journal article·2012-03

Resin-composite cytotoxicity varies with shade and irradiance

Bernd W. Sigusch, Torsten Pflaum, Andrea Völpel, Kerstin Gretsch, Sandra Hoy, David C. Watts, Klaus D. Jandt

Dental Materials· Volume 28· Issue 3
Publisher page

Abstract

Objectives The study was aimed at investigating the cytotoxicity of different composites as a function of composite shade and the light curing unit (LCU) employed. Methods Non-polymerized and polymerized samples of the composites Grandio(®) (VOCO, Cuxhaven), Solitaire(®) (Heraeus Kulzer, Hanau) and Filtek Z 250(®) (3M/Espe, Seefeld) in two markedly differing shades (A2, C2) were prepared. Polymerization was performed with two LCUs: Heliolux II (Ivoclar/Vivadent, Ellwangen) and Swiss Master Light (EMS, Nyon, Switzerland). To obtain composite extracts, the samples were immersed in cell culture medium (DMEM--Dulbecco's Modified Eagle Medium), which was replaced daily up to the 7th day of the experiment, and then on the 14th, 21st and 28th day. After incubation of human gingival fibroblasts (HGF) with the extracts obtained, cytotoxicity was determined using the MTT test. Results With the non-polymerized samples, essentially no influence of the composite shades investigated on HGF viability was detected, with the exception of the Solitaire material, where a higher cytotoxicity of the shade C2 in the non-polymerized state was found at the end of the observation period. After polymerization of the different composites, the cytotoxic reaction observed for the extracts of shade C2 was stronger than that observed for A2. After polymerization with the Heliolux II (HLX) LCU, the extracts of composites Grandio and Solitaire C2 were significantly more toxic than those of the A2 shade (p<0.01). Polymerization with the Swiss Master Light (SML) reduces this cytotoxic effect. The extracts of the Grandio composite showed the least cytotoxic effect throughout the observation period, irrespective of the LCU used. For the extracts of the Z250 specimens, the cytotoxicity observed was generally higher. Significance The results show that the shade of the composite has an influence on its cytotoxicity and that this cytotoxicity is also influenced by the light curing unit used. It was observed that composites of the darker shade (C2) had a higher cytotoxicity, which varied with the LCU employed.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Laser Applications in Dentistry and Medicine · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (59)

