journal article·2020-08

Towards a Chipless and Wireless Passive System for Real‐Time Encoding of the Bladder Volume

Filippo Melloni, Giorgio E. Bonacchini, Guglielmo Lanzani, Mario Caironi

Advanced Materials Technologies· Volume 5· Issue 8
Publisher page

Abstract

Abstract Neurogenic bladder and other lower urinary tract dysfunctions represent a significant health hazard and life‐quality impairment in individuals suffering from neurological disorders. A few implantable and wearable technologies have been proposed to partially recover bladder functionality, mostly based on resistive and capacitive strain gauges designed to be surgically placed inside the pelvic cavity. In this work, an alternative proof‐of‐concept device for monitoring the volumetric changes of the bladder is presented, where the sensing element is based on a capacitive linear encoder integrated with a passive wireless radio‐frequency resonator, which can be remotely interrogated. The sliding mechanism at the core of the proposed system allows a wide sensing range without stringent requirements on materials properties and overall device stability.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Urinary Bladder and Prostate Research · Tissue Engineering and Regenerative Medicine · Kidney Stones and Urolithiasis Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Center for Nano Science and Technology @PoliMi Istituto Italiano di Tecnologia Via Giovanni Pascoli, 70/3 Milano 20133 Italy

Department of Electronics Information and Bioengineering Politecnico di Milano Piazza Leonardo da Vinci, 32 Milano 20133 Italy

Department of Physics Politecnico di Milano Piazza Leonardo da Vinci, 32 Milano 20133 Italy

References (34)

Show source-provided references
1. 10.1016/S1474-4422(15)00070-810.1016/S1474-4422(15)00070-8 ↗
2. 10.1089/neu.2011.222610.1089/neu.2011.2226 ↗
3. 10.1016/j.mpmed.2007.05.00910.1016/j.mpmed.2007.05.009 ↗
4. 10.1111/j.1464-410X.2006.06395.x10.1111/j.1464-410X.2006.06395.x ↗
5. 10.1007/s11884-015-0323-610.1007/s11884-015-0323-6 ↗
6. 10.1016/j.ucl.2017.04.00110.1016/j.ucl.2017.04.001 ↗
7. 10.1038/nrurol.2010.19010.1038/nrurol.2010.190 ↗
8. 10.1007/s00467-007-0691-z10.1007/s00467-007-0691-z ↗
9. 10.1126/scitranslmed.300718610.1126/scitranslmed.3007186 ↗
10. 10.5213/inj.2015.19.3.13310.5213/inj.2015.19.3.133 ↗
11. 10.1097/SPV.000000000000056510.1097/SPV.0000000000000565 ↗
12. 10.1109/TBME.2014.231802310.1109/TBME.2014.2318023 ↗
13. 10.1145/2180878.218088310.1145/2180878.2180883 ↗
14. 10.1016/j.jbiomech.2006.02.01410.1016/j.jbiomech.2006.02.014 ↗
15. 10.1038/nrurol.2018.510.1038/nrurol.2018.5 ↗
16. Cao H. · 2013
17. Kim M. K. · Sensors (Switzerland) · 2018 · 18 · 1
18. 10.1002/admt.20180003110.1002/admt.201800031 ↗
19. 10.1142/S233954781640008210.1142/S2339547816400082 ↗
20. Ramakrishnan V. M. · 2020 · 5
21. 10.1021/acsomega.8b0260910.1021/acsomega.8b02609 ↗
22. 10.1016/j.pmatsci.2012.09.00110.1016/j.pmatsci.2012.09.001 ↗
23. 10.1002/jbm.b.3158410.1002/jbm.b.31584 ↗
24. Schneider A. · 2017 · 7
25. Laqua D. · 2010 · 1437
26. Vaillancourt P. · Proc. of the 19th Annu. Int. Conf. of the IEEE Eng. in Med. and Biol. Society · 1997 · 6 · 2499
27. Freudenthal E. · Evaluation Of HF RFID for Implanted Medical Applications · 2007
28. 10.1152/jappl.2000.89.3.96710.1152/jappl.2000.89.3.967 ↗
29. 10.1002/elan.20160065310.1002/elan.201600653 ↗
30. Asogwa C. O. · 2016 · 552
31. 10.3390/s808508110.3390/s8085081 ↗
32. 10.1002/047165376410.1002/0471653764 ↗
33. 10.1063/1.174664510.1063/1.1746645 ↗
34. Drake R. L. · 2015