journal article·2013-02

Thermal-induced residual stresses affect the lifetime of zirconia–veneer crowns

Renan Belli, Roland Frankenberger, Andreas Appelt, Johannes Schmitt, Luiz N. Baratieri, Peter Greil, Ulrich Lohbauer

Dental Materials· Volume 29· Issue 2
Publisher page

Abstract

Objectives The purposes of this study were to investigate the effects of thermal residual stresses on the reliability and lifetime of zirconia-veneer crowns. Methods One hundred and twenty eight second upper premolar zirconia-veneer crowns were manufactured for testing the initial strength (n=64) and under cyclic fatigue (n=64). Zirconia copings (YZ Cubes, VITA Zahnfabrik, CTE: alphac=10.5 ppm/°C) were milled using a Cerec3 InLab (Sirona) machine and sintered to a final thickness of 0.7 mm. Sixty-four copings were sandblasted with 105 μm alumina particles (15 s, 3 cm distance, 45° angle, 0.4 MPa pressure) in order to trigger a tetragonalmonoclinic transformation and to produce a rough surface. The copings were veneered using two different porcelains (VM9, VITA Zahnfabrik, CTE: alphaVM9=9.1 ppm/°C, Lava Ceram, 3M ESPE, CTE: alphaLava=10.2 ppm/°C) so to result in crowns with either high thermal mismatch (+1.4 ppm/°C with VM9) and low thermal mismatch (+0.3 ppm/°C with Lava Ceram). The porcelains were applied by the same operator and fired (VITA Vacumat 4000) according to the firing schedules defined by the manufacturers to a final thickness of 1.4mm (total crown thickness=2.1mm, core/veneer ratio=0.5). After the last glaze firing the crowns were cooled following a fast (600°C/min) or a slow (30°C/min) cooling protocol. The glazed crowns were submitted to a sliding-motion (0.7 mm lateral movement) cyclic fatigue in a chewing simulator (SD Mechatronik) under 20 kg (~200 N load) weight until failure (chipping) (n=16). The other half of the crowns were subjected to a compressive loading test in an universal testing machine (Instron model 4240) until failure at a cross-head speed of 0.75 mm/min (n=16). The failure probability for initial strength and cyclic fatigue was performed using a Weibull distribution approach at a scale factor of n=16. Results The compressive strength test showed a low sensitivity to detect reliability variations regarding thermal stresses created within the veneer layer of tested crowns. For cyclic fatigue, slow cooling resulted in statistically higher cycles to failure only for the crowns that presented a high thermal mismatch between core and veneer (VM9 group). Comparisons between veneers with high or low thermal mismatches showed statistically higher sigma0 for Lava Ceram-veneered crowns only when the groups were fast-cooled. Significance Minimizing the thermal residual stresses within the veneer through the use of a veneer with a closer CTE to the zirconia delays the failure of zirconia-veneer crowns. Slow-cooling increases the lifetime of crowns presenting large differences in CTE between the zirconia core and the veneering porcelain.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Recycling and utilization of industrial and municipal waste in materials production

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach10.1016/j.dental.2008.09.001 ↗
2. Fractographic analysis of a dental zirconia framework: a case study on design issues10.1016/j.jmbbm.2010.07.004 ↗
3. Clinical trials in zirconia: a systematic review
4. A systematic review of the survival and complication rates of all-ceramic and metal–ceramic reconstructions after an observation period of at least 3 years, part II: fixed dental prostheses10.1111/j.1600-0501.2007.01468.x ↗
5. Subcritical crack growth behavior and life data analysis of two types of dental Y-TZP ceramics10.1016/j.dental.2012.04.010 ↗
6. Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges10.1016/j.dental.2005.12.008 ↗
7. Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures
8. Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study
9. A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
10. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs
11. A systematic review of the survival and complication rates of all-ceramic and metal–ceramic reconstructions after an observation period of at least 3 years, part I: single crowns10.1111/j.1600-0501.2007.01467.x ↗
12. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
13. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
14. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study10.1016/j.prosdent.2006.08.010 ↗
15. All-ceramic two- to five-unit implant-supported reconstructions, a randomized, prospective clinical trial
16. 10-year clinical outcomes of fixed dental prostheses with zirconia frameworks
17. Fracture of porcelain-veneered structures in fatigue10.1177/154405910708600207 ↗
18. Randomized controlled clinical trial of zirconia–ceramic and metal–ceramic posterior fixed dental prostheses: a 3-year follow-up
19. Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review
20. Calculation of interfacial stress in porcelain-fused-to-metal systems10.1177/00220345800590110801 ↗
21. Shear stress measurements at a dental porcelain–gold bond interface10.1177/00220345720510026301 ↗
22. Transient and residual stresses in dental porcelains as affected by cooling rates10.4012/dmj.8.9 ↗
23. Viscoelastic stress analysis of thermally compatible and incompatible metal–ceramic systems10.1016/S0109-5641(98)00031-1 ↗
24. Evaluation of thermal compatibility between core and veneer dental ceramics using shear bond strength test and contact angle measurement10.1016/j.dental.2010.03.019 ↗
25. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures10.1016/j.actbio.2008.12.016 ↗
26. Kinetics of structural relaxation of glass-forming melts10.1016/0040-6031(95)02654-1 ↗
27. Pressed ceramics onto zirconia, part 2: indentation fracture and influence of cooling rate on residual stresses10.1016/j.dental.2011.08.003 ↗
28. Thermal gradients and residual stresses in Y-TZP frameworks10.1016/j.dental.2011.08.001 ↗
29. Microtensile bond strength of different components of core veneered all-ceramic restorations, part II: zirconia veneering ceramics10.1016/j.dental.2005.11.014 ↗
30. Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites10.1016/j.dental.2008.09.003 ↗
31. SEM observations of porcelain Y-TZP interface10.1016/j.dental.2009.01.006 ↗
32. XRD2 micro-diffraction analysis of the interface between Y-TZP and veneering porcelain: role of application methods10.1016/j.dental.2010.02.002 ↗
33. In vitro evaluation of a mechanical testing chewing simulator10.1016/j.dental.2008.09.010 ↗
34. EN-843/5. Mechanical testing of monolithic ceramics at room temperature. Part 5: Statistical treatment; 1997.
35. Microstructural analysis of surface treated Y-TZP zirconia using TEM10.1016/j.dental.2011.08.548 ↗
36. A photoelastic assessment of residual stresses in zirconia–veneer crowns10.1177/0022034511435100 ↗
37. Sliding contact fatigue damage in layered ceramic structures10.1177/154405910708601105 ↗
38. Hydraulically pumped cone fracture in brittle solids10.1016/j.actamat.2005.05.026 ↗
39. Off-axis sliding contact reliability and failure modes of veneered alumina and zirconia10.1016/j.dental.2009.01.093 ↗
40. Transverse fracture of brittle bilayers: relevance to failure of all-ceramic dental crowns10.1002/jbm.b.30511 ↗
41. Laboratory simulation of Y-TZP all-ceramic crown clinical failures10.1177/0022034509333968 ↗
42. Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns10.1016/j.jdent.2009.08.003 ↗
43. Exponential structural relaxation of high purity silica glass10.1016/j.jnoncrysol.2008.07.005 ↗
44. The effects of viscoelastic parameters on residual stress development in a zirconia/glass bilayer dental ceramic10.1016/j.dental.2008.01.004 ↗
45. Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems10.1016/j.dental.2006.06.036 ↗
46. Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns10.4012/dmj.26.766 ↗
47. Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks10.1016/j.dental.2008.08.001 ↗
48. Transient modelling of thermal processing for ceramic prostheses