journal article·2004-02

Experimental modal analysis of a synthetic composite femur

J. F. Dias Rodrigues, H. Lopes, F. Q. de Melo, J. A. Simões

Experimental Mechanics· Volume 44· Issue 1
Publisher page

Abstract

In this paper we describe the experimental characterization of the modal parameters of a synthetic composite femur model widely used in biomechanical research studies. The objective of the experimental procedure was to identify the natural frequencies and mode shapes of an unconstrained (free-free) femur. The experimental data were compared with the same obtained in an analog study performed with a fresh cadaveric femur bone. Other objective of the study was to investigate modal analysis as a technique to validate a finite element model of a composite femur with isotropic material properties.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hip disorders and treatments · Orthopaedic implants and arthroplasty · Cardiac Valve Diseases and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Pope, M.H., Wilder, D.G., Jorneus, L., Broman, H., Svensson, M., andAndersson, G.B.J., “The Response of the Seated Human to Sinusoidal Vibration and Impact,”Journal of Biomechanical Engineering,109,279–284 (1987).10.1115/1.3138681 ↗
2. Georgiou, A.P. and Cunningham, J.L., “The Clinical Diagnosis of Hip Prosthesis: Loosening Using a Vibrational Technique,” Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, 152 (2000).
3. Denayer, I., Jaeques, S.V.N., Burny, F., Puers, R., Borgwardt, A., and Van der Perre, G., “Measurement of Implant Stability and Osseintegration: Non-linearities and Resonance Frequencies,” Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, 151 (2000).
4. Klabunde, R., Roland, E., Taylor, W.R., Clift, S.E., and Rakotomanana, L., “Experimental Validation of an Orthotropic FE Model Using Modal Analysis,” Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin 454 (2000).
5. Beals, N., “Evaluation of a Composite Sawbones Femur Model,”Research Report ML-87-25, Richards Medical Company, Memphis, TN (1987).
6. Bianco, P.T., Bechtold, J.E., Kyle, R.F., and Gustilo, R.B., “Synthetic Composite Femurs for Use in Evaluation of Torsional Stability of Cementless Femoral Prosthesis,” Proceedings of the Biomechanics Symposium, P. A. Torzilli and M.H. Friedman, editors, ASME AMD, 297–300 (1989).
7. Cristofolini, L., Viceconti, M., Cappello, A., andToni, A., “Mechanical Validation of Whole Bone Composite Femur Models,”Journal of Biomechanics,29 (4),525–535 (1996).10.1016/0021-9290(95)00084-4 ↗
8. McKellop, H., Ebramzdeh, E., Niederer, P.G., andSarmiento, A., “Comparison of the Stability of Press-Fit Hip Prosthesis Femoral Stems Using a Synthetic Model Femur,”Journal of Orthopedic Research, 9, 297–305 (1991).10.1002/jor.1100090219 ↗
9. McNamara, B.P., Viceconti, M., Cristofolini, L., Toni, A., andTaylor, D., “Experimental and Numerical Pre-clinical Evaluation Relating to Total Hip Arthroplasty,”Proceedings of the 2nd International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, J. Middleton, editor, Gordon and Breach, the Netherlands, 1–10 (1996).
10. Otani, T., Whiteside, L.A., andWhite, S.E., “Strain Distribution in the Proximal Femur with Flexible Composite and Metallic Femoral Components Under Axial and Torsional Loads,”Journal of Biomedical Material Research,27,575 (1993).10.1002/jbm.820270504 ↗
11. Szivek, J.A., Weng, M., andKarpman, R., “Variability in the Torsional and Bending Response of a Commercially Available Composite Femur,”Journal of Applied Biomaterials,1,183–186 (1990).10.1002/jab.770010210 ↗
12. Szivek, J.A. andGealer, R.L., “Comparison of the Deformation Response of Synthetic and Cadaveric Femora During Simulated One-Legged Stance,”Journal of Applied Biomaterials,2,277–280 (1991).10.1002/jab.770020410 ↗
13. Uta, S., “Development of Synthetic Bone Models for the Evaluation of Fracture Fixation Devices,”Nippon Seikegeka Gakkai Zasshi,66 (11),1156–1164 (1992).
14. Viceconti, M., Casali, M., Massari, B., Cristofolini, L., Bassini, S., andToni, A., “The ‘Standardized Femur Program’. Proposal for a Reference Geometry to be Used for the Creation of Finite Element Models of the Femur,”Journal of Biomechanics,29,1241 (1996).10.1016/0021-9290(95)00164-6 ↗
15. Ewins, D.J., “Modal Testing—Theory, Practice and Application,” 2nd edition, Research Studies Press (2000).
16. LMS, LMS CADA-PC User Manual, Revision 1.2, LMS International (1993).