Lifetime prediction of veneered versus monolithic lithium disilicate crowns loaded on marginal ridges
Source abstract
Abstract
Objective To evaluate the probability of survival of monolithic and porcelain veneered lithium disilicate crowns comprised by a conventional or modified core when loaded on marginal ridges. Methods Lithium disilicate molar crowns (n=30) were fabricated to be tested at mesial and distal marginal ridges and were divided as follows: (1) bilayered crowns with even-thickness 0.5mm framework (Bi-EV); (2) bilayered crowns with modified core design (Bi-M-lingual collar connected to proximal struts), and: (3) monolithic crowns (MON). After adhesively cemented onto composite-resin prepared replicas, mesial and distal marginal ridges of each crown (n=20) were individually cyclic loaded in water (30-300N) with a ceramic indenter at 2Hz until fracture. The 2-parameter Weibull was used to calculate the probability of survival (reliability) (90% 2-sided confidence bounds) at 1, 2, and 3 million cycles and mean life. Results The reliability at 1 and 2 million cycles was significantly higher for MON (47% and 19%) compared to Bi-EV (20% and 4%) and Bi-M (17% and 2%). No statistical difference was found between bilayered groups. Only the MON group presented crown survival (7%) at 3 million cycles. The mean life was highest for MON (1.73E+06), lowest for Bi-M (573,384) and intermediate for Bi-E (619,774). Fractographic analysis showed that the fracture originated at the occlusal surface. The highest reliability was found for MON crowns. The modified framework design did not improve the fatigue life of crowns. Significance Monolithic lithium disilicate crowns presented higher probability of survival and mean life than bilayered crowns with modified framework design when loaded at marginal ridges.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (80)
Show source-provided references
1. Comparative reliability analyses of zirconium oxide and lithium disilicate restorations in vitro and in vivo10.14219/jada.archive.2011.0336 ↗
2. Clinical results of lithium-disilicate crowns after up to 9 years of service10.1007/s00784-012-0700-x ↗
3. CAD/CAM-fabricated ceramic implant-supported single crowns made from lithium disilicate: final results of a 5-year prospective cohort study10.1111/cid.12508 ↗
4. Criteria for the selection of restoration materials
5. Modified Y-TZP core design improves all-ceramic crown reliability10.1177/0022034510384617 ↗
6. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
7. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results
8. Weibull analysis and flexural strength of hot-pressed core and veneered ceramic structures10.1016/S0109-5641(03)00010-1 ↗
9. Role of investment interaction layer on strength and toughness of ceramic laminates10.1016/j.dental.2003.08.006 ↗
10. Residual stresses in bilayer dental ceramics10.1016/j.biomaterials.2004.08.025 ↗
11. Influence of veneer application on fracture behavior of lithium-disilicate-based ceramic crowns10.1016/j.dental.2012.02.011 ↗
12. Influence of veneer and cyclic loading on failure behavior of lithium disilicate glass-ceramic molar crowns10.1016/j.dental.2013.11.001 ↗
13. Reliability of reduced-thickness and thinly veneered lithium disilicate crowns10.1177/0022034511433504 ↗
14. Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics10.1016/j.dental.2005.11.014 ↗
15. In the service of the crown10.1002/germ.200290010 ↗
16. A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report10.14219/jada.archive.2010.0355 ↗
17. A preliminary study on the short-term efficacy of chairside computer-aided design/computer-assisted manufacturing- generated posterior lithium disilicate crowns
18. Mechanical fatigue of a feldspathic dental procelain10.1016/0109-5641(93)90071-W ↗
19. Stress fatigue: basic principles and prosthodontic implications
20. Customization of milled zirconia copings for all-ceramic crowns: a clinical report10.1016/S0022-3913(08)00028-0 ↗
21. Complete and partial contour zirconia designs for crowns and fixed dental prostheses: a clinical report10.1016/S0022-3913(11)60112-1 ↗
22. Failure analysis of ceramic clinical cases using qualitative fractography
23. Clinical risk factors related to failures with zirconia-based restorations: an up to 9-year retrospective study10.1016/j.jdent.2013.10.009 ↗
24. Three- to nine-year survival estimates and fracture mechanisms of zirconia- and alumina-based restorations using standardized criteria to distinguish the severity of ceramic fractures10.1007/s00784-015-1455-y ↗
25. Tooth preparation an the design of metal substructures
26. Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results10.1111/j.1365-2842.2009.01969.x ↗
27. Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns10.1016/j.dental.2012.11.012 ↗
28. Fatigue life and failure modes of crowns systems with a modified framework design10.1016/j.jdent.2010.04.011 ↗
29. Slow cooling protocol improves fatigue life of zirconia crowns10.1016/j.dental.2014.10.005 ↗
30. Conventional and modified veneered zirconia vs. metalloceramic: fatigue and finite element analysis10.1111/j.1532-849X.2012.00861.x ↗
31. Lifetime prediction of zirconia and metal ceramic crowns loaded on marginal ridges10.1016/j.dental.2016.09.004 ↗
32. Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study10.1007/s00784-017-2142-y ↗
33. Eleven-year retrospective survival study of 275 veneered lithium disilicate single crowns10.11607/prd.2150 ↗
34. Observations on its development from infancy to old age International Journal of Orthodontia10.1016/S0099-6963(27)90126-4 ↗
35. Nature of contacts in centric occlusion in 32 adults10.1177/00220345710500013201 ↗
36. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars10.1111/j.1469-7580.2011.01396.x ↗
37. Comparison of occlusal loading conditions in a lower second premolar using three-dimensional finite element analysis10.1007/s00784-013-0973-8 ↗
38. Strains in the marginal ridge during occlusal loading10.1111/j.1834-7819.2002.tb00332.x ↗
39. Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach10.1016/j.dental.2008.09.001 ↗
40. Three-year clinical evaluation of two ceramic crown systems: a preliminary study10.1016/S0022-3913(10)60010-8 ↗
41. All-ceramic systems: laboratory and clinical performance10.1016/j.cden.2011.01.005 ↗
42. Eight-year outcome of posterior inlay-retained all-ceramic fixed dental prostheses10.1016/j.jdent.2010.07.012 ↗
43. Damage maps for layered ceramics under simulated mastication10.1177/154405910808700706 ↗
44. Correlation of in vitro fatigue data and in vivo clinical performance of a glassceramic material10.1016/j.dental.2007.01.011 ↗
45. Fractographic features of glass-ceramic and zirconia-based dental restorations fractured during clinical function10.1111/eos.12127 ↗
46. Fractographic ceramic failure analysis using the replica technique10.1016/j.dental.2006.12.002 ↗
47. Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses10.1007/s00784-011-0575-2 ↗
48. Chipping resistance of graded zirconia ceramics for dental crowns10.1177/0022034511434356 ↗
49. Modeling of water absorption induced cracks in resin-based composite supported ceramic layer structures10.1002/jbm.b.30852 ↗
50. HotWire R. Determining the Sample Size for a Life Test Based on the Shape Parameter of the Weibull Distribution. Resources WcRE, editor. Issue 126 ed. https://www.weibull.com/hotwire/issue126/hottopics126.htm2018.
51. Meeker · 2014
52. Nelson · 2004
53. AG IV. IPS e. max Press Monolithic Solutions. Ivoclar Vivadent AG, Schaan/Liechtenstein. 2017.
54. In vitro wear of four ceramic materials and human enamel on enamel antagonist10.1111/eos.12272 ↗
55. Intercuspal contacts of the natural dentition in centric occlusion10.1016/0022-3913(81)90104-9 ↗
56. Tooth contact location in intercuspal position
57. Current procedures in fixed prosthodontics10.1016/S0011-8532(22)01485-9 ↗
58. Study of the number of occlusal contacts in maximum intercuspation before orthodontic treatment in subjects with Angle Class I and Class II Division 1 malocclusion10.1590/S2176-94512012000100017 ↗
59. A rationale for a simplified occlusal design in restorative dentistry: historical review and clinical guidelines10.1016/S0022-3913(05)80159-3 ↗
60. Quinn · 2007
61. Time-dependent fracture probability of bilayer, lithium-disilicate-based, glass-ceramic, molar crowns as a function of core/veneer thickness ratio and load orientation10.1016/j.dental.2013.08.206 ↗
62. Monolithic CAD/CAM lithium disilicate versus veneered Y-TZP crowns: comparison of failure modes and reliability after fatigue
63. Prospective clinical split-mouth study of pressed and CAD/CAM all-ceramic partial-coverage restorations: 7-year results10.11607/ijp.3043 ↗
64. Clinical evaluation of 860 anterior and posterior lithium disilicate restorations: retrospective study with a mean follow-up of 3 years and a maximum observational period of 6 years10.11607/prd.1769 ↗
65. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics10.1016/j.dental.2003.05.003 ↗
66. Phenomena and mechanisms of crack propagation in glass-ceramics10.1016/j.jmbbm.2007.11.005 ↗
67. Ceramics for dental applications: a review
68. A critical perspective on mechanical testing of implants and prostheses10.1177/0022034515624445 ↗
69. Relative flexural strength of dental restorative ceramics10.1016/0109-5641(90)90026-B ↗
70. Design of gold supporting structures for fused porcelain restorations10.1016/0022-3913(66)90015-1 ↗
71. Practical considerations and design of the porcelain fused to metal10.1016/0022-3913(62)90137-3 ↗
72. Effect of framework design on crown failure10.1111/j.1600-0722.2008.00608.x ↗
73. Fracture strength of monolithic all-ceramic crowns made of high translucent yttrium oxide-stabilized zirconium dioxide compared to porcelain-veneered crowns and lithium disilicate crowns10.3109/00016357.2013.822098 ↗
74. Influence of veneer application on failure behavior and reliability of lithium disilicate glass-ceramic molar crowns
75. In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses10.1007/s00784-013-1062-8 ↗
76. Fracture resistance of a selection of full-contour all-ceramic crowns: an in vitro study10.11607/ijp.3815 ↗
77. Fractographic analyses of all-ceramic crowns: a study of 27 clinically fractured crowns10.1016/j.dental.2013.03.018 ↗
78. Fractographic failure analysis of a Procera AllCeram crown using stereo and scanning electron microscopy10.1016/j.dental.2008.01.002 ↗
79. Fracture of porcelain-veneered structures in fatigue10.1177/154405910708600207 ↗
80. Materials design of ceramic-based layer structures for crowns10.1177/154405910208100615 ↗