
8. ASTMDesignation E 119‐88 Standard Test Method for Fire Tests of Building Construction and Materials ASTM Philadelphia.
9. National Lumber Grades Authority Standard Grading Rules for Canadian Lumber(1987).
10. Canadian Standards Association Softwood Lumber National Standard of CanadaCAN/CSA‐O141‐91 Rexdale (1991).
11. Canadian Standard Association Engineering Design in Wood (Limit States Design) National Standard of CanadaCAN/CSA‐O86.1‐M89 Rexdale (1989).
12. P.Garahan J.MeilandD. M.Onysko Moisture in Framing Lumber‐Field Measurement Acceptability and Use Surveys Forintek Canada Corp. Report to Canada Mortgage and Housing Corporation Ottawa (1991).
13. United States Department of Agriculture Wood Handbood: Wood as an engineering material Agriculture Handbook 72 Madison (1987).
14. R. A.McPheeandC.Lalonde Personal communication Canadian Wood Council Ottawa (1993).
15. National Forest Products Association National Design Specification for Wood Construction Washington DC (1991).