Effect of the composite photoactivation mode on microtensile bond strength and Knoop microhardness
Source abstract
Abstract
Objective This study evaluated the effect of the composite photoactivation mode on microtensile bond strength and Knoop microhardness. Methods Standard class I cavities (3 x 4 x 3mm) were restored with two adhesives systems, Single Bond (SB) and Clearfil SE Bond (CE), and the TPH composite. The photoactivation of the composite was carried out using three modes: Conventional (CO: 400 mW/cm(2) x 40s), Soft-Start (SS: 100 mW/cm(2) x 10s+600 mW/cm(2) x 30s) and Pulse-Delay (PD: 100 mW/cm(2) x 3s+3 min wait+600 mW/cm(2) x 37s). For the microtensile test, beams obtained from the buccal wall bond interface were tested under tension at 0.5mm/min crosshead speed until failure. For the microhardness test, the restorations were sectioned in the mesio-distal direction and indentations were made on the internal composite surface of each half at three different depths. Data of two tests were analyzed using two-way ANOVA and LSMeans (alpha=0.05). Results In the microtensile test, SS presented the highest values. PD presented intermediate values without differing significantly from the other modes. For adhesives, SB presented the highest values. In the microhardness test, PD presented the highest values, differing significantly from SS. CO presented intermediate values but without any statistical difference from the others. The SS-CE interaction presented the lowest values with statistical differences from all the others. Significance By the SS technique, the highest bond strength was obtained. However, this technique made it possible for the adhesive system to intervene with the hardness of the composite.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Mechanical Behavior of Composites · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Clinical results and new developments of direct posterior restorations
2. Direct and indirect adhesive restorative materials: a review
3. Linear and volumetric polymerization shrinkage of restorative materials
4. Polymerization shrinkage of visible-light-cured composites
5. Relating composite contraction stress to leakage in classs V cavities
6. In vitro measurement of cuspal strain and displacement in composite restored teeth10.1016/S0300-5712(96)00047-4 ↗
7. Contolling and understanding the polymerization shrinkage-induced stress in light-cured composites
8. Light intensity effects on resin-composite degree of conversion and shrinkage strain10.1016/S0109-5641(00)00020-8 ↗
9. Wear and marginal breackdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
10. Elastic modului and visco-elastic relaxation10.1016/0300-5712(94)90199-6 ↗
11. Relaxation of polymerization contraction stresses by flow in dental composite10.1177/00220345840630021001 ↗
12. Setting stress in composite resin in relation to configuration of the restoration10.1177/00220345870660110601 ↗
13. A light curing method for improving marginal sealing and cavity wall adaptation of resin composite restorations10.1016/S0109-5641(00)00095-6 ↗
14. Class I occlusal composite resin restorations: in vivo post-operative sensitivity, wall-adaptation and microleakage
15. The competition between the composite-dentin bond strenght and the polymerization contraction stress10.1177/00220345840630121101 ↗
16. Reduced light energy density decreases post-gel contraction while maintaining degree of conversion in composites10.1016/S0300-5712(97)00048-1 ↗
17. Comparison of polymerization contraction stresses between self-and light-curing composites10.1016/S0300-5712(98)00065-7 ↗
18. Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface10.1111/j.1600-0722.1995.tb00033.x ↗
19. Marginal adaptation of a restorative resin polymerized at reduced rate
20. Physical properties and gap formation of light-cured composites with and without ‘soft-start-polymerization’10.1016/S0300-5712(96)00044-9 ↗
21. Post-gel shrinkage with pulse activation and sof-start polymerization
22. How wet should dentin be? Comparison of methods to remove excess water during moist bonding
23. Influence of pulse-delay curing on softening of polymer S structures10.1177/00220345010800061801 ↗
24. Reduction of polymerization contraction stress for dental composites by two-step light-activation10.1016/S0109-5641(01)00066-5 ↗
25. Effects of dentin depth and cavity configuration on bond strength10.1177/00220345990780041001 ↗
26. Effect of different intensity light curing modes on microleakage of two resin composite restorations
27. Adhesion testing of dentin bonding agents: a review10.1016/0109-5641(95)80046-8 ↗
28. Microtensile bond strengths of an etch&rinse and self-etch adhesive to enamel and dentin as a function of surface treatment
29. Effect of self-etching primer vs phosphoric acid etchant on bonding to bur-prepared dentin
30. Nakabayashi · 1998
31. Effects of different burs on dentin bond strengths of self-etching primer bonding systems
32. Contraction force rate of polymer composites is linearly correlated with irradiance10.1016/j.dental.2003.11.004 ↗
33. Effect of sequential versus continuous irradiation of a light-cured resin composite on shrinkage, viscosity, adhesion, and degree of polymerization
34. The effect of cure rate on the mechanical properties of dental resins10.1016/S0109-5641(01)00010-0 ↗
35. Two-step curing: influence on conversion and softening of a dental polymer10.1016/S0109-5641(02)00091-X ↗
36. Influence of curing modes on crosslink density in polymer structures10.1016/j.jdent.2004.01.012 ↗
37. Polymerization shrinkage: effects of boundary conditions and filling technique of resin composite restorations10.1016/j.jdent.2004.02.010 ↗
38. Effects Of Cavity Configuration on Composite Restoration
39. Effect of adhesive layer properties on stress distribution in composite-a 3D finite element analysis10.1016/S0109-5641(01)00042-2 ↗