Evaluation of Skin Irritation and Sensitization of Two Diol Solutions used as Experimental Dentin Primers in Humans and Guinea Pigs
Source abstract
Abstract
The purpose of the present study was to evaluate the safety of ethylene glyco (EG) and 1,6-hexanediol (HD) solutions as experimental dentin primers when subjected to the guinea pig maximization test (GPMT), primary irritation test, cumulative skin irritation test and human patch test. No primary and cumulative skin irritation resulting from the use of 62.5% EG or 45% HD solutions was observed. In the case of GPMT, the animals sensitized with 2-hydroxyethyl methacrylate (2-HEMA) responded to 100% HD. 62.5% EG and 45% HD as dentin primers were safer than 2-HEMA such as a methacrylic primer.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Animal testing and alternatives · Contact Dermatitis and Allergies · Advancements in Transdermal Drug Delivery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.