Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response
Source abstract
Abstract
Abstract Extremely low‐frequency (below 10 Hz) current‐induced magnetic field detection has significant applications in high‐voltage DC systems, lithium‐ion battery diagnostics, and industrial process monitoring. Nitrogen‐vacancy (NV) ensembles magnetometry typically employs flux concentrators to enhance magnetic detection sensitivity, but this enhancement comes at the cost of introducing more low‐frequency magnetic noise, such as the thermal magnetization noise of ferromagnetic materials, directly limiting their potential at low frequencies. Here, the enhancement of the signal‐to‐noise ratio (SNR) in extremely low‐frequency magnetic field detection within NV magnetometry, achieved via nonlinear response, is experimentally demonstrated. The approach enables the extension of the magnetic field detection bandwidth to the Hz range while simultaneously enhancing magnetic field sensitivity by using a magnetic flux concentrator. The magnetic field from the coil current, enhanced by the flux concentrator, drives NV ensembles into the nonlinear response region of the differential spectrum of the optically detected magnetic resonance (ODMR). Within this regime, nonlinear effects generate signal‐frequency mixing and 1/f noise suppression. By pre‐modulating the target signal at the driving frequency, its recovery through frequency mixing retains 1/f noise suppression, consequently enhancing SNR. For the 0.5 Hz signal, experimental results demonstrate up to a 2.6‐fold enhancement in SNR. This approach offers a new strategy for utilizing NV ensembles in extremely low‐frequency magnetic field detection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Atomic and Subatomic Physics Research · Magnetic Field Sensors Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Physics Hefei University of Technology Hefei Anhui 230009 China
Funding
National Natural Science Foundation of China · National Key Research and Development Program of China · China Postdoctoral Science Foundation · Fundamental Research Funds for the Central Universities
References (27)
Show source-provided references
1. 10.1002/wene.27810.1002/wene.278 ↗
2. 10.1109/TIM.2019.292251410.1109/TIM.2019.2922514 ↗
3. 10.1109/JSEN.2019.289249810.1109/JSEN.2019.2892498 ↗
4. 10.1038/srep3024810.1038/srep30248 ↗
5. 10.1149/07301.0161ecst10.1149/07301.0161ecst ↗
6. 10.1016/j.est.2023.11024010.1016/j.est.2023.110240 ↗
7. 10.1038/srep0809510.1038/srep08095 ↗
8. 10.3390/s2015419710.3390/s20154197 ↗
9. Xin M. · 2021 · 012114
10. 10.1049/iet-pel.2016.030410.1049/iet-pel.2016.0304 ↗
11. 10.1002/adsr.20240010610.1002/adsr.202400106 ↗
12. 10.1038/s41598-022-18106-x10.1038/s41598-022-18106-x ↗
13. 10.1063/5.017401610.1063/5.0174016 ↗
14. 10.1021/acs.nanolett.0c0337710.1021/acs.nanolett.0c03377 ↗
15. 10.1016/j.scib.2020.08.00110.1016/j.scib.2020.08.001 ↗
16. 10.1364/OE.48824310.1364/OE.488243 ↗
17. 10.1063/1.305615210.1063/1.3056152 ↗
18. 10.1063/1.288571110.1063/1.2885711 ↗
19. 10.1103/PhysRevResearch.2.02339410.1103/PhysRevResearch.2.023394 ↗
20. 10.1109/INTMAG.2006.37491410.1109/INTMAG.2006.374914 ↗
21. 10.3390/mi1505066210.3390/mi15050662 ↗
22. 10.1063/5.008990810.1063/5.0089908 ↗
23. 10.1063/1.503421610.1063/1.5034216 ↗
24. 10.1063/5.020510510.1063/5.0205105 ↗
25. 10.1103/PhysRevApplied.10.03404410.1103/PhysRevApplied.10.034044 ↗
26. 10.1364/PRJ.46285110.1364/PRJ.462851 ↗
27. 10.1021/nl404072s10.1021/nl404072s ↗