Failure analysis of K-monel 500 (Ni–Cu–Al alloy) bolts
Source abstract
Abstract
Abstract A bolt manufacturer used several subcontractors to fabricate K-monel 500 bolts. The completed bolts failed mechanical testing, and the manufacturer ascribed the failure to the bar stock. Testing contracted by the supplier of the bar stock showed that it met specifications. Metallographic testing described here shows that the bolts failed because of excessive grain growth and subsequent softening during heat treatment performed on the bolts after they were formed. Alternative heat treatments are discussed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: High Temperature Alloys and Creep · Microstructure and Mechanical Properties of Steels · Metallurgy and Material Forming
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (9)
Show source-provided references
1. Dey · Materials Science Engineering · 1986 · 84 · 17710.1016/0025-5416(86)90236-3 ↗
2. Dey · Metallurgical Transactions · 1993 · 24A · 270910.1007/BF02659495 ↗
3. 1984
4. 1988
5. Federal Specification QQ-N-286E, Nickel–Copper–Aluminum Alloy, Wrought, 1985
6. Underwood · 1970
7. Fernsler EB. Metals Handbook. 2. American Society for Metals, Metals Park, OH, 1964. p. 297
8. Staley · J. Heat Transfer of Metals · 1987 · 3 · 923
9. Tillack DJ, Manning JM, Hensley JR. ASM handbook, vol. 4. 1991. p. 910