Mucosa‐Interfacing Capsule for In Situ Sensing the Elasticity of Biological Tissues
Source abstract
Abstract
Abstract Monitoring the elasticity of soft biological tissues in the gastrointestinal (GI) tract with minimal invasion holds promise for early diagnosis of intestinal fibrosis, colorectal cancer, and other diseases featuring abnormal elasticity. However, existing methods of sensing tissue elasticity have drawbacks such as insufficient resolution for elastography, and discomfort or the requirement of risky anesthesia for flexible endoscopes or implantable devices. Here a wirelessly actuated palpation mechanism is presented, integrated into a swallowable capsule device, offering in situ tissue elasticity measurement with minimal invasiveness. The approach employs a magnetic soft cantilever beam actuated by external magnetic fields to gently press against soft tissues. Mechanical stress and strain are monitored by an onboard magnetic sensor and a strain gauge, allowing for an accurate assessment of tissue elasticity. Additionally, wireless modules utilizing Bluetooth Low Energy (LE) and powered by a battery facilitate real‐time communication. The device operates under external magnetic field control, which can move freely over soft tissues during examinations and palpate suspicious areas. The elasticity sensing mechanism is validated and assessed on both phantom structures and ex vivo porcine colon tissues. The capsule device holds significant promise for assessing tissue physiological conditions and facilitating early disease diagnosis in hard‐to‐reach areas of the body.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · 3D Printing in Biomedical Research · Hydrogels: synthesis, properties, applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering Vanderbilt University Nashville TN 37212 USA
Department of Biomedical Engineering Vanderbilt University Nashville TN 37212 USA
Department of Mechanical Engineering Texas A&M University College Station TX 77843 USA
Department of Electrical and Computer Engineering Vanderbilt University Nashville TN 37212 USA
School of Medicine Vanderbilt University Nashville TN 37240 USA
Funding
Vanderbilt University
References (45)
Show source-provided references
1. 10.1038/s44222-023-00144-310.1038/s44222-023-00144-3 ↗
2. 10.1097/MIB.0b013e318281329710.1097/MIB.0b013e3182813297 ↗
3. 10.1016/j.actbio.2021.06.01110.1016/j.actbio.2021.06.011 ↗
4. 10.1038/s41575-021-00543-010.1038/s41575-021-00543-0 ↗
5. Baidoun F. · Curr. Drug Targets · 2020 · 22 · 998
6. 10.1038/s41578-019-0169-110.1038/s41578-019-0169-1 ↗
7. 10.1038/s41551-020-00657-x10.1038/s41551-020-00657-x ↗
8. 10.1038/s41598-019-55687-610.1038/s41598-019-55687-6 ↗
9. 10.1038/s41578-022-00477-210.1038/s41578-022-00477-2 ↗
10. 10.1016/j.sna.2014.12.02210.1016/j.sna.2014.12.022 ↗
11. S.McKinley A.Garg S.Sen R.Kapadia A.Murali K.Nichols S.Lim S.Patil P.Abbeel A. M.Okamura K.Goldberg presented atIEEE Int. Conf. on Automat. Sci. and Eng. 2015 Oct2015.
12. 10.1038/s42254-022-00543-210.1038/s42254-022-00543-2 ↗
13. 10.1007/s10620-021-07311-910.1007/s10620-021-07311-9 ↗
14. 10.1038/s41551-021-00723-y10.1038/s41551-021-00723-y ↗
15. 10.1038/s41551-018-0201-610.1038/s41551-018-0201-6 ↗
16. 10.1038/s41578-022-00427-y10.1038/s41578-022-00427-y ↗
17. 10.1109/JPROC.2022.316571310.1109/JPROC.2022.3165713 ↗
18. 10.1002/adfm.20230775110.1002/adfm.202307751 ↗
19. 10.1126/sciadv.adg398810.1126/sciadv.adg3988 ↗
20. 10.1002/mp.1229910.1002/mp.12299 ↗
21. 10.1002/adtp.20190012510.1002/adtp.201900125 ↗
22. 10.1007/s12213-016-0087-x10.1007/s12213-016-0087-x ↗
23. 10.1016/j.device.2023.10012510.1016/j.device.2023.100125 ↗
24. 10.1126/science.aas931510.1126/science.aas9315 ↗
25. 10.1002/adhm.20230289710.1002/adhm.202302897 ↗
26. 10.1038/s41578-018-0070-310.1038/s41578-018-0070-3 ↗
27. 10.1016/j.triboint.2015.12.03410.1016/j.triboint.2015.12.034 ↗
28. 10.1109/TRO.2018.288521810.1109/TRO.2018.2885218 ↗
29. X.Dong M.Sitti presented at2017 IEEE Int. Conf. Robot. Automat. (ICRA)SingaporeJune2017 pp6612.
30. 10.1038/s41598-019-56847-410.1038/s41598-019-56847-4 ↗
31. 10.3748/wjg.v28.i12.128410.3748/wjg.v28.i12.1284 ↗
32. 10.1126/sciadv.abc174610.1126/sciadv.abc1746 ↗
33. 10.1038/s41551-022-00873-710.1038/s41551-022-00873-7 ↗
34. 10.1038/s41551-016-002210.1038/s41551-016-0022 ↗
35. 10.1021/acsami.2c0966710.1021/acsami.2c09667 ↗
36. 10.1126/sciadv.adp275810.1126/sciadv.adp2758 ↗
37. 10.1089/soro.2018.017110.1089/soro.2018.0171 ↗
38. 10.1002/adhm.20240237310.1002/adhm.202402373 ↗
39. 10.1002/adfm.20240586510.1002/adfm.202405865 ↗
40. 10.1155/2012/51871810.1155/2012/518718 ↗
41. 10.4253/wjge.v5.i11.55910.4253/wjge.v5.i11.559 ↗
42. 10.1177/027836491455800610.1177/0278364914558006 ↗
43. 10.1039/C5LC00009B10.1039/C5LC00009B ↗
44. 10.1073/pnas.230830112010.1073/pnas.2308301120 ↗
45. 10.1016/0020-7225(65)90019-410.1016/0020-7225(65)90019-4 ↗