journal article·2016-09Open access

Depth-Resolved Full-Field Measurement of Corneal Deformation by Optical Coherence Tomography and Digital Volume Correlation

J. Fu, M. Haghighi-Abayneh, F. Pierron, P. D. Ruiz

Experimental Mechanics· Volume 56· Issue 7

Abstract

The study of vertebrate eye cornea is an interdisciplinary subject and the research on its mechanical properties has significant importance in ophthalmology. The measurement of depth-resolved 3D full-field deformation behaviour of cornea under changing intraocular pressure is a useful method to study the local corneal mechanical properties. In this work, optical coherence tomography was adopted to reconstruct the internal structure of a porcine cornea inflated from 15 to 18.75 mmHg (close to the physical porcine intraocular pressure) in the form of 3D image sequences. An effective method has been developed to correct the commonly seen refraction induced distortions in the optical coherence tomography reconstructions, based on Fermat’s principle. The 3D deformation field was then determined by performing digital volume correlation on these corrected 3D reconstructions. A simple finite element model of the inflation test was developed and the predicted values were compared against digital volume correlation results, showing good overall agreement.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal surgery and disorders · Optical Coherence Tomography Applications · Glaucoma and retinal disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Atchison DA, Smith G (2000) Chapter 2—Refracting components: cornea and lens. In: Smith DAA (ed) Optics of the human eye. Butterworth-Heinemann, Edinburgh, pp 11–2010.1016/B978-0-7506-3775-6.50006-7 ↗
2. Fatt I, Weissman BA (1992) Physiology of the eye, 2nd edn. Butterworth-Heinemann, Edinburgh, pp 97–14910.1016/B978-0-7506-9085-0.50010-1 ↗
3. Browning AC et al (2004) The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Br J Ophthalmol 88(11):1395–139910.1136/bjo.2003.037887 ↗
4. Krachmer JH, Feder RS, Belin MW (1984) Keratoconus and related noninflammatory corneal thinning disorders. Surv Ophthalmol 28(4):293–32210.1016/0039-6257(84)90094-8 ↗
5. Notara M et al (2010) In sickness and in health: corneal epithelial stem cell biology, pathology and therapy. Exp Eye Res 90(2):188–19510.1016/j.exer.2009.09.023 ↗
6. Robin JB et al (1986) Peripheral corneal disorders. Surv Ophthalmol 31(1):1–3610.1016/0039-6257(86)90049-4 ↗
7. Tarkkanen A, Merenmies L (2001) Corneal pathology and outcome of keratoplasty in autoimmune polyendocrinopathy-candidiasis-ectodermal dystrophy (APECED). Acta Ophthalmol Scand 79(2):204–20710.1034/j.1600-0420.2001.079002204.x ↗
8. De Paiva CS et al (2006) The incidence and risk factors for developing dry eye after myopic LASIK. Am J Ophthalmol 141(3):438–44510.1016/j.ajo.2005.10.006 ↗
9. Asejczyk-Widlicka M et al (2011) Material properties of the cornea and sclera: a modelling approach to test experimental analysis. J Biomech 44(3):543–54610.1016/j.jbiomech.2010.09.032 ↗
10. Bryant MR, McDonnell PJ (1996) Constitutive laws for biomechanical modeling of refractive surgery. J Biomech Eng 118(4):473–48110.1115/1.2796033 ↗
11. Kwon TH et al (2008) Effect of cornea material stiffness on measured intraocular pressure. J Biomech 41(8):1707–171310.1016/j.jbiomech.2008.03.004 ↗
12. Norman RE et al (2011) Finite element modeling of the human sclera: influence on optic nerve head biomechanics and connections with glaucoma. Exp Eye Res 93(1):4–1210.1016/j.exer.2010.09.014 ↗
13. Anderson K, El-Sheikh A, Newson T (2004) Application of structural analysis to the mechanical behaviour of the cornea. J R Soc Interface 1(1):3–1510.1098/rsif.2004.0002 ↗
14. Boyce BL et al (2008) Full-field deformation of bovine cornea under constrained inflation conditions. Biomaterials 29(28):3896–390410.1016/j.biomaterials.2008.06.011 ↗
15. Chu TC, Ranson WF, Sutton MA (1985) Applications of digital-image-correlation techniques to experimental mechanics. Exp Mech 25(3):232–24410.1007/BF02325092 ↗
