journal article·2022-02Open access

Auxetics‐Inspired Tunable Metamaterials for Magnetic Resonance Imaging

Ke Wu, Xiaoguang Zhao, Thomas G. Bifano, Stephan W. Anderson, Xin Zhang

Advanced Materials· Volume 34· Issue 6

Abstract

Abstract Auxetics refers to structures or materials with a negative Poisson's ratio, thereby capable of exhibiting counterintuitive behaviors. Herein, auxetic structures are exploited to design mechanically tunable metamaterials in both planar and hemispherical configurations operating at megahertz (MHz) frequencies, optimized for their application to magnetic resonance imaging (MRI). Specially, the reported tunable metamaterials are composed of arrays of interjointed unit cells featuring metallic helices, enabling auxetic patterns with a negative Poisson's ratio. The deployable deformation of the metamaterials yields an added degree of freedom with respect to frequency tunability through the resultant modification of the electromagnetic interactions between unit cells. The metamaterials are fabricated using 3D printing technology and an ≈20 MHz frequency shift of the resonance mode is enabled during deformation. Experimental validation is performed in a clinical (3.0 T) MRI system, demonstrating that the metamaterials enable a marked boost in radiofrequency field strength under resonance‐matched conditions, ultimately yielding a dramatic increase in the signal‐to‐noise ratio (≈4.5×) of MRI. The tunable metamaterials presented herein offer a novel pathway toward the practical utilization of metamaterials in MRI, as well as a range of other emerging applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cellular and Composite Structures · Metamaterials and Metasurfaces Applications · Advanced Materials and Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering Boston University Boston MA 02215 USA

Photonics Center Boston University Boston MA 02215 USA

Department of Radiology Boston University Medical Campus Boston MA 02118 USA

Funding

National Institute of Biomedical Imaging and Bioengineering

References (32)

Show source-provided references
1. 10.1038/nmat214110.1038/nmat2141 ↗
2. 10.1126/science.113102510.1126/science.1131025 ↗
3. 10.1103/PhysRevLett.100.20740210.1103/PhysRevLett.100.207402 ↗
4. 10.1364/PRJ.4.000A1610.1364/PRJ.4.000A16 ↗
5. 10.1126/science.113362810.1126/science.1133628 ↗
6. 10.1038/nphoton.2007.2810.1038/nphoton.2007.28 ↗
7. 10.1109/JPROC.2012.218763110.1109/JPROC.2012.2187631 ↗
8. 10.1002/adma.20150427010.1002/adma.201504270 ↗
9. 10.1038/s42005-019-0135-710.1038/s42005-019-0135-7 ↗
10. 10.1103/PhysRevLett.109.08390210.1103/PhysRevLett.109.083902 ↗
11. 10.1038/ncomms759010.1038/ncomms7590 ↗
12. 10.1038/nature0534310.1038/nature05343 ↗
13. 10.1002/adma.20120041910.1002/adma.201200419 ↗
14. 10.1364/OPTICA.5.00030310.1364/OPTICA.5.000303 ↗
15. 10.1103/PhysRevB.82.15512810.1103/PhysRevB.82.155128 ↗
16. 10.1063/1.352516910.1063/1.3525169 ↗
17. 10.1007/978-981-287-275-310.1007/978-981-287-275-3 ↗
18. 10.1039/C6RA27333E10.1039/C6RA27333E ↗
19. 10.1088/1361-665X/aaa61c10.1088/1361-665X/aaa61c ↗
20. 10.1023/B:JMSC.0000026928.93231.e010.1023/B:JMSC.0000026928.93231.e0 ↗
21. 10.1177/004051751244905110.1177/0040517512449051 ↗
22. 10.1021/ie990572w10.1021/ie990572w ↗
23. 10.1038/srep0839510.1038/srep08395 ↗
24. Smith W. A. · Proc. IEEE Ultrasonics Symp. · 1991 · 1 · 661
25. 10.1088/0964-1726/22/8/08401210.1088/0964-1726/22/8/084012 ↗
26. 10.1023/A:100678122400210.1023/A:1006781224002 ↗
27. Haus H. A. · 1984
28. 10.1556/Pollack.6.2011.2.810.1556/Pollack.6.2011.2.8 ↗
29. C.HobermanUS 4942700 1990.
30. C.HobermanUS 5024031 1991.
31. 10.1007/s11465-019-0567-510.1007/s11465-019-0567-5 ↗
32. 10.1118/1.361873010.1118/1.3618730 ↗