An Intrinsically Conductive Elastomer for Thromboembolism Diagnosis
Source abstract
Abstract
Abstract As a minimally invasive procedure, balloon dilation is one crucial means to assist the delivery of stent and anti‐hyperplasia drugs to the embolism sites in the typical endovascular interventional treatments. However, it is rarely noted that the degree of balloon dilation is blurry, though it is extremely important to the efficiency of stent implantation, drug delivery, and even the postoperative recurrence rate of embolism. Herein, an innovative strategy of applying the balloon itself as an electrical sensor to monitor the dilation process is conceived. An intrinsically conductive elastomer formulated with polyurethane and potassium chloride is exploited as the biocompatible balloon, which integrates sufficient mechanical endurance, conductivity, biocompatibility, and pressure sensitivity against balloon expansion comprehensively. As a practical demonstration, the balloon sensor has been successfully applied to detect thrombus in tubular channels via real‐time pressure and temperature monitoring, which is anticipated to open an avenue to examine and treat cardiovascular diseases with a more controllable and reliable procedure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Conducting polymers and applications · Advanced Sensor and Energy Harvesting Materials · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Chemistry Renmin University of China Beijing 100872 China
Funding
National Natural Science Foundation of China
References (43)
Show source-provided references
1. 10.1182/blood-2008-01-07790910.1182/blood-2008-01-077909 ↗
2. 10.1186/s13019-019-0974-z10.1186/s13019-019-0974-z ↗
3. 10.1161/STROKEAHA.116.01310510.1161/STROKEAHA.116.013105 ↗
4. 10.1039/C7TB02162C10.1039/C7TB02162C ↗
5. 10.1016/j.echo.2015.09.01110.1016/j.echo.2015.09.011 ↗
6. 10.1007/5584_2016_11610.1007/5584_2016_116 ↗
7. Casana R. · Catheter. Cardiovasc. Interventions · 2019 · 1 · 7
8. 10.1002/adma.20180545210.1002/adma.201805452 ↗
9. 10.1007/s00270-012-0365-510.1007/s00270-012-0365-5 ↗
10. 10.3171/2009.2.JNS0849110.3171/2009.2.JNS08491 ↗
11. 10.4103/0028-3886.14124110.4103/0028-3886.141241 ↗
12. 10.1126/scirobotics.aax732910.1126/scirobotics.aax7329 ↗
13. 10.1002/adma.20150415010.1002/adma.201504150 ↗
14. 10.1039/C8TC02230E10.1039/C8TC02230E ↗
15. Gao N. · Chem. J. Chin. Univ. · 2020 · 41 · 901
16. 10.1002/adfm.20180638810.1002/adfm.201806388 ↗
17. 10.1002/adfm.20180824710.1002/adfm.201808247 ↗
18. 10.1021/acssensors.7b0023010.1021/acssensors.7b00230 ↗
19. 10.1126/sciadv.150066110.1126/sciadv.1500661 ↗
20. 10.1039/D0MH00089B10.1039/D0MH00089B ↗
21. 10.1002/adma.20200021810.1002/adma.202000218 ↗
22. Han J. · Chemistry · 2017 · 80 · 123
23. 10.1002/smll.20130264610.1002/smll.201302646 ↗
24. 10.1021/acssensors.5b0019510.1021/acssensors.5b00195 ↗
25. 10.1002/adfm.20191054110.1002/adfm.201910541 ↗
26. 10.1039/C8TC04699A10.1039/C8TC04699A ↗
27. 10.1002/adma.20190298710.1002/adma.201902987 ↗
28. Hou Y. · Adv. Mater. · 2020 · 5 · 2000249
29. 10.1021/acs.langmuir.8b0212510.1021/acs.langmuir.8b02125 ↗
30. 10.3762/bjnano.7.10910.3762/bjnano.7.109 ↗
31. 10.1021/nn100883p10.1021/nn100883p ↗
32. 10.3144/expresspolymlett.2010.6510.3144/expresspolymlett.2010.65 ↗
33. 10.1016/j.carbon.2005.11.00710.1016/j.carbon.2005.11.007 ↗
34. 10.1021/acsmacrolett.9b0017910.1021/acsmacrolett.9b00179 ↗
35. 10.1039/C8CC05410J10.1039/C8CC05410J ↗
36. 10.1002/(SICI)1521-4095(199804)10:6<439::AID-ADMA439>3.0.CO;2-I10.1002/(SICI)1521-4095(199804)10:6<439::AID-ADMA439>3.0.CO;2-I ↗
37. 10.1039/C8ME00096D10.1039/C8ME00096D ↗
38. 10.1039/C9TA03661J10.1039/C9TA03661J ↗
39. 10.1021/acssensors.8b0024910.1021/acssensors.8b00249 ↗
40. Du Y. · Exp. Ther. Med. · 2019 · 17 · 3222
41. 10.1002/adfm.20190070310.1002/adfm.201900703 ↗
42. 10.1016/j.jcmg.2014.05.00910.1016/j.jcmg.2014.05.009 ↗
43. 10.5853/jos.2016.0090610.5853/jos.2016.00906 ↗