Tailoring Cell Adhesion Using Surface‐Grafted Polymer Gradient Assemblies
Source abstract
Abstract
Surface-grafted polymer assemblies with a gradient in molecular weight (MW) and/or grafting density (σ) are used to tune protein adsorption, which consequently governs cell adhesion. Increasing the surface coverage of the polymer by increasing the MW and/or σ results in a decrease in the amount of protein adsorbed, which causes a decrease in the number of cells adhered and a change in cell morphology.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Polymer Surface Interaction Studies · Nanofabrication and Lithography Techniques · Cellular Mechanics and Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. 10.1016/S0039-6028(01)01587-410.1016/S0039-6028(01)01587-4 ↗
2. Biomaterials Science–An Introduction to Materials in Medicine (Eds: B. D. Ratner A. S. Hoffman F. J. Schoen J. E. Lemons) Elsevier San Diego CA2004.
3. Principles of Tissue Engineering (Eds: R. P. Lanza R. S. Langer W. L. Chick) Academic Press Austin TX1997.
4. 10.1146/annurev.cb.03.110187.00114310.1146/annurev.cb.03.110187.001143 ↗
5. 10.1016/0092-8674(92)90115-S10.1016/0092-8674(92)90115-S ↗
6. 10.1042/bj339048110.1042/bj3390481 ↗
7. 10.1016/0092-8674(86)90259-X10.1016/0092-8674(86)90259-X ↗
8. Rusoslahti E. · Nature · 1984 · 309 · 3010.1038/309030a0 ↗
9. 10.1242/jcs.113.10.167710.1242/jcs.113.10.1677 ↗
10. 10.1016/0079-6700(95)00011-410.1016/0079-6700(95)00011-4 ↗
11. 10.1021/ja00076a03210.1021/ja00076a032 ↗
12. 10.1016/j.biomaterials.2003.09.06910.1016/j.biomaterials.2003.09.069 ↗
13. 10.1021/la010384m10.1021/la010384m ↗
14. 10.1146/annurev.bb.25.060196.00041510.1146/annurev.bb.25.060196.000415 ↗
15. 10.1021/la048358m10.1021/la048358m ↗
16. 10.1163/156856299X0072010.1163/156856299X00720 ↗
17. 10.1146/annurev.ms.26.080196.00205310.1146/annurev.ms.26.080196.002053 ↗
18. 10.1021/ma971016l10.1021/ma971016l ↗
19. 10.1016/j.susc.2004.06.18210.1016/j.susc.2004.06.182 ↗
20. Halperin A. · C. R. Acad. Sci. Paris · 2000 · 4 · 1171
21. 10.1016/S0001-8686(02)00061-110.1016/S0001-8686(02)00061-1 ↗
22. 10.1021/la970678110.1021/la9706781 ↗
23. 10.1163/15685620074386910.1163/156856200743869 ↗
24. 10.1038/2061256a010.1038/2061256a0 ↗
25. 10.1209/0295-5075/24/3/00510.1209/0295-5075/24/3/005 ↗
26. 10.1021/la981356f10.1021/la981356f ↗
27. 10.1016/0021-9797(91)90043-810.1016/0021-9797(91)90043-8 ↗
28. 10.1016/S0927-7765(02)00160-110.1016/S0927-7765(02)00160-1 ↗
29. 10.1016/S0006-3495(97)78698-310.1016/S0006-3495(97)78698-3 ↗
30. 10.1073/pnas.15023619710.1073/pnas.150236197 ↗
31. 10.1021/ma025937u10.1021/ma025937u ↗
32. 10.1021/ma025718910.1021/ma0257189 ↗
33. 10.1002/marc.20030016310.1002/marc.200300163 ↗
34. Bohnert J. L. · Investig. Opth. Vis. Sci. · 1988 · 29 · 362
35. 10.1021/la981345m10.1021/la981345m ↗
36. Since the polymerization initiator is distributed homogeneously on the substrate the grafting density of polymerized PHEMA chains can be presumed to be roughly constant. Accordingly a gradient in measured dry thickness of PHEMA is attributed primarily to a gradient in the MW of end‐grafted PHEMA. For details see reference [31].
37. 10.1016/S0074-7696(08)62241-X10.1016/S0074-7696(08)62241-X ↗
38. 10.1146/annurev.cb.04.110188.00241510.1146/annurev.cb.04.110188.002415 ↗
39. 10.1006/jcis.1994.101810.1006/jcis.1994.1018 ↗
40. 10.1002/jbm.82027081610.1002/jbm.820270816 ↗
41. 10.1002/(SICI)1521-4095(199808)10:12<901::AID-ADMA901>3.0.CO;2-B10.1002/(SICI)1521-4095(199808)10:12<901::AID-ADMA901>3.0.CO;2-B ↗
42. Bhat R. R. · Mat. Res. Soc. Symp. Proc. · 2004 · 804 · JJ.5.8.1
43. All Staining guidelines for AlexaFluor 594 Phalloidin and DAPI are included in Molecular Probes. Inc. Product Information Guides catalog numbers A12381 and D1306 respectively.