Investigation of failure of steel steam generating evaporator tube involving delamination defects and corrosion
Source abstract
Abstract
Abstract A low carbon steel tube burst at a coal powered power station (Orot-Rabin station, Hadera-Israel). The tube was composed of material specified to ASTM A210M-02 Gr. A1. The bursting of the tube caused a steam/water mix to escape through a hole during initial unit activation after maintenance repairs. The tube is a diagonal ribbed steam-generating tube, mainly used as a physical support for a superheater coil assembly. During internal visual inspection using a borescope, it was seen that a whole layer of metal had partially detached from the area around the hole, causing the tube wall to thin considerably prior to failure. Moreover, it was seen that the same area had undergone corrosion at an advanced stage. Optical metallography revealed that the metal layer had detached from the tube's internal surface due to a wide and thick two-dimensional delamination defect present beneath the internal surface, and that a large amount of copper was present near the detached layer's edge. Scanning Electron microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) verified the existence of an abnormal concentration of copper and zinc at the same location. This led to the final conclusion that the hole in the tube had formed due to a combination of a wide delamination defect left over from production, and severe galvanic corrosion enabling the defect's exposure and delamination, eventually causing wall thinning and failure.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Non-Destructive Testing Techniques · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Erenburg · 2005
2. Metallurgical investigation of a failure in 316L stainless steel orthopedic implant10.1016/j.engfailanal.2004.05.004 ↗
3. Long-term changes in a heat exchanger steel
4. Microstructural changes during creep of a high chromium steel10.1007/BF02664676 ↗
5. Failure of a 17-4 PH stainless steel sailboat propeller shaft10.1016/S1350-6307(03)00041-4 ↗
6. Estimation of oxide scale growth and temperature increase of high (9–12%) chromium martensitic steels of superheater tubes10.1016/j.engfailanal.2013.03.014 ↗
7. Wrong heat treatment of martensitic steel welded tubes caused major cracking during assembly of resuperheaters in a fossil fuel power plant10.1016/S1350-6307(03)00039-6 ↗
8. Failure of a martensitic stainless steel pipe weld in a fossil fuel power plant10.1016/S1350-6307(01)00019-X ↗
9. Quantitative observations of precipitation in 2.25 Cr–1Mo steel exposed to different creep conditions in a power station10.1016/j.engfailanal.2008.09.009 ↗
10. Failure analysis and metallurgical transitions in SS 304L air pipe caused by local overheating10.1016/j.engfailanal.2015.10.014 ↗
11. French · 1993
12. Erosion corrosion of pump impeller of cyclic cooling water system10.1016/j.engfailanal.2005.07.012 ↗
13. Assessment of a gouge and dent defect in a pipeline by a combined criterion10.1016/j.engfailanal.2013.10.002 ↗
14. Failure of a twist drill10.1115/1.3443200 ↗
15. Becker · 2002 · 111
16. ASTM E 1476-04 · 2014
17. ASTM A 262-02a · 2006
18. ASTM A 210/A 210M-02 · 2012
19. Korb · 1989
20. Porter · 1992
21. Burke · 1965