journal article·2017-01Open access

Highly Efficient Photoacoustic Conversion by Facilitated Heat Transfer in Ultrathin Metal Film Sandwiched by Polymer Layers

Taehwa Lee, L. Jay Guo

Advanced Optical Materials· Volume 5· Issue 2

Abstract

Photoacoustic (PA) conversion of metal film absorbers is known to be inefficient because of their low thermal expansion and high optical reflection, as compared to polymeric materials containing light absorbing fillers. Here, highly efficient PA conversion is demonstrated in metal films. By using a metal film absorber sandwiched by transparent polymer layers, PA conversion is significantly enhanced, which is even comparable to in the highest reported in the CNT‐polymer composites. Such enhancement is accomplished by ultrathin metal film (10 nm) capable of facilitating heat transfer to the adjacent polymers having high thermal expansion coefficient. This thin metal layer also allows integration of a photonic resonance cavity, effectively compensating the potential absorption loss of the thin metal. This strategy allows for easy spatial PA signal patterns and high conversion efficiency, which not only can be implemented for deep tissue PA imaging of implants or tools, but also provides a guideline for designing photoacoustic transmitters and contrast agents.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Nanoplatforms for cancer theranostics · Thermography and Photoacoustic Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering University of Michigan Ann Arbor Michigan 48109 USA

Department of Electrical Engineering and Computer Science University of Michigan Ann Arbor Michigan 48109 USA

Funding

National Science Foundation

References (29)

Show source-provided references
1. 10.1038/nbt83910.1038/nbt839 ↗
2. 10.1063/1.219502410.1063/1.2195024 ↗
3. Ball D. W. · Spectroscopy · 2006 · 21 · 14
4. 10.1201/978142005992210.1201/9781420059922 ↗
5. 10.1016/S0963-8695(00)00032-310.1016/S0963-8695(00)00032-3 ↗
6. 10.1364/OL.33.00092910.1364/OL.33.000929 ↗
7. 10.1063/1.138802710.1063/1.1388027 ↗
8. 10.1063/1.352283310.1063/1.3522833 ↗
9. 10.1063/1.487367810.1063/1.4873678 ↗
10. 10.1063/1.477249810.1063/1.4772498 ↗
11. 10.1063/1.493458710.1063/1.4934587 ↗
12. 10.1063/1.490565910.1063/1.4905659 ↗
13. 10.1364/JOSAB.29.00201610.1364/JOSAB.29.002016 ↗
14. 10.1038/srep0098910.1038/srep00989 ↗
15. 10.1002/jbio.20120024710.1002/jbio.201200247 ↗
16. 10.1364/BOE.4.00144210.1364/BOE.4.001442 ↗
17. 10.1103/PhysRevApplied.2.02400710.1103/PhysRevApplied.2.024007 ↗
18. 10.1063/1.234492910.1063/1.2344929 ↗
19. 10.1038/srep2151110.1038/srep21511 ↗
20. 10.1103/PhysRevB.92.11545010.1103/PhysRevB.92.115450 ↗
21. 10.1117/1.352801410.1117/1.3528014 ↗
22. 10.1063/1.477670110.1063/1.4776701 ↗
23. 10.1002/smll.20110114010.1002/smll.201101140 ↗
24. 10.1103/PhysRevApplied.3.04400710.1103/PhysRevApplied.3.044007 ↗
25. 10.1364/BOE.2.00224310.1364/BOE.2.002243 ↗
26. 10.1117/1.JBO.18.5.05600810.1117/1.JBO.18.5.056008 ↗
27. 10.1039/C5NR03769G10.1039/C5NR03769G ↗
28. 10.1103/PhysRevLett.86.355010.1103/PhysRevLett.86.3550 ↗
29. 10.1103/PhysRevLett.113.17430110.1103/PhysRevLett.113.174301 ↗