journal article·2017-03

Laboratory mechanical parameters of composite resins and their relation to fractures and wear in clinical trials—A systematic review

Siegward D. Heintze, Nicoleta Ilie, Reinhard Hickel, Alessandra Reis, Alessandro Loguercio, Valentin Rousson

Dental Materials· Volume 33· Issue 3
Publisher page

Abstract

Objective To evaluate a range of mechanical parameters of composite resins and compare the data to the frequency of fractures and wear in clinical studies. Methods Based on a search of PubMed and SCOPUS, clinical studies on posterior composite restorations were investigated with regard to bias by two independent reviewers using Cochrane Collaboration's tool for assessing risk of bias in randomized trials. The target variables were chipping and/or fracture, loss of anatomical form (wear) and a combination of both (summary clinical index). These outcomes were modelled by time and material in a linear mixed effect model including random study and experiment effects. The laboratory data from one test institute were used: flexural strength, flexural modulus, compressive strength, and fracture toughness (all after 24-h storage in distilled water). For some materials flexural strength data after aging in water/saliva/ethanol were available. Besides calculating correlations between clinical and laboratory outcomes, we explored whether a model including a laboratory predictor dichotomized at a cut-off value better predicted a clinical outcome than a linear model. Results A total of 74 clinical experiments from 45 studies were included involving 31 materials for which laboratory data were also available. A weak positive correlation between fracture toughness and clinical fractures was found (Spearman rho=0.34, p=0.11) in addition to a moderate and statistically significant correlation between flexural strength and clinical wear (Spearman rho=0.46, p=0.01). When excluding those studies with "high" risk of bias (n=18), the correlations were generally weaker with no statistically significant correlation. For aging in ethanol, a very strong correlation was found between flexural strength decrease and clinical index, but this finding was based on only 7 materials (Spearman rho=0.96, p=0.0001). Prediction was not consistently improved with cutoff values. Significance Correlations between clinical and laboratory outcomes were moderately positive with few significant results, fracture toughness being correlated with clinical fractures and flexural strength with clinical wear. Whether artificial aging enhances the prognostic value needs further investigations.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Trauma and Treatments · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Resin-based composite performance: are there some things we can’t predict?10.1016/j.dental.2012.06.013 ↗
2. Relevance of in vitro tests of adhesive and composite dental materials, a review in 3 parts. Part 1: approval requirements and standardized testing of composite materials according to ISO specifications
3. Heintze · 2010
4. Clinical effectiveness of direct class II restorations—a meta-analysis
5. Clinical effectiveness of direct anterior restorations—a meta-analysis10.1016/j.dental.2015.01.015 ↗
6. Longevity of posterior composite restorations: a systematic review and meta-analysis10.1177/0022034514544217 ↗
7. Survival of direct resin restorations in posterior teeth within a 19-year period (1996–2015): a meta-analysis of prospective studies10.1016/j.dental.2015.05.004 ↗
8. Longevity of posterior resin composite restorations in adults—a systematic review10.1016/j.jdent.2015.05.001 ↗
9. Patient risk factors' influence on survival of posterior composites10.1177/0022034513484337 ↗
10. Clinical wear performance of eight experimental dental composites over three years determined by two measuring methods10.1034/j.1600-0722.2001.00064.x ↗
11. Jäggi · 2015
12. Fatigue resistance of denture teeth10.1016/j.jmbbm.2015.08.034 ↗
13. Factors involved in mechanical fatigue degradation of dental resin composites10.1177/0022034513490734 ↗
14. ISO, 2009. Dentistry—polymer-based filling, restorative and luting materials. International Standard; No. 4049:1–27.
15. Use of standards in papers published in dental journals10.1590/S0103-64402012000500001 ↗
