journal article·2025-02Open access

Magnetically Activated Ingestible Pill with Archimedes Screw for On‐Demand Sampling of Intestinal Microbiome

Aydin Sadeqi, Ruben Del‐Rio‐Ruiz, Hojatollah Rezaei Nejad, Jessica Resnick‐Sousa, Hannah Creasey, Olivia Goss, Cihan Asci, Giovanni Widmer, Sameer R. Sonkusale

Advanced Materials Technologies· Volume 10· Issue 3

Abstract

Abstract Technologies capable of noninvasively sampling different locations in the gut upstream of the colon will enable new insights into the role of organ‐specific microbiomes on human health. Herein, an ingestible pill for the sampling of gut lumen based on one of the earliest hydraulic machines known as an Archimedes screw is reported. The design contains twisted wires as Archimedes screw driven by a motor, wirelessly activated using a magnet. The sampling performance of the screw‐pump pill is characterized using realistic in vitro models and validated in vitro using E. coli expressing different fluorescent proteins. The use of the Archimedes screw enables the pill to sample the dense GI environment. The pill is also tested ex vivo in the pig intestine and in vivo in pigs. Herein, the results show that the bacterial populations recovered from the pill's chamber closely resemble the targeted bacterial population of the microenvironment to which the pill is exposed. Such ingestible devices have the potential to revolutionize the understanding of the spatial diversity of the gut microbiome and its response to medical conditions and treatments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Gut microbiota and health · Gastrointestinal motility and disorders · Cystic Fibrosis Research Advances

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Computer Engineering Tufts University 161 College Avenue Medford Massachusetts 02155 USA

Nanolab Advanced Technology Laboratory Tufts University Medford Massachusetts 02155 USA

Cummings School of Veterinary Medicine Tufts University North Grafton Massachusetts 01536 USA

Funding

National Institutes of Health · Office of Naval Research

References (47)

Show source-provided references
1. 10.1126/science.110481610.1126/science.1104816 ↗
2. 10.1146/annurev.nutr.22.011602.09225910.1146/annurev.nutr.22.011602.092259 ↗
3. 10.1038/nature0882110.1038/nature08821 ↗
4. 10.1016/j.giec.2016.08.00110.1016/j.giec.2016.08.001 ↗
5. 10.1038/nature0994410.1038/nature09944 ↗
6. 10.2217/17460913.2.3.28510.2217/17460913.2.3.285 ↗
7. 10.1038/nature1020810.1038/nature10208 ↗
8. 10.3390/nu408109510.3390/nu4081095 ↗
9. 10.1177/15648265130340030810.1177/156482651303400308 ↗
10. 10.1016/j.chom.2014.02.00510.1016/j.chom.2014.02.005 ↗
11. 10.1016/j.tim.2012.04.00110.1016/j.tim.2012.04.001 ↗
12. 10.1016/j.addr.2020.05.00410.1016/j.addr.2020.05.004 ↗
13. 10.1016/j.snb.2021.13078110.1016/j.snb.2021.130781 ↗
14. 10.1002/jps.2427410.1002/jps.24274 ↗
15. 10.1038/s41578-018-0070-310.1038/s41578-018-0070-3 ↗
16. 10.1016/j.addr.2021.11385310.1016/j.addr.2021.113853 ↗
17. 10.1007/s00604-023-05946-110.1007/s00604-023-05946-1 ↗
18. 10.1002/aisy.20190005310.1002/aisy.201900053 ↗
19. 10.1039/C9RA10986B10.1039/C9RA10986B ↗
20. 10.1016/j.actbio.2022.09.05010.1016/j.actbio.2022.09.050 ↗
21. 10.1002/aisy.20220003010.1002/aisy.202200030 ↗
22. 10.1016/j.device.2024.10040610.1016/j.device.2024.100406 ↗
23. 10.1002/admt.20230081010.1002/admt.202300810 ↗
24. 10.1038/s41467-024-46046-910.1038/s41467-024-46046-9 ↗
25. 10.1016/j.biosx.2023.10038010.1016/j.biosx.2023.100380 ↗
26. 10.1109/TBME.2023.334333710.1109/TBME.2023.3343337 ↗
27. 10.1016/j.addr.2021.11393110.1016/j.addr.2021.113931 ↗
28. 10.1115/1.405525010.1115/1.4055250 ↗
29. 10.1038/s41586-023-05989-710.1038/s41586-023-05989-7 ↗
30. 10.1038/nrmicro355210.1038/nrmicro3552 ↗
31. 10.1038/s41598-020-71939-210.1038/s41598-020-71939-2 ↗
32. 10.1016/j.bbrc.2022.06.06110.1016/j.bbrc.2022.06.061 ↗
33. 10.1371/journal.pone.013411610.1371/journal.pone.0134116 ↗
34. 10.1136/gutjnl-2020-32246510.1136/gutjnl-2020-322465 ↗
35. 10.1109/TMECH.2022.315553410.1109/TMECH.2022.3155534 ↗
36. 10.1016/j.device.2024.10043810.1016/j.device.2024.100438 ↗
37. 10.3138/978148757792610.3138/9781487577926 ↗
38. 10.1016/j.rser.2015.06.02810.1016/j.rser.2015.06.028 ↗
39. 10.3826/jhr.2009.347510.3826/jhr.2009.3475 ↗
40. A. M.Bourhis E. L.Miller S. R.Sonkusale in2017 IEEE 60th International Midwest Symposium on Circuits and Systems (MWSCAS) IEEE New Jersey USA 2017 pp.1280–1283.10.1109/MWSCAS.2017.8053164 ↗
41. 10.1109/TBME.2014.235249310.1109/TBME.2014.2352493 ↗
42. 10.1038/s41551-017-0129-210.1038/s41551-017-0129-2 ↗
43. 10.1109/RBME.2011.217118210.1109/RBME.2011.2171182 ↗
44. 10.1155/2012/80716510.1155/2012/807165 ↗
45. 10.1038/s41598-020-77129-410.1038/s41598-020-77129-4 ↗
46. https://www.medtronic.com/(accessed December 2023).
47. 10.1128/AEM.01541-0910.1128/AEM.01541-09 ↗