Reporting of light irradiation conditions in 300 laboratory studies of resin-composites
Source abstract
Abstract
Objective To evaluate how the light delivered to resin-composites was described in recent articles. Method PubMed was searched for 300 articles published between January 2017 and May 2018 with keywords relating to photocuring of dental materials. The articles examined a wide range of resin-composite properties and performance. For each article, the information provided about the light curing unit (LCU), the light curing conditions and the characteristics and quantity of the light used in the study were recorded. Specifically, the type of LCU used; the irradiance; how the irradiance was measured; the exposure times; whether the light energy (radiant exposure) received by the specimen was determined, or if only the light output at the LCU tip was measured; whether the distance between the tip of the LCU and the specimen was reported; and whether the emission spectrum from the LCU was reported. Where possible, the resin manufacturer's minimum energy requirement (MER: the product of the recommended minimum exposure time and irradiance) was compared to the radiant exposure delivered to the specimen. Results Of the 300 articles examined, 217 were published in 2017 and 83 in 2018. Of these articles, 130 (43%) were found in open access journals, and 170 (57%) were in subscription-based journals. The name of the LCU used was not provided in 31 articles, 14 articles did not provide the exposure time, and 227 articles did not report the distance to the specimen. An irradiance value was reported in 231 articles, but this was the irradiance received by the specimen in only 48 instances. The emission spectrum from the LCU was reported in 15 articles. There was a large range in the radiant exposures from below 10J/cm2 to greater than 100J/cm2. Significance The majority of articles from 2017 and early 2018 did not include sufficient description of the characteristics and quantity of the light received by the resin-composite specimens to allow the study to be replicated. It is recommended that future articles should report: (1) the identity of the LCU used; (2) the radiant exposure received by the specimen (J/cm2); and (3) appropriate reference to the emission spectrum from the LCU.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Laser Applications in Dentistry and Medicine · Photodynamic Therapy Research Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. FDI policy statement on dental amalgam and the Minamata Convention on Mercury: adopted by the FDI General Assembly: 13 September 2014, New Delhi, India10.1111/idj.12151 ↗
2. Managing the phase-down of amalgam: part II. Implications for practising arrangements and lessons from Norway10.1038/sj.bdj.2013.788 ↗
3. Visible light curing devices — irradiance and use in 302 German Dental Offices
4. Light curing procedures — performance, knowledge level and safety awareness among dentists10.1016/j.jdent.2017.02.002 ↗
5. The dark art of light measurement: accurate radiometry for low-level light therapy10.1007/s10103-016-1914-y ↗
6. Light-curing units: a review of what we need to know10.1177/0022034515594786 ↗
7. Comparing laboratory practice with clinical realities of dental light curing
8. A consensus-based approach to evidence-based clinical practice10.1016/j.dental.2017.08.184 ↗
9. End of the road for the randomized controlled trial in restorative dentistry?10.12968/denu.2017.44.9.806 ↗
10. The effectiveness of using a patient simulator to teach light-curing skills10.14219/jada.2013.17 ↗
11. Effect of instruction, light curing unit, and location in the mouth on the energy delivered to simulated restorations
12. Study of energy transfer by different light curing units into a class III restoration as a function of tilt angle and distance, using a MARC Patient Simulator (PS)10.1016/j.dental.2016.02.007 ↗
13. Properties of posterior composite: results of round robin testing for a specification10.1016/0109-5641(94)90047-7 ↗
14. Relevance of in-vitro tests of adhesive and composite dental materials. A review in 3 parts. Part 2: non-standardized tests of composite materials
15. Enhancing the Value of dental biomaterials research: “Reducing the Noise”10.1177/0022034518758245 ↗
16. ADM research guidance papers10.1016/j.dental.2017.06.006 ↗
17. Hecht · 2002
18. Ocean Optics Modular Spectrometers. https://oceanoptics.com/product-category/modular-spectrometers. [Accessed 1 November 2018].
19. Pembroke Instruments. https://pembrokeinstruments.com. [Accessed 1 November 2018].
20. Gigahertz-Optik. http://www.gigahertz-optik.de. [Accessed 1 November 2018].
21. BlueLight Analytics. https://www.bluelightanalytics.com. [Accessed 1 November 2018].
22. Curing dental resins and composites by photopolymerization10.1111/j.1708-8240.2000.tb00239.x ↗
23. Molar extinction coefficients and the photon absorption efficiency of dental photoinitiators and light curing units10.1016/j.jdent.2004.11.013 ↗
24. Ivocerin in comparison to camphorquinone
25. Robust spectrometer-based methods for characterizing radiant exitance of dental LED light curing units10.1016/j.dental.2015.02.012 ↗
26. Characterizing the output settings of dental curing lights10.1016/j.jdent.2015.10.019 ↗
27. Performance of two blue light-emitting-diode dental light curing units with distance and irradiation-time10.1016/S0109-5641(03)00070-8 ↗
28. Effect of distance on irradiance and beam homogeneity from 4 light-emitting diode curing units
29. Correlation between the beam profile from a curing light and the microhardness of four resins10.1016/j.dental.2014.10.001 ↗
30. Influence of emission spectrum and irradiance on light curing of resin-based composites10.2341/16-349-L ↗
31. Light-emitting diode beam profile and spectral output influence on the degree of conversion of bulk fill composites10.2341/16-164-L ↗
32. Degree of conversion and cross-link density within a resin-matrix composite10.1002/jbm.b.33960 ↗
33. Ability of four dental radiometers to measure the light output from nine curing lights10.1016/j.jdent.2016.08.010 ↗
34. Intra- and inter-brand accuracy of four dental radiometers10.1007/s00784-011-0562-7 ↗
35. Accuracy of LED and halogen radiometers using different light sources10.1111/j.1708-8240.2006.00023.x ↗