A Trisymmetric Magnetic Microchip Surface for Free and Two‐Way Directional Movement of Magnetic Microbeads
Source abstract
Abstract
Abstract The guidance of labeled microcarriers in microfluidic environments is a prerequisite to the development of magnetic pattern assisted lab‐on‐chip technology. Square wave modulations of in‐plane applied magnetic fields enable the forward and backward locomotion of superparamagnetic microspheres on discrete hexagonally arranged ferromagnetic structures in a flowless microfluidic environment at a single bead level. By using distinct magnetic field sequences, selective directional transportation and two‐way separational motion of different ensembles of beads across a varying stray magnetic field pattern is achieved. Microbeads can be moved along different directions along spatial microcorridors. The demonstrated realization of multifunctional patterned magnetic surfaces enables the controlled positioning and sorting of mixed populations of functionalized microcarriers for biodiagnostic applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · Micro and Nano Robotics · Electrowetting and Microfluidic Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute for Materials Science Kiel University Kaiserstraße 2 D‐24143 Kiel Germany
Funding
Deutsche Forschungsgemeinschaft
References (33)
Show source-provided references
1. 10.1088/1361-6463/50/3/03300210.1088/1361-6463/50/3/033002 ↗
2. 10.1039/B513005K10.1039/B513005K ↗
3. Rampini S. · Lab Chip · 2016 · 327 · 1072
4. 10.1119/1.143297110.1119/1.1432971 ↗
5. 10.1002/adma.20040188010.1002/adma.200401880 ↗
6. 10.1063/1.300919710.1063/1.3009197 ↗
7. 10.1038/ncomms484610.1038/ncomms4846 ↗
8. 10.1039/b919893h10.1039/b919893h ↗
9. 10.1002/adma.20110326410.1002/adma.201103264 ↗
10. 10.1088/1361-6463/aa5cef10.1088/1361-6463/aa5cef ↗
11. 10.1016/j.bpj.2009.10.03610.1016/j.bpj.2009.10.036 ↗
12. 10.1039/b713547e10.1039/b713547e ↗
13. 10.1103/PhysRevE.84.01140310.1103/PhysRevE.84.011403 ↗
14. 10.1103/PhysRevE.85.04140710.1103/PhysRevE.85.041407 ↗
15. 10.1039/C5LC00581G10.1039/C5LC00581G ↗
16. 10.1103/PhysRevLett.103.12810110.1103/PhysRevLett.103.128101 ↗
17. 10.1088/0957-4484/20/38/38550110.1088/0957-4484/20/38/385501 ↗
18. 10.1002/adma.20100014610.1002/adma.201000146 ↗
19. 10.1039/c1lc20300b10.1039/c1lc20300b ↗
20. 10.1039/c2lc40715a10.1039/c2lc40715a ↗
21. 10.1103/PhysRevB.87.17442610.1103/PhysRevB.87.174426 ↗
22. 10.1002/adma.20130424010.1002/adma.201304240 ↗
23. 10.1021/acsnano.6b0356610.1021/acsnano.6b03566 ↗
24. 10.1063/1.470452010.1063/1.4704520 ↗
25. 10.1039/C6CP05599K10.1039/C6CP05599K ↗
26. 10.1038/s41598-017-10149-910.1038/s41598-017-10149-9 ↗
27. 10.1159/00035830610.1159/000358306 ↗
28. micromer‐M www.micromod.de(accessed: April2017).
29. 10.1002/1521-3951(199712)204:2<817::AID-PSSB817>3.0.CO;2-D10.1002/1521-3951(199712)204:2<817::AID-PSSB817>3.0.CO;2-D ↗
30. 10.1088/0022-3727/48/33/33300110.1088/0022-3727/48/33/333001 ↗
31. 10.1038/nmeth.208910.1038/nmeth.2089 ↗
32. 10.1002/pssa.221137011810.1002/pssa.2211370118 ↗
33. 10.1109/20.61969810.1109/20.619698 ↗