Show source-provided references
1. Substances released from dental resin composites and glass ionomer cements10.1046/j.0909-8836.1998.eos10602ii04.x ↗
2. An in vitro pulp chamber with three dimensional cell cultures10.1016/S0099-2399(99)80394-X ↗
3. Cytotoxicity of composite materials polymerized with LED curing units10.2341/07-16 ↗
4. Molecular toxicology of substances released from resin-based dental restorative materials10.3390/ijms10093861 ↗
5. Cytotoxicity of four categories of dental cements10.1016/j.dental.2008.08.002 ↗
6. Future perspectives of resin-based dental materials10.1016/j.dental.2009.02.009 ↗
7. Cytotoxicity of dental composites and their leached components
8. In vitro and in vivo studies on the toxicity of dental resin components: a review10.1007/s00784-007-0162-8 ↗
9. Influence of different light curing units on the cytotoxicity of various dental composites10.1016/j.dental.2006.11.013 ↗
10. The influence of various light curing units on the cytotoxicity of dental adhesives10.1016/j.dental.2009.06.016 ↗
11. Raman scattering determination of the depth of cure of light-activated composites: influence of different clinically relevant parameters10.1046/j.1365-2842.2002.00889.x ↗
12. The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite10.1016/j.dental.2004.07.020 ↗
13. Resin composite properties and energy density of light cure10.1177/154405910508400715 ↗
14. Influence of the distance of the curing light source and composite shade on hardness of two composites10.1590/S1678-77572007000600006 ↗
15. Influence of light energy density on effectiveness of composite cure
16. Elution of leachable components from resin composites after plasma arc vs. standard or soft-start halogen light irradiation10.1016/S0300-5712(02)00022-2 ↗
17. Curing kinetics of a photo-polymerized dental sealant
18. Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure10.1007/s00784-005-0312-9 ↗
19. Franz · Dent Mater · 2007 · 23 · 143810.1016/j.dental.2007.05.014 ↗
20. Franz · Dent Mater · 2003 · 19 · 38210.1016/S0109-5641(02)00081-7 ↗
21. Composite resin microhardness: the influence of light curing method, composite shade, and depth of cure10.5005/jcdp-9-4-43 ↗
22. The effect of resin shades on microhardness, polymerization shrinkage, and color change of dental composite resins10.4012/dmj.28.438 ↗
23. Influence of pulse-delay curing on softening of polymer structures10.1177/00220345010800061801 ↗
24. Cytotoxic effects of dental bonding substances as a function of degree of conversion10.1016/j.dental.2008.07.003 ↗
25. The effect of light curing source on the residual yellowing of resin composites10.2341/06-129 ↗
26. Photoinitiation chemistry affects light transmission and degree of conversion of curing experimental dental resin composites10.1016/j.dental.2006.06.016 ↗
27. Development of a new photoinitiation system for dental light-cure composite resins10.1016/S0109-5641(99)00021-4 ↗
28. Photoinitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units10.1016/S0142-9612(02)00532-X ↗
29. Light energy transmission through composite influence by material shades10.2209/tdcpublication.50.183 ↗
30. ISO, Standard 10993. Biological evaluations of medical devices. Part 12. Sample preparation and reference materials 1996; 12.
31. Long-term cytotoxicity of resin-based dental restorative materials10.1046/j.1365-2842.2002.00804.x ↗
32. Cytotoxicity of composites resins polymerized with different curing methods10.1111/j.0143-2885.2004.00779.x ↗
33. In vitro cytotoxicity of a composite resin and compomer10.1046/j.1365-2591.2002.00456.x ↗
34. In vitro biological response to core and flowable dental restorative materials10.1016/S0109-5641(02)00012-X ↗
35. Resin composite monomers alter MTT and LDH activity of human gingival fibroblasts in vitro10.1016/S0109-5641(03)00053-8 ↗
36. Cytotoxicity tests of in situ polymerized resin: methodological comparisons and introduction of a tissue culture insert as a testing device10.1002/(SICI)1097-4636(19990605)45:3<214::AID-JBM9>3.0.CO;2-Y ↗
37. Shrinkage behavior of a resin-based composite irradiated with modern curing units
38. Monomer release from resin based dental materials cured with LED and halogen lights10.1055/s-0039-1697806 ↗
39. Effect of co-initiator ratio on the polymer properties of experimental resin composites formulated with camphorquinone and phenyl-propanedione10.1016/j.dental.2008.08.003 ↗
40. Photopolymerization of N,N-dimethylaminobenzyl alcohol as amine co-initiator for light-cured dental resins10.1016/j.dental.2007.06.035 ↗
41. Relationships between conversion, temperature and optical properties during composite photopolymerization
42. Influence of photoinitiator type on the rate of polymerization, degree of conversion, hardness and yellowing of dental resin composites10.1016/j.dental.2008.01.007 ↗
43. Influence of resin-based restoration materials on cytotoxicity in gingival fibroblasts
44. Cytotoxic and mutagenic effects of dental composite materials10.1016/j.biomaterials.2004.05.025 ↗
45. In vitro cytotoxicity of resin-containing restorative materials after aging in artificial saliva10.1007/s007840050093 ↗
46. Comparison of curing depth of a colored polyacid-modified composite resin with different light curing units
47. Effect of light curing tip distance and resin shade on microhardness of a hybrid resin composite10.1590/S1806-83242005000400012 ↗
48. Curing depth of different shades of a photoactivated prosthetic composite material10.1046/j.1365-2842.2001.00697.x ↗
49. Influence of heat from light curing units and dental composite polymerization on cells in vitro10.1016/j.jdent.2005.07.004 ↗
50. Personal statement by VOCO about the chemical composition of Grandio.
51. Photoinitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units10.1016/S0142-9612(02)00532-X ↗
52. Influence of pulse-delay curing on softening of polymer structures10.1177/00220345010800061801 ↗
53. Effects of various light curing methods on the leachability of uncured substances and hardness of a composite resin10.1111/j.1365-2842.2004.01172.x ↗
54. The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite10.1016/j.dental.2004.07.020 ↗
55. Resin composite properties and energy density of light cure10.1177/154405910508400715 ↗
56. Light curing of resin-based composites in the LED era
57. Temperature excursions at the pulp–dentin junction during the curing of light-activated dental restorations10.1016/j.dental.2008.03.012 ↗
58. Thermal variations in the pulp chamber associated with composite insertion techniques and light-curing methods10.5005/jcdp-10-1-17 ↗
59. Pulp chamber temperature rise during curing of resin-based composites with different light-curing unit10.1177/2050168408os1500101 ↗