Surface analysis of commercially pure titanium implant retrieved from rat bone. part 1: Initial biological response of sandblasted surface
Source abstract
Abstract
To gain insight on the early biological response to commercial pure titanium (cpTi), the surface properties of cpTi implants retrieved from rat bone were examined by X-ray photoelectron spectroscopy (XPS). To this end, semi-cylindrical bullets, 1.1 mm in diameter and 3.5 mm in length, were implanted into the femurs of Wistar rats and then retrieved after either 3 hours or 7 days. Regardless of implantation interval, elements of Ti, O, C, and N were observed on the retrieved implants and that the thickness of the adsorbed film (mainly protein) was estimated to be about 2.5 nm. Small amounts of both Ca and P were also detected, whereby the Ca/P atomic ratios after 3 hours and 7 days were very small compared to that of hydroxyapatite. Furthermore, no correlation was found between the Ca and P distributions in the element maps. In conclusion, no calcium phosphate compounds were formed on the implant in vivo after 7 days.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. 1) Buddy DR, Allan SH, Frederick JS, Jack EL. Biomaterials Science. Academic Press, San Diego, 1996, pp.308-319.
2. 10.1016/S0167-5729(00)00011-X10.1016/S0167-5729(00)00011-X ↗
3. 10.1016/0142-9612(91)90028-910.1016/0142-9612(91)90028-9 ↗
4. 4) Frauchiger L, Taborelli M, Aronsson BO, Descouts P. Ion adsorption on titanium surfaces exposed to a physiological solution. Applied Surface Science 1999; 143: 67-77.10.1016/S0169-4332(98)00932-5 ↗
5. 10.1002/1097-4636(200105)55:2<185::AID-JBM1005>3.0.CO;2-P10.1002/1097-4636(200105)55:2<185::AID-JBM1005>3.0.CO;2-P ↗
6. 10.1002/(SICI)1097-4636(199704)35:1<39::AID-JBM5>3.0.CO;2-N10.1002/(SICI)1097-4636(199704)35:1<39::AID-JBM5>3.0.CO;2-N ↗
7. 10.1002/(SICI)1097-4636(19980905)41:3<341::AID-JBM1>3.3.CO;2-P10.1002/(SICI)1097-4636(19980905)41:3<341::AID-JBM1>3.3.CO;2-P ↗
8. 10.1016/0142-9612(91)90057-H10.1016/0142-9612(91)90057-H ↗
9. 10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B ↗
10. 10.1002/(SICI)1097-4636(20000305)49:3<345::AID-JBM7>3.0.CO;2-R10.1002/(SICI)1097-4636(20000305)49:3<345::AID-JBM7>3.0.CO;2-R ↗
11. 11) Murakami K, Ukai H. Surface and interface of artificial biomaterials. The interface structure between titanium and living cell MC3T3-E1. Surface Science 1999; 20: 640-649.
12. 12) Nanci A, McCarthy GF, Zalzal S, Clokie CML, Warshawsky H, McKee MD. Tissue response to titanium implants in the rat tibia: ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface. Cells and Materials 1994; 4: 1-30.
13. 10.1046/j.0905-7161.2003.00960.x10.1046/j.0905-7161.2003.00960.x ↗
14. 14) Fujii N, Kusakari H, Maeda T. A histological study on tissue responses to titanium implantation in rat maxilla: the process of epithelial regeneration and bone reaction. J Periodontol 1998; 69: 485-495.10.1902/jop.1998.69.4.485 ↗
15. 10.1002/sia.74021030210.1002/sia.740210302 ↗
16. 16) Chastain J, King Jr RC. Handbook of X-ray photoelectron spectroscopy, Physical Electronics Inc., Minnesota, USA, 1995, p.253.
17. 17) Lüth H. Solid surfaces, interfaces and thin films, 4th edn, Springer, Berlin, Germany, 2001, pp.69-70.
18. 10.1021/ac052243l10.1021/ac052243l ↗
19. 19) Alberts B, Johnson A, Lewis J, Raff M, Roberts K, Walter P. Molecular biology of the cell, 4th edn, Garland Science, New York, USA, 2002, p.149.
20. 10.1006/abio.1999.414210.1006/abio.1999.4142 ↗
21. 21) Barbucci R. Integrated biomaterials science, Kluwer Academic, New York, USA, 2002, pp.669-689.10.1007/b112196 ↗
22. WATANABE K · 2004 · 15 · 262
23. 23) Vickerman JC. Surface analysis—The principal techniques, John Wiley & Sons, New York, USA, 1998, pp.125-129.