A Magnetically Coupled Dielectric Elastomer Pump for Soft Robotics
Source abstract
Abstract
Abstract Fluidic elastomer actuators have become ubiquitous in soft robotics as they can be used to create inherently compliant systems with embodied intelligence. However, they typically use conventional rigid air‐compression systems that restrict their application in untethered mobile and wearable devices. An embeddable pneumatic diaphragm pump is presented for soft robotics driven by a magnetically coupled dielectric elastomer actuator (MCDEA). The MCDEA pump exploits a compliant coupling between membranes to resonate at high power and efficiency despite the damping effects of the pneumatic chamber and valves. The MCDEA pump demonstrates an attractive dynamic performance with a peak stroke at resonance of over 800% of that at low frequencies, which corresponds to a maximum output pressure of 30.5 mbar and a flowrate of 0.9 L min−1 at a relatively low power consumption of 40 mW. The performance of this pneumatic pump design is demonstrated by integrating it with several soft robotic prototypes, including a soft gripper, ballooning chamber, and a suction cup. It shows considerable promise for driving the next generation of fully compliant and untethered soft robots.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Soft Robotics and Applications · Advanced Sensor and Energy Harvesting Materials · Micro and Nano Robotics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Bristol Soft Lab Bristol Robotics Laboratory Bristol BS16 1QY UK
Department of Aerospace Engineering University of Bristol Bristol BS8 1TR UK
Department of Mechanical Engineering University of Bristol Bristol BS8 1TR UK
Funding
Engineering and Physical Sciences Research Council
References (30)
Show source-provided references
1. 10.1038/nature1454310.1038/nature14543 ↗
2. 10.1038/s41928-018-0024-110.1038/s41928-018-0024-1 ↗
3. 10.1126/scirobotics.aah369010.1126/scirobotics.aah3690 ↗
4. 10.3389/fbioe.2014.0000310.3389/fbioe.2014.00003 ↗
5. 10.1089/soro.2014.000110.1089/soro.2014.0001 ↗
6. 10.1002/adma.20150307810.1002/adma.201503078 ↗
7. 10.1073/pnas.111656410810.1073/pnas.1116564108 ↗
8. 10.1016/j.robot.2014.08.01410.1016/j.robot.2014.08.014 ↗
9. 10.1089/soro.2013.000210.1089/soro.2013.0002 ↗
10. 10.1089/soro.2014.000810.1089/soro.2014.0008 ↗
11. 10.1088/0960-1317/14/6/R0110.1088/0960-1317/14/6/R01 ↗
12. Stergiopulos C. · 2014
13. 10.1007/s00422-012-0471-010.1007/s00422-012-0471-0 ↗
14. 10.1117/3.54746510.1117/3.547465 ↗
15. 10.1126/science.287.5454.83610.1126/science.287.5454.836 ↗
16. 10.1002/adfm.20140394210.1002/adfm.201403942 ↗
17. Poulin A. · 2016 · 97980L
18. 10.1002/adma.20150426410.1002/adma.201504264 ↗
19. 10.1002/admt.20180037810.1002/admt.201800378 ↗
20. 10.1002/adfm.20110125310.1002/adfm.201101253 ↗
21. 10.1126/science.124022810.1126/science.1240228 ↗
22. 10.1088/1361-665X/aac30210.1088/1361-665X/aac302 ↗
23. 10.1088/0964-1726/22/10/10401310.1088/0964-1726/22/10/104013 ↗
24. 10.1063/1.498582710.1063/1.4985827 ↗
25. 10.1039/b605525g10.1039/b605525g ↗
26. 10.1063/1.507143910.1063/1.5071439 ↗
27. Cao C. · 2018
28. Smart Products USA Inc. Model #101 1/8” check valve http://www.smartproducts.com/check_valves_series_100_cartridge_specialty.php(accessed: March2019).
29. 10.1098/rsif.2017.039510.1098/rsif.2017.0395 ↗
30. 10.1088/0964-1726/21/3/03501210.1088/0964-1726/21/3/035012 ↗