16. ISO, 2001. Dental materials—guidance on testing of wear. Part 2: wear by two-and/or three body contact. Technical Specification; No. 14569–2.
17. How to qualify and validate wear simulation devices and methods10.1016/j.dental.2006.02.002 ↗
18. European Directorate for the Quality of Medicines and Health Care, 2011. Qualification of Equipment—Core Document (PA/PH/OMCL (08) 73 2R). Quality Management Guidelines.
19. Roulet · 1987
20. Degradation, fatigue, and failure of resin dental composite materials10.1177/154405910808700802 ↗
21. The effects of thermocycling on the flexural strength and flexural modulus of modern resin-based filling materials10.1016/j.dental.2005.09.005 ↗
22. 12-year survival of composite vs amalgam restorations10.1177/0022034510376071 ↗
23. Longevity of repaired restorations: a practice based study10.1016/j.jdent.2012.06.007 ↗
24. Investigations on mechanical behaviour of dental composites10.1007/s00784-009-0258-4 ↗
25. Fracture toughness of dental restorative materials10.1007/s00784-011-0525-z ↗
26. Correlation between fracture properties and clinical performance of composite resins in class IV cavities10.1111/j.1834-7819.1990.tb03027.x ↗
27. Berger · 2005
28. Research gaps identified during systematic reviews of clinical trials: glass-ionomer cements10.1186/1472-6831-12-18 ↗
29. Bias and small-study effects influence treatment effect estimates: a meta-epidemiological study in oral medicine10.1016/j.jclinepi.2014.04.002 ↗
30. FDI World Dental Federation—clinical criteria for the evaluation of direct and indirect restorations. Update and clinical examples
31. Recommendations for conducting controlled clinical studies of dental restorative materials (Science Committee Project 2/98—FDI World Dental Federation)
32. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials10.1136/bmj.d5928 ↗
33. Investigations towards nano-hybrid resin-based composites10.1007/s00784-012-0689-1 ↗
34. Macro-, micro- and nano-mechanical investigations on silorane and methacrylate-based composites10.1016/j.dental.2009.02.005 ↗
35. The mechanical stability of nano-hybrid composites with new methacrylate monomers for matrix compositions10.1016/j.dental.2011.11.007 ↗
36. ASTM, 1989. Standard Test Method for Plane Strain Fracture Toughness of Metallic Materials.
37. Fracture mechanics parameters for failure prediction of composite resins10.1177/00220345880670060601 ↗
38. Developing meaningful systematic review of CAD/CAM reconstructions and fiber-reinforced composites10.1111/j.1600-0501.2007.01443.x ↗
39. Longevity of posterior composite restorations: not only a matter of materials10.1016/j.dental.2011.09.003 ↗
40. Buonocore memorial lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition
41. Recommendations for conducting controlled clinical studies of dental restorative materials10.1007/s00784-006-0095-7 ↗
42. Investigation of the correlation between the different mechanical properties of resin composites10.4012/dmj.2012-178 ↗
43. Modulus of resilience as predictor for clinical wear of restorative resins10.1016/0109-5641(92)90071-J ↗
44. Predictors of clinical wear of restorative dental composite materials
45. Dynamic mechanical thermal properties of the dental light-cured nanohybrid composite Kalore, GC: effect of various food/oral simulating liquids10.1016/j.dental.2014.11.008 ↗
46. Thermal cycling procedures for laboratory testing of dental restorations10.1016/S0300-5712(98)00037-2 ↗
47. In vitro aging of dental composites in water—effect of degree of conversion, filler volume, and filler/matrix coupling10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.0.CO;2-F ↗
48. Leaching and mechanical properties characterization of dental composites10.1002/jbm.b.30074 ↗
49. Filler leachability of composites stored in distilled water or artificial saliva10.1177/00220345960750091201 ↗
50. Filler particle leachability of experimental dental composites10.1034/j.1600-0722.2000.00919.x ↗
51. Influence of pulse-delay curing on softening of polymer structures10.1177/00220345010800061801 ↗
52. Sorption kinetics of ethanol/water solution by dimethacrylate-based dental resins and resin composites10.1002/jbm.b.30655 ↗
53. Volumetric dimensional changes of dental light-cured dimethacrylate resins after sorption of water or ethanol10.1016/j.dental.2007.12.009 ↗
54. Influence of curing modes on crosslink density in polymer structures10.1016/j.jdent.2004.01.012 ↗