journal article·2006-04-04

Micrometer‐Scale Tensile Testing of Biological Attachment Devices

S. Orso, U. G. K. Wegst, C. Eberl, E. Arzt

Advanced Materials· Volume 18· Issue 7
Publisher page

Abstract

Using a focused ion beam system as an in situ laboratory for sample preparation, fixation, and testing at the micrometer scale, the mechanical properties of microscopic biological and technical samples can be measured in tension, bending, and compression. Samples such as individual hairs of the brush-like attachment systems of insects and geckos (see figure), natural and biomimetic spider silk, and carbon nanotubes can be measured with this method.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Adhesion, Friction, and Surface Interactions · Force Microscopy Techniques and Applications · Surface Modification and Superhydrophobicity

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. S. N. Gorb Attachment Devices of Insect Cuticle Kluwer Dordrecht The Netherlands2001.
2. 10.1038/3501507310.1038/35015073 ↗
3. 10.1073/pnas.19225279910.1073/pnas.192252799 ↗
4. 10.1098/rspa.2004.132610.1098/rspa.2004.1326 ↗
5. 10.1073/pnas.153470110010.1073/pnas.1534701100 ↗
6. 10.1016/j.actbio.2004.08.00410.1016/j.actbio.2004.08.004 ↗
7. 10.1126/science.287.5453.63710.1126/science.287.5453.637 ↗
8. 10.1023/A:102636521930710.1023/A:1026365219307 ↗
9. 10.1016/S0022-5096(02)00062-510.1016/S0022-5096(02)00062-5 ↗
10. 10.1063/1.177530910.1063/1.1775309 ↗
11. 10.1126/science.109899310.1126/science.1098993 ↗
12. 10.1109/84.91110310.1109/84.911103 ↗
13. Nascatec GmbH Ludwig‐Erhard‐Straße 10 34131 Kassel Germany.
14. Kleindiek Nanotechnik GmbH Aspenhaustraße 25 72770 Reutlingen Germany.
15. FEI Company 5350 NE Dawson Creek Drive Hillsboro OR 97124.
16. BIOPAC Systems Inc. (Model MP100A‐CE) 42 Aero Camino Goleta CA 93117.
17. W. Rasband ImageJ Version 1.32j (available fromhttp://rsb.info.nih.gov/ij/) National Institutes of Health Bethesda MD2004.
18. U. G. K. Wegst Natural Materials Selector created usingCES Constructor Granta Design Ltd. Rustat House 62 Clifton Road Cambridge CB1 7EG UK2004.
19. 10.1016/j.asd.2004.05.00610.1016/j.asd.2004.05.006 ↗
20. N. Barbakadse Ph.D. Thesis Universität Stuttgart2005.
21. 10.1023/B:JMSC.0000012925.92504.0810.1023/B:JMSC.0000012925.92504.08 ↗
22. 10.1016/j.jbiomech.2003.09.02810.1016/j.jbiomech.2003.09.028 ↗