Failures of cranes due to wind induced vibrations
Source abstract
Abstract
Abstract Self-excited vibrations with large amplitudes in natural wind may occur at slender structural elements with low damping. Because of the different designs (e. g. using solid sections today instead of cables for tension elements in the past) the susceptibility to wind induced oscillations has increased. Those wind induced vibrations of profiles with specific cross section geometry which are motion induced and therefore self-exciting are called “galloping vibrations”. Especially systems with elements that are highly tensile loaded and undamped, like hangers of bridges or tension bars of cranes, are sensitive to wind induced vibrations. Therefore more and more fatigue problems caused by galloping oscillations have occurred in the 1990s. This paper describes exemplary the collapses of two modern cranes of different design and manufacturers. During standstill periods, both cranes suffered from wind induced vibrations of the tension bars, which bear up the counterweights. The failure analysis process to identify and explain the fatigue fractures as well as the comparative experiments and simulation to verify that they were caused by wind induced galloping-vibrations is described. It is shown, which parameters led to galloping-vibrations of the tension bars and how their onset wind speed and the amplitudes can be estimated with more accuracy by a non-linear and non-stationary approach. Furthermore it is shown that such dynamic stresses caused fatigue failure of the tension bars for the counter weights and subsequently collapsing of the cranes. For loss prevention knowledge and results gained by these investigations should be put at disposal to engineers working on this field of design. In the meantime, a contribution to development of appropriate technical standards on structural steelwork was given by the research works on galloping. Although new standards were introduced, which consider wind induced vibrations, such failures still occur. (Reference to the paper “Fatigue crack in railway bridge hanger due to wind induced vibrations – failure analysis, measures and remaining service life estimation” in this same Special Issue “A tribute to A. Martens” 2014).
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Engineering and Vibration Analysis · Mechanical and Thermal Properties Analysis · Structural Engineering and Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Lüesse G, Ruscheweyh H, et al. Rain-wind induced vibrations at the bridge over the river Elbe near Dömitz (Regen-Wind-induzierte Schwingungserscheinungen an der Elbebrücke Dömitz) in German.- Stahlbau 1996;65(3): 105–14.
2. Scanlan · 1978
3. Petersen C. Wind induced vibrations and their prevention by dampers (Windinduzierte Schwingungen und ihre Verhütung durch Dämpfer) in German. – Der Stahlbau 1982;11: 336–341.
4. A study of the low-cycle fatigue failure of a galvanised steel lighting column10.1016/j.engfailanal.2009.02.012 ↗
5. Vortex-excited vibrations and galloping of slender elements10.1016/S0167-6105(97)00052-4 ↗
6. Failure analysis of the highway sign structure and the design improvement10.1016/j.engfailanal.2011.02.006 ↗
7. Göbel S. Crash of counterweights of a tower crane due to dynamic wind loads: causes and consequences. (“Absturz der Kontergewichte eines Turmdrehkranes infolge dynamischer Windbeanspruchung: Ursachen und Folgen”). in: VDI-Bericht zur 8. Jahrestagung “Werkstoff-Bauteil-Schaden”, Düsseldorf; 1996, in German.
8. Klinger C, Schrimmer P, et al. Failure analysis on the fracture of the counterweight jib tension rods of a tower crane. (“Schadensanalyse über das Versagen der Gegenauslegerabspannung eines Turmdrehkranes”). Expert report BAM-1.3/069, Federal Institute for Materials Research and Testing (BAM) 31.10.1995, unpublished results, (in German).
9. Ruscheweyh H. Assessment of the cause of the damage of the tension bars of the Mannesmann-Demag PC9600 crane regarding the fatigues fracture caused by wind induced vibrations, Report R444 Chair for steel construction, RWTH-Aachen, 02.12.1994, unpublished results.
10. Ruscheweyh H, Verwiebe C, Hortmanns M. Aerodynamic investigation of the failure of tension rods of counterweight jib. (“Aerodynamische Untersuchung des Schadensfalles an den Abspannstangen des Krangegenauslegers”) Report R579 Chair for steel construction, RWTH Aachen 25.07.1995, unpublished results, (in German).
11. System Identification for estimation of flutter derivatives
12. Klinger C, Hortmanns M, Ruscheweyh H, Wohler H. Crane failures due to wind induced vibrations. (“Kranschäden durch windinduzierte Schwingungen”) in German – Stahlbau 1996;65(10): 377–91.
13. DIN 15018, part 1, Cranes, Basics for steel structures. Calculation (“Krane, Grundsätze für Stahltragwerke – Berechnung”) (Nov. 1984) DIN 15018, part 2, Cranes, steel structures; Basics for design and realization (“Grundsätze für die bauliche Durchbildung und Ausführung”) (November 1984). in German.
14. Analysis of the catastrophic failure of a dockside crane jib10.1016/j.engfailanal.2013.02.026 ↗
15. Klinger C, Krüger M, et al. Estimation of structural damping of counterweight tension rods (“Ermittlung der Systemdämpfung der Gegenauslegerabspannungen”). Expert report BAM-V.3/22, Federal Institute for Materials Research and Testing (BAM), 06.05.1996, unpublished results, (in German).
16. Den Hartog · 1936
17. A new approach for determining the onset velocity of galloping instability taking into account the nonlinearity of the aerodynamic damping characteristic10.1016/S0167-6105(97)00164-5 ↗
18. Hortmanns M. On the identification and consideration of non-linear aeroelastic effects. (“ur Identifikation und Berücksichtigung nichtlinearer aeroelasti scher Effekte”). PhD Thesis; Chair for steel construction, RWTH-Aachen, Aachen: Shaker, 1997 (Schriftenreihe Stahlbau – RWTH-Aachen; Heft 34) (in German).
19. Ruscheweyh H, Hortmanns M. Wind tunnel testing for estimation of Galloping amplitudes of the tension rods o a counterweight jib. (“Windkanalversuch zur Ermittlung des Galloping-Amplitudenverlaufs für die Abspannstangen des Krangegenauslegers…”) Report R603 Chair for steel construction, RWTH Aachen 24.10.1995, unpublished results, (in German).
20. EN 1993-1-9: Eurocode 3: Design of steel structures. Part 1–1: General rules and rules for buildings; part 1–9 Fatigue, EN 1993-1-9:2005.
21. Ruscheweyh H, Hortmanns M. Measures for prevention of wind induced vibrations on tension rods of a crane counterweight jib. (“Maßnahmen zur Vermeidung windinduzierter Schwingungen an den Abspannstangen des Krangegenauslegers”)…, Report R616, Chair for steel construction, RWTH Aachen 06.12.1995, unpublished results, (in German).
22. Ruscheweyh H, Hortmanns M. Calculation of Galloping amplitudes time history for the damped tensions rods of a counterweight jib. (“Berechnung des Galloping amplituden-verlaufs für die gedämpften Abspannstangen des Krangegenauslegers…”), Report R640, Chair for steel construction, RWTH Aachen, 23.4.1996, unpublished results, (in German).
23. Numerical and experimental study of vibration mitigation for highway light poles10.1016/j.engstruct.2006.06.023 ↗
24. Eurocode 1: EN 1991-1-4 Basis of Design and Actions on Structures; Part 1. 4: Wind Actions 2005 with national amendment NA DIN EN 1991-1-4:2010-12.
25. Development of a method for calculating galloping amplitudes considering nonlinear aerodynamic coefficients measured with the forced oscillation method10.1016/S0167-6105(97)00159-1 ↗