journal article·2007-05

Qualitative analysis of adhesive interface nanoleakage using FE-SEM/EDS

Yang Yuan, Yasushi Shimada, Shizuko Ichinose, Junji Tagami

Dental Materials· Volume 23· Issue 5
Publisher page

Abstract

Objectives The purpose of this study was to evaluate the quality of short term sealing of current adhesives. Methods Five adhesive systems were used and evaluated in this study; two kinds of two-step adhesives (Single Bond and Clearfil SE Bond) and three one-step adhesives (Clearfil S3 Bond, G Bond and One-Up Bond F-plus). Flat occlusal superficial dentin surfaces from extracted human third molars were finished with wet 600-grit silicon-carbide paper and bonded with one of the adhesives. After 24h storage at 37 degrees C in water, the bonded assemblies were sectioned into approximately 1mm thick slabs. Two central slabs from each tooth were chosen and immersed into 50% (w/v) solution of silver ammoniacal nitrate for 18 h and exposed to photodeveloping solution for 6h. The specimens were then slightly polished, argon ion-etched. In order to examine the nanoleakage within the resin/dentin interface, penetration of silver was observed in a field emission (FE)-SEM using yttrium-aluminium-garnet (YAG) backscattered electron mode. EDS analysis was also carried out in parallel to identify the existence of metallic silver particles. Results The penetration pattern of silver depended on the adhesive used, indicating different nanoleakage in different adhesive systems. Single Bond, One-Up Bond F-plus and G Bond showed clear silver uptake in both the adhesive and hybrid layer. Clearfil SE Bond showed less silver penetration and slight silver peak on the elemental energy spectroscopy of EDS. Clearfil S3 Bond did not display clear silver penetration under 2000x magnification by FE-SEM, and no existence of metallic silver of the Clearfil S3 Bond group by EDS, could be detected. Significance The nanoleakage, as well as its location depends on the adhesives. Different nanoleakage expressions were revealed between two-step and one-step adhesives and also among one-step adhesives themselves.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. The clinical performance of adhesives10.1016/S0300-5712(96)00070-X ↗
2. Dentine permeability and dentine adhesion10.1016/S0300-5712(96)00057-7 ↗
3. Comparative SEM and TEM observations of nanoleakage within the hybrid layer
4. Nanoleakage: leakage within the hybrid layer
5. Nanoleakage patterns of dentin bonding system10.1016/S0109-5641(99)00085-8 ↗
6. Nanoleakage at the composite–dentin interface: a review
7. Two modes of nanoleakage expression in single-step adhesives10.1177/154405910208100708 ↗
8. Buonocore memorial lecture—adhesion to enamel and dentin: current status and future chllenges
9. Long-term durability of dentin bonds made with a self-etching primer, in vivo10.1177/00220345990780041101 ↗
10. Relationship between bond strengths and microleakage: evaluation of a new assessment method
11. Nanoleakage of dentin adhesive systems bonded to carisolv-treated dentin
12. Distribution of nanofillers from a simplified-step adhesive in acid-conditioned dentin
13. Quantitative analysis of the dentin adhesive interface by auger spectroscopy10.1177/00220345960750040501 ↗
14. In vitro effect of nanoleakage expression on resin–dentin bond strengths analyzed by microtensile bond test, SEM/EDS TEM10.1016/j.biomaterials.2004.01.009 ↗
15. Bonding of a self-etching primer to non-carious cervical sclerotic dentin: interfacial ultrastructure and microtensile bond strength evaluation
16. Nanoleakage at the dentin adhesive interface vs μ-tensile bond strength
17. How can nanoleakage occur in self-etching systems that demineralize and infiltrate simultaneously?
18. Fluid movement across the resin–dentin interface during and after bonding10.1177/154405910408301104 ↗
19. Evaluation of silver methenamine method for nanoleakage10.1016/j.jdent.2004.01.010 ↗
20. A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives10.1016/j.biomaterials.2004.04.003 ↗
21. Comparative study on adhesive performance of functional monomers10.1177/154405910408300604 ↗
22. Have dentin adhesives become too hydrophilic?
23. Single-step adhesives are permeable membranes10.1016/S0300-5712(02)00064-7 ↗
24. Effects of HEMA/solvent combinations on bond strength to dentin10.1177/154405910308200805 ↗
25. Adhesive phase separation at the dentin interface under wet bonding conditions10.1002/jbm.10364 ↗
26. Micromorphological spectrum from overdrying to overwetting acid-conditioned dentin in water-free, acetone-based, single-primer/adhesives10.1016/S0109-5641(96)80029-7 ↗
27. Monomer-solvent phase separation in one-step self-etch adhesives10.1177/154405910508400214 ↗
28. Ultrastructural study of a glass ionomer-based, all-in-one adhesive10.1016/S0300-5712(01)00046-X ↗
29. Nanoleakge types and potential implications: evidence from unfilled and filled adhesive with the same resin composition
30. Correlation among dentin depth, permeability, and bond strength of adhesive resins10.1016/0109-5641(90)90044-F ↗
31. Effect of occlusal load cycling on the marginal integrity of adhesive class V restorations
32. Effects of regional enamel and prism orientation on resin bonding
33. Shear bond stability of current adhesive systems to enamel
34. Effect of various pretreatments for dentin bonding on dentin permeability
35. Relationship between nano-leakage and long-term durability of dentin bonds
36. Long-term durability of resin dentin interface: nano-leakage vs. microtensile bond strength