journal article·2012-01

Electromagnetic shielding characteristics of woven fabrics made of hybrid yarns containing metal wire

Huseyin Gazi Ortlek, Omer Galip Saracoglu, Oznur Saritas, Sinem Bilgin

Fibers and Polymers· Volume 13· Issue 1
Publisher page

Abstract

In this study, electromagnetic shielding characteristics of woven fabrics made of hybrid yarns are investigated. For this purpose, initially the hybrid yarns containing stainless steel wire are produced with hollow spindle covering technique, and then eight different fabric samples are produced using these hybrid yarns. Electromagnetic shielding values of fabric samples are determined by a test set up based on enclosure measurement technique. Measurements are made in the frequency range of 30 MHz-9.93 GHz. Test results show that woven fabric samples investigated in this study have 25–65 dB electromagnetic shielding effectiveness for incident frequency. It was also shown that the direction, density and settlement type of conductive hybrid yarn in fabric structure are important parameters affecting electromagnetic shielding characteristics of woven fabrics.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electromagnetic wave absorption materials · Advanced Antenna and Metasurface Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. J. S. Roh, Y. S. Chi, T. J. Kang, and S. W. Nam, Text. Res. J., 78, 825 (2008).10.1177/0040517507089748 ↗
2. K. Lai, R. J. Sun, M. Y. Chen, H. Wu, and A. X. Zha, Text. Res. J., 77, 242 (2007).10.1177/0040517507074033 ↗
3. C. I. Su and J. T. Chern, Text. Res. J., 74, 51 (2004).10.1177/004051750407400109 ↗
4. R. Perumalraj, B. S. Dasaradan, R. Anbarasu, P. Arokiaraj, and S. L. Harish, J. Text. Inst., 100, 512 (2009).10.1080/00405000801997587 ↗
5. K. B. Cheng, S. Ramakrishna, and K. C. Lee, Compos. Part A: Appl. Sci. Manufact., 31, 1039 (2000).10.1016/S1359-835X(00)00071-3 ↗
6. R. Perumalraj and B. S. Dasaradan, Fibers Text. East. Eur., 18, 74 (2010).
7. D. Soyaslan, S. Comlekci, and O. Goktepe, J. Text. Inst., 101, 890 (2010).10.1080/00405000902945360 ↗
8. R. Perumalraj, G. Nalankili, T. R. Balasaravanan, K. Roshanraja, G. Shyamsundar, and B. S. Dasaradan, Indian J. Fibre. Text. Res., 35, 361 (2010).
9. IEEE Standard 299-1997, IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures.
10. IEEE Standard 1302-1998 IEEE Guide for the Electromagnetic Characterization of Conductive Gaskets in the Frequency Range of DC to 18 GHz.