journal article·2009Open access

Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants

Takuma TSUGE, Yoshiyuki HAGIWARA

Dental Materials Journal· Volume 28· Issue 4

Abstract

To date, there is no evidence that internal anti-rotation configurations are better than external ones. The purpose of this study was to evaluate the effect of eccentric cyclic loading on abutment screw loosening in internal and external hexagon implants with either of these two screw materials, titanium (Ti) alloy versus gold alloy. The reverse torque value of the abutment screw was measured before (initial preload) and after loading (post-loading). The prepared assemblies were divided into four groups (A to D). Groups A and B used internal hex implants with gold alloy and Ti alloy abutment screws respectively. Groups C and D used external hex implants with gold alloy and Ti alloy abutment screws respectively. In all the groups, post-loading preload was significantly (p<0.05) higher than initial preload. Further, two-way ANOVA indicated that the implant-abutment connection did not have an effect, but the abutment screw material did. In particular, Ti abutment screws were less likely to come loose.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Surgery and Rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Nihon University Graduate School of Dentistry

Department of Fixed Prosthodontics, Nihon University School of Dentistry

Implant Dentistry, Nihon University School of Dentistry Dental Hospital

References (41)

Show source-provided references
1. 1) Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998; 79: 74-78.10.1016/S0022-3913(98)70197-0 ↗
2. 2) Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990; 64: 185-194.10.1016/0022-3913(90)90177-E ↗
3. 3) Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003; 90: 121-132.10.1016/S0022-3913(03)00212-9 ↗
4. 4) Johansson LA, Ekfeldt A. Implant-supported fixed partial prostheses: a retrospective study. Int J Prosthodont 2003;16: 172-176.
5. 5) Byrne D, Jacobs S, O'Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont 2006; 15: 164-171.10.1111/j.1532-849X.2006.00096.x ↗
6. 6) Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997; 77: 28-3510.1016/S0022-3913(97)70203-8 ↗
7. 7) Shigley JE. Mechanical engineering design, 3rd ed, McGraw-Hill, New York, 1977, pp.240-245.
8. 8) Rangert B, Jemt T, Jorneus L. Forces and moment on Brånemark implants. Int J Oral Maxillofac Implants 1989; 4: 241-247.
9. 9) Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992; 7: 353-359.
10. 10) Bickford JH. An introduction to the design and behavior of bolted joints, Marcel Dekker, New York, 1995, pp.515-564.
11. 11) McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin North Am 1998; 2: 71-89.10.1016/S0011-8532(22)00606-1 ↗
12. 12) Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001; 86: 24-32.10.1067/mpr.2001.116230 ↗
13. 13) Tan KB, Nicholls JI. Implant-abutment screw joint preload of 7 hex-top abutment systems. Int J Oral Maxillofac Implants 2001; 16: 367-377.
14. 14) Ekfeldt A, Carlsson GE, Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implant 1994; 9: 179-183.
15. 15) Haas R, Mensdorff-Pouilly N, Mailath G, Watzek G. Brånemark single tooth implants: a preliminary report of 76 implants. J Prosthet Dent 1995; 73: 274-279.10.1016/S0022-3913(05)80205-7 ↗
16. 16) Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995; 10: 326-334.
17. 17) Rangert BR, Sullivan RM, Jemt TM. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants 1997; 12: 360-370.
18. 18) Shigley JE, Mischke CR. Standard handbook of machine design, 1st ed, McGraw-Hill, New York, 1986, pp.23-26.
19. 19) English CE. Biomechanical concerns with fixed partial dentures involving implants. Implant Dent 1993; 2: 221-242.10.1097/00008505-199312000-00002 ↗
20. 20) Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995; 10: 295-302.
21. 21) Parein AM, Eckert SE, Wollan PC, Keller EE. Implant reconstruction in the posterior mandible: a long-term retrospective study. J Prosthet Dent 1997; 78: 34-42.10.1016/S0022-3913(97)70085-4 ↗
22. 22) Weinberg LA. Reduction of implant loading with therapeutic biomechanics. Implant Dent 1998; 7: 277-285.10.1097/00008505-199807040-00005 ↗
23. 23) Binon PP, Sutter F, Beaty K, Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994; 9: 48-63.
24. 24) Laney WR, Tolman DE. Tissue integration in oral, orthopedic, and maxillofacial reconstruction, 1st ed, Quintessence, Chicago, 1993, pp.218-226.
25. 25) Binon PP. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants 2000; 15: 76-94.
26. 26) Salinas TJ. Anti-rotational features for osseointegrated implants. Pract Proced Aesthet Dent 2001; 13: 352.
27. 27) Salinas TJ. A change of philosophy in abutment connections. Pract Proced Aesthet Dent 2002; 14: 471.
28. 28) Lee J, Kim YS, Kim CW, Han JS. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device. J Prosthet Dent 2002; 88: 402-408.10.1067/mpr.2002.128099 ↗
29. 29) Alkan I, Sertgöz A, Ekici B. Influence of occlusal forces on stress distribution in preloaded dental implant screws. J Prosthet Dent 2004; 91: 319-325.10.1016/j.prosdent.2004.01.016 ↗
30. 30) Khraisat A, Abu-Hammad O, Dar-Odeh N, Al-Kayed AM. Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading. Clin Implant Dent Relat Res 2004; 6: 157-164.10.1111/j.1708-8208.2004.tb00223.x ↗
31. 31) Khraisat A, Hashimoto A, Nomura S, Miyakawa O. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. J Prosthet Dent 2004; 91: 326-334.10.1016/j.prosdent.2004.01.001 ↗
32. 32) Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002; 28: 67-73.10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2 ↗
33. 33) Breeding LC, Dixon DL, Nelson EW, Tietge JD. Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont 1993; 6: 435-439.
34. 34) Standlee JP, Caputo AA. Accuracy of an electric torque-limiting device for implants. Int J Oral Maxillofac Implants 1999; 14: 278-281.
35. 35) Dixon DL, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent 1995; 74: 270-278.10.1016/S0022-3913(05)80134-9 ↗
36. 36) Craig RG. Restorative dental materials, 9th ed, Mosby, St Louis, 1993, pp.75-77.
37. 37) Mohl ND, Zarb GA, Carlsson GE, Rugh JD. A textbook of occlusion, 1988, Quintessence, Chicago, 1988, pp.143-152.
38. 38) International Organization for Standardization. ISO 14801:2003, Dentistry — Fatigue test for endosseous dental implants, Geneva, pp.1-9.
39. 39) Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995; 10: 326-334.
40. 40) Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000; 84: 194-199.10.1067/mpr.2000.108069 ↗
41. 41) Al Jabbari YS, Fournelle R, Ziebert G, Toth J, Iacopino AM. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 1: Characterization of adhesive wear and structure of retaining screws. J Prosthodont 2008; 17: 168-180.10.1111/j.1532-849X.2007.00265.x ↗