journal article·2013-01

Cone calorimeter evaluation of two flame retardant cotton fabrics

Robert H. White, Sunghyun Nam, Dharnidhar V. Parikh

Fire and Materials· Volume 37· Issue 1
Publisher page

Abstract

SUMMARY Unbleached (gray) cotton needle‐punched nonwoven (NW) fabrics with 12.5% polypropylene scrim were treated with two phosphate–nitrogen‐based flame retardant (FR) formulations, Southern Regional Research Center (SRRC)‐1 and SRRC‐2. The SRRC‐1 formulation contains diammonium phosphate as the FR chemical along with urea and dimethyloldihydroxyethyleneurea. Because a trace amount of formaldehyde was still expected to be released from SRRC‐1‐treated FR cotton under high heat, it was preferable to eliminate the dimethyloldihydroxyethyleneurea, leading to the revised formulation SRRC‐2. It has a higher content of diammonium phosphate and did not use the polyethylene emulsion that was in SRRC‐1. Both formulations were of low cost as they were developed at SRRC using industrial grade chemicals. The fabrics were evaluated with a cone calorimeter using three heat flux levels, 20, 30, and 50 kW/m2. On the basis of the overall cone calorimeter results for heat released and ignition times, FR NW fabrics that were treated with SRRC‐2 were found to be slightly superior in flammability properties to those treated with the earlier SRRC‐1 formulation, but the differences were statistically insignificant. Both preparations were much less flammable than the untreated control cotton NW fabrics. Compared with the untreated NW fabrics, the FR fabrics had higher visible smoke production. Copyright © 2012 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Flame retardant materials and properties · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Forest Product Laboratory Forest Service, USDA One Gifford Pinchot Drive Madison WI 53726‐2398 USA

Southern Regional Research Center Agricultural Research Service, USDA 1100 Robert E. Lee Blvd. New Orleans LA 70124 USA

References (30)

Show source-provided references
1. International Sleep Products Association · 2010
2. 10.1002/pat.109210.1002/pat.1092 ↗
3. National Cotton Batting Institute
4. OliverK.Cotton: the natural choice for fire safety in mattresses. In CD ofProceedings of the Beltwide Cotton Conferences 2005–2009 2009;1416.
5. Haneke K · 2002 · 25
6. 10.1016/j.polymdegradstab.2010.03.03610.1016/j.polymdegradstab.2010.03.036 ↗
7. 10.1177/00405175740440091010.1177/004051757404400910 ↗
8. 16 CFR part 1633, final rule: standard for the flammability (open flame) of mattress sets
9. GeorgeCW SusottRA.Effects of ammonium phosphate and sulfate on the pyrolysis and combustion of cellulose. Research Paper INT‐90.USDA Forest Service Intermountain Forest and Range Experiment Station:Ogden UT 1971;27.10.5962/bhl.title.68725 ↗
10. FR/resilient perpendicular‐laid nonwovens containing cotton
11. 10.1177/073490410303611410.1177/0734904103036114 ↗
12. 10.1177/152808370809891210.1177/1528083708098912 ↗
13. ParikhDV PrevostN SmithJ SolhjooH ChangS CondonB.FR greige cotton barrier technologies: fire barrier for mattresses to comply with 16 CFR 1633. Presentation at Barrier Fabrics Workshop at National Institute of Standards and Technology March2009.http://www.bfrl.nist.gov/866/barrierfabric/presentations/12%20Parikh_NIST%20workshop%20March09%20FINAL.pdf[accessed 04/25/2011].
14. 10.1177/00405175700400030410.1177/004051757004000304 ↗
15. NamS ParikhDV CondonB.Phosphorus–nitrogen synergism in the fire barrier of greige cotton nonwoven fabrics. InProceedings of the Beltwide Cotton Conference 2000;1591–1596.
16. Consumer Products Safety Commission.Laboratory test manual for 16 CFR part 1633: standard for the flammability (open‐flame) of mattress sets2011 50.https://www.cpsc.gov/businfo/labmanual.pdf[accessed 04/25/2011].
17. TenneyA.16 CFR 1633: after the effective date. Presentation at American Home Furnishings Alliance Flammability Workshop March 20 2008http://www.cpsc.gov/library/foia/foia08/os/ahfa2.pdf[accessed 04/25/2011].
18. 10.1002/(SICI)1099-1018(199701)21:1<17::AID-FAM590>3.0.CO;2-G10.1002/(SICI)1099-1018(199701)21:1<17::AID-FAM590>3.0.CO;2-G ↗
19. 10.1016/S0141-3910(02)00036-810.1016/S0141-3910(02)00036-8 ↗
20. 10.1016/j.polymertesting.2005.03.00110.1016/j.polymertesting.2005.03.001 ↗
21. 10.1002/fam.80710.1002/fam.807 ↗
22. LyonRE WaltersR.A microscale combustion calorimeter. DOT/FAA/AR‐01/117. Final Report.Federal Aviation Administration:Washington D.C. 2002 28.http://www.tc.faa.gov/its/worldpac/techrpt/ar01‐117.pdf[accessed 04/25/2011].
23. 10.1016/j.polymdegradstab.2009.11.04710.1016/j.polymdegradstab.2009.11.047 ↗
24. 10.1016/j.tca.2007.05.02110.1016/j.tca.2007.05.021 ↗
25. LinTS CogenJM LyonRE.Correlations between microscale combustion calorimetry and conventional flammability tests for flame retardant wire and cable compounds. InProceedings of the 58thInternational Wire & Cable Symposium International Wire & Cable Symposium Inc.:Eatontown NJ 2007;176–185.http://iwcs.omnibooksonline.com/[accessed 04/25/2011].
26. 10.1016/j.jaap.2011.01.01210.1016/j.jaap.2011.01.012 ↗
27. 10.1002/fam.79610.1002/fam.796 ↗
28. 10.1002/(SICI)1099–1018(19960310.1002/(SICI)1099–1018(199603 ↗
29. 10.1002/fam.106110.1002/fam.1061 ↗
30. 10.1002/(SICI)1099-1018(199703)21:2<95::AID-FAM601>3.0.CO;2-A10.1002/(SICI)1099-1018(199703)21:2<95::AID-FAM601>3.0.CO;2-A ↗