The visibility of secondary caries under bonding agents with two different imaging modalities
Source abstract
Abstract
This study investigated the visibility of secondary caries lesions associated with two different adhesive systems of composite restorations (Optibond Solo Plus and Clearfil SE Bond) using a conventional dental x-ray film (Kodak D Speed) and a digital system (Digora) based on storage phosphor-plate technology for detection of secondary caries. For imaging techniques and adhesive systems, false positive scores were high. Intraobserver agreements ranged between 0.432 and 0.778, while interobserver agreements for the readings ranged 0.321-0.731 and 0.411-0.701, respectively. No statistical difference was found between the Az (area under curve) values obtained from PSP (photostimulable storage phosphor) and film images with the exception of the second observer's first reading for total etch adhesive system (Optibond Solo Plus) (p=0.0258). Furthermore, no statistical difference was found between both the bonding systems assessed (p>0.05). Adhesive materials should also have enough radiopacity to facilitate diagnosis of secondary caries.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Radiography and Imaging · Dental materials and restorations · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. 1) Podshadley AG, Gullett CE. Is radiographic examination a reliable method of detecting caries under old restorations? J Am Dent Assoc 1979; 99: 603-634.10.14219/jada.archive.1979.0349 ↗
2. 2) Boksman L, Jordan RE, Suzuki M, Charles DH. A visible light-cured posterior composite resin: results of a 3-year clinical evaluation. J Am Dent Assoc 1986; 112: 627-631.10.14219/jada.archive.1986.0082 ↗
3. 3) Leinfelder KF. Current developments in posterior composite resins. Adv Dent Res 1988; 2: 115-121.10.1177/08959374880020010201 ↗
4. 4) Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA. Radiopacity of restorations and detection of secondary caries. Dent Mater 1991; 7: 114-117.10.1016/0109-5641(91)90056-5 ↗
5. 5) Goshima T, Goshima Y. Optimum radiopacity of composite inlay materials and cements. Oral Surg Oral Med Oral Pathol 1991; 72: 257-260.10.1016/0030-4220(91)90173-A ↗
6. 6) Sabbagh J, Vreven J, Leloup G. Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora). Oper Dent 2004; 29: 677-684.
7. 7) Nair MK, Ludlow JB, May KN, Nair UP, Johnson MP, Close JM. Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay. Oper Dent 2001; 26: 223-230.
8. 8) Pontual AA, de Melo DP, de Almeida SM, Bóscolo FN, Haiter Neto F. Comparison of digital systems and conventional dental film for the detection of approximal enamel caries. Dentomaxillofac Radiol 2010; 39: 431-436.10.1259/dmfr/94985823 ↗
9. 9) Akarslan ZZ, Akdevelioğlu M, Güngör K, Erten H. A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth. Dentomaxillofac Radiol 2008; 37: 458-463.10.1259/dmfr/84698143 ↗
10. 10) Salzedas LMP, Louzada MJQ, de Oliveira Filho AB. Radiopacity of restorative materials using digital images. J Appl Oral Sci 2006; 14: 147-152.10.1590/S1678-77572006000200015 ↗
11. 11) Van der Stelt PF. Principles of digital imaging. Dent Clin North Am 2000; 44: 237-248.10.1016/S0011-8532(22)01300-3 ↗
12. 12) Pamir T, Kaya AD, Baksi BG, Sen BH, Boyacioglu H. The influence of bonding agents on the decision to replace composite restorations. Oper Dent 2010; 35: 572-578.10.2341/10-097-L ↗
13. 13) Dentistry-Polymer based fillings, restorative and luting materials, ISO 4049. 3rd ed; Geneva: International Organization for Standardization; 2000.
14. 14) Kidd EA, Beighton D. Prediction of secondary caries around tooth-colored restorations: a clinical and microbiological study. J Dent Res 1996; 75: 1942-1946.10.1177/00220345960750120501 ↗
15. 15) Goshima T. The radiopacity of composite restorative materials. Dentomaxillofac Radiol 1986; 15: 37-40.10.1259/dmfr.1986.0005 ↗
16. 16) Hotta M, Yamamoto K. Comparative radiopacity of bonding agents. J Adhes Dent 2009; 11: 207-212.
17. 17) de Abreu MJ, Tavares D, Vierira DF. Radiopacity of restorative materials. Oper Dent 1997; 2: 3-16.
18. 18) Shey Z, Oppenheim M. A clinical evaluation of a radiopaque material in the restoration of anterior and posterior teeth. J Am Dent Assoc 1979; 98: 569-571.10.14219/jada.archive.1979.0093 ↗
19. 19) Senel B, Kamburoglu K, Uçok O, Yüksel SP, Ozen T, Avsever H.Diagnostic accuracy of different imaging modalities in detection of proximal caries. Dentomaxillofac Radiol 2010; 39: 501-511.10.1259/dmfr/28628723 ↗