journal article·2024-11

Fatigue lifetime of reduced-diameter implants placed in different bone models

Pedro Henrique Wentz Tretto, Jason Alan Griggs, Kartikeya Singh Jodha, Yuanyuan Duan, Susana María Salazar Marocho, Alvaro Della Bona

Dental Materials· Volume 40· Issue 11
Publisher page

Abstract

Objectives This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. Methods Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter × 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servo-hydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. Result The implants exhibited high stability quotient values (75.07 ± 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. Significance Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone health and osteoporosis research · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Influence of diameter and length of implant on early dental implant failure10.1016/j.joms.2009.10.002 ↗
2. New approach towards mini dental implants and small-diameter implants: an option for long-term prostheses
3. The influence of implant diameter on its survival: a meta-analysis based on prospective clinical trials10.1902/jop.2013.130043 ↗
4. Clinical outcome of narrow diameter implants: a retrospective study of 510 implants10.1902/jop.2008.070248 ↗
5. Relationship between sponsorship and failure rate of dental implants: a systematic approach10.1371/journal.pone.0010274 ↗
7. Retrieval analyses of a blade implant after 231 months of clinical function10.1097/00008505-199200110-00004 ↗
8. Hollow implants retrieved for fracture: a light and scanning electron microscope analysis of 4 cases10.1902/jop.1998.69.2.185 ↗
9. A close-up look at an implant fracture: a case report
10. Fracture of dental implants: literature review and report of a case10.1097/00008505-200204000-00014 ↗
11. Clinical management and microscopic characterisation of fatigue-induced failure of a dental implant. Case report.10.1186/1746-160X-2-18 ↗
12. Fatigue lifetime prediction of a reduced-diameter dental implant system: numerical and experimental study10.1016/j.dental.2018.06.002 ↗
13. ADM guidance-ceramics: fatigue principles and testing10.1016/j.dental.2017.09.006 ↗
14. Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection10.1016/j.dental.2018.09.001 ↗
15. Effect of irrigation and stainless steel drills on dental implant bed heat generation10.1007/s10856-015-5412-8 ↗
16. The effect of irrigation on osteotomy depth and bur diameter
17. Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography10.1111/j.1600-0501.2009.01905.x ↗
18. Evaluation of peri-implant buccal bone by computed tomography: an experimental study10.1111/clr.12663 ↗
19. Effect of simplifying drilling technique on heat generation during osteotomy preparation for dental implant10.1097/ID.0000000000000692 ↗
20. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex vivo study10.1111/clr.12827 ↗
21. Patient selection and preparation
22. Radiographic alveolar bone assessment in correlation with primary implant stability: a systematic review and meta-analysis10.1111/clr.14195 ↗
23. Bone volume fraction explains the variation in strength and stiffness of cancellous bone affected by metastatic cancer and osteoporosis10.1007/s00223-008-9174-x ↗
24. Structural and radiological parameters for the characterization of jawbone10.1111/j.1600-0501.2005.01204.x ↗
25. MicroCT-based evaluation of the trabecular bone quality of different implant anchorage sites for masticatory rehabilitation of the maxilla10.1016/j.jcms.2015.04.008 ↗
26. Micro-computed tomography assessment of human alveolar bone: bone density and three-dimensional micro-architecture10.1111/cid.12109 ↗
27. Bone volume fraction and structural parameters for estimation of mechanical stiffness and failure load of human cancellous bone samples; in-vitro comparison of ultrasound transit time spectroscopy and X-ray μCT10.1016/j.bone.2017.11.021 ↗
28. Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review10.1111/cid.12565 ↗
29. The clinical significance of implant stability quotient (ISQ) measurements: a literature review10.1016/j.jobcr.2020.07.004 ↗
30. Effect of bone remodeling on dental implant fatigue limit predicted using 3D finite element analysis
31. Bone quality effect on short implants in the edentulous mandible: a finite element study10.1186/s12903-022-02164-8 ↗
32. Effect of dental implant diameter on fatigue performance. Part II: failure analysis10.1111/j.1708-8208.2012.00476.x ↗
33. Identification of failure mechanisms in retrieved fractured dental implants10.1016/j.engfailanal.2014.01.002 ↗
34. Failed dental implant: when titanium fractures10.3390/diagnostics13122123 ↗