16. Elsheikh A, Alhasso D, Rama P (2008) Biomechanical properties of human and porcine corneas. Exp Eye Res 86(5):783–79010.1016/j.exer.2008.02.006 ↗
17. Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol 53(1):34–4310.1111/j.1755-3768.1975.tb01135.x ↗
18. Siganos DS, Papastergiou GI, Moedas C (2004) Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 30(4):746–75110.1016/j.jcrs.2003.12.033 ↗
19. Whitacre MM, Stein RA, Hassanein K (1993) The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 115(5):592–59610.1016/S0002-9394(14)71455-2 ↗
20. Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31(1):156–16210.1016/j.jcrs.2004.10.044 ↗
21. Shah S et al (2007) Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Investig Ophthalmol Vis Sci 48(7):3026–303110.1167/iovs.04-0694 ↗
22. Hong J et al (2013) A new tonometer--the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci 54(1):659–66510.1167/iovs.12-10984 ↗
23. Ji C et al (2015) Dynamic curvature topography for evaluating the anterior corneal surface change with Corvis ST. BioMed Eng Online 14(1):5310.1186/s12938-015-0036-2 ↗
24. Koprowski R et al (2014) Selected parameters of the corneal deformation in the Corvis tonometer. BioMed Eng Online 13(1):5510.1186/1475-925X-13-55 ↗
25. Fercher AF (2010) Optical coherence tomography—development, principles, applications. Z Med Phys 20(4):251–27610.1016/j.zemedi.2009.11.002 ↗
26. Gambichler T, Jaedicke V, Terras S (2011) Optical coherence tomography in dermatology: technical and clinical aspects. Arch Dermatol Res 303(7):457–47310.1007/s00403-011-1152-x ↗
27. Kaluzny BJ et al (2006) Spectral optical coherence tomography: a novel technique for cornea imaging. Cornea 25(8):960–96510.1097/01.ico.0000224644.81719.59 ↗
28. Kiernan DF, Mieler WF, Hariprasad SM (2010) Spectral-domain optical coherence tomography: a comparison of modern high-resolution retinal imaging systems. Am J Ophthalmol 149(1):18–3110.1016/j.ajo.2009.08.037 ↗
29. Kennedy BF et al (2012) Strain estimation in phase-sensitive optical coherence elastography. Biomed Opt Express 3(8):1865–187910.1364/BOE.3.001865 ↗
30. Kirkpatrick SJ, Wang RK, Duncan DD (2006) OCT-based elastography for large and small deformations. Opt Express 14(24):11585–1159710.1364/OE.14.011585 ↗
31. Sun C, Standish B, Yang VXD (2011) Optical coherence elastography: current status and future applications. J Biomed Opt 16(4):04300110.1117/1.3560294 ↗
32. Wang RK, Kirkpatrick S, Hinds M (2007) Phase-sensitive optical coherence elastography for mapping tissue microstrains in real time. Appl Phys Lett 90(16):16410510.1063/1.2724920 ↗
33. Zaitsev VY et al (2014) Elastographic mapping in optical coherence tomography using an unconventional approach based on correlation stability. J Biomed Opt 19(2):2110710.1117/1.JBO.19.2.021107 ↗
34. Ford MR et al (2011) Method for optical coherence elastography of the cornea. J Biomed Opt 16(1):01600510.1117/1.3526701 ↗
35. Kennedy BF et al (2011) In vivo three-dimensional optical coherence elastography. Opt Express 19(7):6623–663410.1364/OE.19.006623 ↗
36. Li J, Wang S, Singh M, Aglyamov S, Emelianov S, Twa M, Larin KV 2014. Air-puff OCE for assessment of mouse cornea in vivo, Progress in Biomedical Optics and Imaging - Proceedings of SPIE.10.1117/12.2042258 ↗
37. Twa MD et al (2014) Spatial characterization of corneal biomechanical properties with optical coherence elastography after UV cross-linking. Biomed Opt Express 5(5):1419–142710.1364/BOE.5.001419 ↗
38. Wang S, Larin KV (2014) Noncontact depth-resolved micro-scale optical coherence elastography of the cornea. Biomed Opt Express 5(11):3807–382110.1364/BOE.5.003807 ↗
39. Manapuram RK et al (2012) In vivo estimation of elastic wave parameters using phase-stabilized swept source optical coherence elastography. J Biomed Opt 17(10):10050110.1117/1.JBO.17.10.100501 ↗
40. Nguyen TM, Song S, Shi L, Wang RK, O'Donnell M, Shen TT, Huang Z 2014. Shear wave elastography of ex vivo human corneas using phase-sensitive optical coherence tomography, IEEE International Ultrasonics Symposium, IUS, pp 217–22010.1109/ULTSYM.2014.0055 ↗
