Sudden collapse of a 19th-century masonry structure during its renovation process
Source abstract
Abstract
Abstract The investigation and analysis conducted after a catastrophe of a 19th-century masonry structure are presented. During restoration work of a masonry building there was a sudden collapse of the structure, involving parts of a three-storey high outer supporting wall of the building together with the two floors resting on steel beams, as well as the wooden floor of the attic. The modernization works were carried out according to a detailed project documentation. Prior to the beginning of the destruction process there had been no demolition activities going on. Hence, it was essential to determine the actual causes of the collapse as well as to give details concerning the time when the catastrophe occurred. Detailed inventory measurements and non-destructive “in situ” tests, followed by laboratory tests, are described. The tests involved both ceramic materials and lime mortar, as well as steel and wooden parts of the structural elements. Numerical computations of the approximate bearing capacity of the modernized system prior to the catastrophe were performed in a comprehensive way to build a model using the Finite Element Method (FEM). The model employed mostly standard four-node plate-and-disc components of the flat shell type. The computations concerned the static field. Also the effects related to the stability of the structure in terms of large displacements were analyzed. For the computations, an original software was used. As a result of the conducted studies and analyses, it was established and confirmed quantitatively that the main causes of the building disaster were faults made when preparing openings for shop windows in the non-homogeneous structure of the wall. However, the most important issue was flaws of the mortar binding the ceramic elements of the wall. The paper concludes that in the course of wide-ranging restoration of historical facilities, it should be entirely prohibited to treat the building's elements as structural ones. In cases of “limited structural reliability” with respect to the historical facilities, loads should be taken by an independent structure. The modernization works must be carried out under on-going constant supervision of an experienced designer and project manager. The paper ends by presenting a concept of rebuilding of the damaged parts of the facility.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Civil and Structural Engineering Research · Structural Analysis of Composite Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Evaluation of the mechanical properties of reinforcing steel bars from collapsed building sites10.1007/s11668-013-9739-5 ↗
2. Investigation of the cyclic inelastic capacity of steel beams through the use of the plastic collapse mechanism10.1007/s10518-014-9665-2 ↗
3. Structural behavior of the old masonry bridge in the Gulf of Castellammare10.1016/j.engfailanal.2016.02.007 ↗
4. Experimental and analytical investigation on the frictional contact behavior of 3D masonry block assemblages10.1016/j.conbuildmat.2014.12.100 ↗
5. Influence of pre-soaked recycled fine aggregate on the properties of masonry mortar10.1016/j.conbuildmat.2014.07.098 ↗
6. Assessing the durability of mortars tiles – a contribution for a prediction model10.1016/j.engfailanal.2014.04.027 ↗
7. Detection of façade plaster detachments using infrared thermography – a nondestructive technique10.1016/j.conbuildmat.2014.07.094 ↗
8. Experimental investigation on bricks from historical Venetian buildings subjected to moisture and salt crystallization10.1016/j.engfailanal.2014.06.019 ↗
9. Hybrid simulation framework for immediate facility restoration planning after a catastrophic disaster10.1061/(ASCE)CO.1943-7862.0001146 ↗
10. Static penetration test for historical masonry mortar10.1016/j.conbuildmat.2016.07.097 ↗
11. Experimental research of masonry compressive strength in the Auschwitz II - Birkenau former death camp buildings10.1016/j.engfailanal.2016.06.007 ↗
12. Structural behaviour of masonry panels strengthened with an innovative hemp fibre composite grid10.1016/j.conbuildmat.2015.09.051 ↗
13. Static analysis of building structures with regard to their implementation in stages10.1016/j.engstruct.2015.08.002 ↗
14. Comparative pushover and limit analyses on seven masonry churches damaged by the 2012 Emilia-Romagna (Italy) seismic events: possibilities of non-linear finite elements compared with pre-assigned failure mechanisms10.1016/j.engfailanal.2014.09.016 ↗
15. Pre-diagnostic prompt investigation and static monitoring of a historic bell-tower10.1016/j.conbuildmat.2016.04.016 ↗
16. Numerical analysis of structural damage in the church of the Poblet Monastery10.1016/j.engfailanal.2014.10.015 ↗
17. Integrated risk-assessment framework for municipal infrastructure
18. Influence of substrate and sand characteristics on Roman cement mortar performance10.1016/j.conbuildmat.2015.05.077 ↗
19. The change in selected properties of ceramic materials obtained from ceramic brick treated by the sulphate and chloride ions10.1016/j.conbuildmat.2014.05.066 ↗
20. Direction for generating interest for design for construction worker safety—a Delphi study
21. PN-B-03002 · 2007