journal article·2023-09Open access

Bidirectional Venturi Flowmeter Based on Capacitive Sensors for Spirometry

Laura L. Becerra, Tarek Rafeedi, Sankaran Ramanarayanan, Ian Frankel, Juliana Miller, Alexander X. Chen, Yi Qie, Darren J. Lipomi, Harinath Garudadri, Tse Nga Ng

Advanced Materials Technologies· Volume 8· Issue 18

Abstract

Abstract In this work, a portable venturi tube capable of measuring bidirectional respiratory flow is developed and correlated the measurements to pulmonary function. Pressure signals are transduced using flexible and compressible capacitive foam sensors embedded into the wall of the device. In this configuration, the sensors are able to provide differential pressure readings, from which the airflow rate passing through the tube could be extrapolated. Utilizing the venturi effect, the geometry of the spirometer tube is designed through finite element analysis to measure respiratory airflow during inhalation and exhalation. The device tube is 3D‐printed and used to measure tidal breathing and deep breathing, along with peak expiratory flow rates, on a healthy individual. This spirometer design allows for easy‐to‐use point‐of‐care diagnoses and has the potential to improve the care of respiratory illnesses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Respiratory Support and Mechanisms · Inhalation and Respiratory Drug Delivery · Chronic Obstructive Pulmonary Disease (COPD) Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Computer Engineering University of California San Diego 92093 USA

Department of Nano and Chemical Engineering University of California San Diego 92093 USA

Department of Mechanical and Aerospace Engineering University of California San Diego 92093 USA

Qualcomm Institute University of California 9500 Gilman Drive, La Jolla San Diego CA 92093‐0448 USA

Funding

U.S. Department of Defense · National Defense Science and Engineering Graduate · National Science Foundation

References (43)

Show source-provided references
1. 10.1016/j.rmed.2019.08.00410.1016/j.rmed.2019.08.004 ↗
2. 10.1378/chest.06-272210.1378/chest.06-2722 ↗
3. M.McCormack D.Kaminsky https://www.thoracic.org/professionals/clinical‐resources/disease‐related‐resources/pulmonary‐function‐laboratories.php(accessed: August 2022).
4. 10.1164/rccm.201908-1590ST10.1164/rccm.201908-1590ST ↗
5. 10.1007/s12098-017-2398-x10.1007/s12098-017-2398-x ↗
6. Patil R. · Natl. J. Physiol., Pharm. Pharmacol. · 2020 · 10 · 508
7. 10.3390/diagnostics903010010.3390/diagnostics9030100 ↗
8. 10.3109/02770903.2014.95689010.3109/02770903.2014.956890 ↗
9. 10.1378/chest.111.3.55910.1378/chest.111.3.559 ↗
10. 10.3390/s1708185310.3390/s17081853 ↗
11. 10.1016/j.mee.2020.11128610.1016/j.mee.2020.111286 ↗
12. 10.1109/JSEN.2019.291959910.1109/JSEN.2019.2919599 ↗
13. 10.1109/JSEN.2022.317031410.1109/JSEN.2022.3170314 ↗
14. C. W.Carspecken C.Arteta G. D.Clifford B.Engineering E.Science Harvard Medical School Boston MA United States. Point‐of‐Care Healthcare Technologies (PHT) 2013 IEEE2013 16.
15. 10.3390/proceedings213150910.3390/proceedings2131509 ↗
16. Zhou B. · Sensors (Switzerland) · 2020 · 20 · 1
17. 10.1016/j.nanoen.2019.10395310.1016/j.nanoen.2019.103953 ↗
18. 10.1021/acsnano.8b0256210.1021/acsnano.8b02562 ↗
19. 10.1016/j.egyr.2020.08.04210.1016/j.egyr.2020.08.042 ↗
20. R.Carta D.Turgis B.Hermans P.Jourand R.Onclin R.Puers K. U.Leuven Conference Proceedings – IEEE Biomedical Circuits and Systems Conference Healthcare Technology BiOCAS20072007 5.
21. P.Sridevi P.Kundu T.Islam C.Shahnaz S. A.Fattah IEEE Region 10 Annual International Conference Proceedings/TENCON2019 2018‐Octob (October) 723.
22. 10.1063/1.499144110.1063/1.4991441 ↗
23. 10.1016/j.apt.2020.02.01110.1016/j.apt.2020.02.011 ↗
24. 10.1016/j.mpaic.2017.10.01010.1016/j.mpaic.2017.10.010 ↗
25. 10.1121/1.190189310.1121/1.1901893 ↗
26. 10.1016/j.resuscitation.2010.11.01610.1016/j.resuscitation.2010.11.016 ↗
27. 10.1016/j.flowmeasinst.2020.10172510.1016/j.flowmeasinst.2020.101725 ↗
28. 10.1016/j.mpaic.2009.10.01010.1016/j.mpaic.2009.10.010 ↗
29. Rapp B. E. F. In · 2017 · 24310.1016/B978-1-4557-3141-1.50009-5 ↗
30. S.Cortés D.Güemes R.Ávila Low Reynolds COMSOL Conference2013 1–7.
31. 10.1016/j.jestch.2016.06.01210.1016/j.jestch.2016.06.012 ↗
32. Hermann Schlichting · 1979
33. N. D.Katopodes 2019 https://doi.org/10.1016/b978‐0‐12‐815489‐2.00005‐8.
34. 10.1183/20734735.00981710.1183/20734735.009817 ↗
35. 10.1002/adma.20200254110.1002/adma.202002541 ↗
36. 10.1016/j.snb.2019.12737110.1016/j.snb.2019.127371 ↗
37. 10.1016/j.procs.2016.05.39210.1016/j.procs.2016.05.392 ↗
38. 10.1088/1752-7163/ac258910.1088/1752-7163/ac2589 ↗
39. 10.1016/j.flowmeasinst.2020.10172510.1016/j.flowmeasinst.2020.101725 ↗
40. Lofrese J. J. · 2022
41. Singh Gambhir R. · J. Clin. Diagn. Res. · 2013 · 7 · 3107
42. 10.1136/thx.53.11.94410.1136/thx.53.11.944 ↗
43. Çengel Y. A. · 2018