41. Nguyen TD, Boyce BL (2011) An inverse finite element method for determining the anisotropic properties of the cornea. Biomech Model Mechanobiol 10(3):323–33710.1007/s10237-010-0237-3 ↗
42. Pandolfi A, Holzapfel GA (2008) Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations. J Biomech Eng 130(6):06100610.1115/1.2982251 ↗
43. Pandolfi A, Manganiello F (2006) A model for the human cornea: constitutive formulation and numerical analysis. Biomech Model Mechanobiol 5(4):237–24610.1007/s10237-005-0014-x ↗
44. Avril S, Badel P, Duprey A (2010) Anisotropic and hyperelastic identification of in vitro human arteries from full-field optical measurements. J Biomech 43(15):2978–298510.1016/j.jbiomech.2010.07.004 ↗
45. Fu J, Pierron F, Ruiz PD (2013) Elastic stiffness characterization using three-dimensional full-field deformation obtained with optical coherence tomography and digital volume correlation. J Biomed Opt 18(12):12151210.1117/1.JBO.18.12.121512 ↗
46. Kim J-H et al (2012) Experimental characterization of rupture in human aortic aneurysms using a full-field measurement technique. Biomech Model Mechanobiol 11(6):841–85310.1007/s10237-011-0356-5 ↗
47. Pierron F, Grediac M (2012) The virtual fields method: extracting constitutive mechanical parameters from full-field deformation measurements. Springer, New York, pp 1–51710.1007/978-1-4614-1824-5 ↗
48. Moussawi A et al (2013) The constitutive compatibility method for identification of material parameters based on full-field measurements. Comput Methods Appl Mech Eng 265:1–1410.1016/j.cma.2013.06.003 ↗
49. Chakraborty S, Ruiz PD (2012) Measurement of all orthogonal components of displacement in the volume of scattering materials using wavelength scanning interferometry. J Opt Soc Am A Opt Image Sci Vis 29(9):1776–178510.1364/JOSAA.29.001776 ↗
50. Bay BK et al (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39(3):217–22610.1007/BF02323555 ↗
51. Brault R et al (2013) In-situ analysis of laminated composite materials by X-ray micro-computed tomography and digital volume correlation. Exp Mech 53(7):1143–115110.1007/s11340-013-9730-9 ↗
52. Gillard F et al (2014) The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression. J Mech Behav Biomed Mater 29:480–49910.1016/j.jmbbm.2013.09.014 ↗
53. Limodin N et al (2010) Influence of closure on the 3D propagation of fatigue cracks in a nodular cast iron investigated by X-ray tomography and 3D volume correlation. Acta Mater 58(8):2957–296710.1016/j.actamat.2010.01.024 ↗
54. Pierron F et al (2013) Comparison of the mechanical behaviour of standard and Auxetic foams by X-ray computed tomography and digital volume correlation. Strain 49(6):467–48210.1111/str.12053 ↗
55. Nahas A et al (2013) 3D static elastography at the micrometer scale using Full Field OCT. Biomed Opt Express 4(10):2138–214910.1364/BOE.4.002138 ↗
56. Ortiz S et al (2009) Optical coherence tomography for quantitative surface topography. Appl Opt 48(35):6708–671510.1364/AO.48.006708 ↗
57. Podoleanu A et al (2004) Correction of distortions in optical coherence tomography imaging of the eye. Phys Med Biol 49(7):1277–129410.1088/0031-9155/49/7/015 ↗
58. Van Der Jeught S et al (2013) Real-time correction of geometric distortion artefacts in large-volume optical coherence tomography. Meas Sci Technol 24(5):05700110.1088/0957-0233/24/5/057001 ↗
59. Patel S, Marshall J, Fitzke Iii FW (1995) Refractive index of the human corneal epithelium and stroma. J Refract Surg 11(2):100–10510.3928/1081-597X-19950301-09 ↗
60. Westphal V et al (2002) Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat’s principle. Opt Express 10(9):397–40410.1364/OE.10.000397 ↗
61. Hamilton KE, Pye DC (2008) Young’s modulus in normal corneas and the effect on applanation tonometry. Optom Vis Sci 85(6):445–45010.1097/OPX.0b013e3181783a70 ↗
62. MacRae S, Schwiegerling J, Snyder RW (1999) Customized and low spherical aberration corneal ablation design. J Refract Surg 15(2 Suppl):S246–S248
63. Komai Y, Ushiki T (1991) The three-dimensional organization of collagen fibrils in the human cornea and sclera. Invest Ophthalmol Vis Sci 32(8):2244–2258