The presented article discusses recent advances in biomedical applications of classical magnetohydrodynamics (MHD), with a focus on operating principles and associated material considerations. These applications address novel approaches to common biomedical problems from microparticle sorting for lab‐on‐a‐chip devices to advanced physiological monitoring techniques. 100 papers in the field of MHDs are reviewed with a focus on studies with direct biomedical applications. The body of literature is categorized into three primary areas of research including material considerations for MHD applications, MHD actuation devices, and MHD sensing techniques. The state of the art in the field is examined and research topics are connected to provide a wide view of the field of biomedical MHDs. As this field develops, the need for advanced simulation and material design will continue to increase in importance in order to further expand its reach to maturity. As the field of biomedical MHDs continues to grow, advances toward microscale transitions will continue to be made, maintaining its clinically driven nature and moving toward real‐world applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrohydrodynamics and Fluid Dynamics · Electrospun Nanofibers in Biomedical Applications · Characterization and Applications of Magnetic Nanoparticles
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Engineering The University of Georgia 597 D.W. Brooks Drive Athens GA 30602 USA
Advanced Materials Institute Graduate School at Shenzhen Tsinghua University Shenzhen 518055 P.R. China
Funding
National Science Foundation
References (100+)
Show source-provided references
1. Priest E. R. · 2003
2. 10.1007/978-1-4757-0836-310.1007/978-1-4757-0836-3 ↗
3. D. R.Laughlin “A magnetohydrodynamic angular motion sensor for anthropomorphic test device instrumentation ” SAE Technical Paper 1989.10.4271/892428 ↗
4. 10.1016/S0924-4247(99)00302-710.1016/S0924-4247(99)00302-7 ↗
5. 10.1016/S0925-4005(00)00355-510.1016/S0925-4005(00)00355-5 ↗
6. 10.1063/1.171120710.1063/1.1711207 ↗
7. 10.1063/1.172442610.1063/1.1724426 ↗
8. Blandford R. · 2004
9. 10.1182/blood.V5.11.1017.101710.1182/blood.V5.11.1017.1017 ↗
10. 10.1016/S0925-4005(02)00325-810.1016/S0925-4005(02)00325-8 ↗
11. 10.1016/j.mechrescom.2008.06.01310.1016/j.mechrescom.2008.06.013 ↗
12. 10.1007/s10404-010-0668-210.1007/s10404-010-0668-2 ↗
13. 10.1103/PhysRevE.68.01631210.1103/PhysRevE.68.016312 ↗
14. 10.1016/j.ijheatmasstransfer.2004.12.01910.1016/j.ijheatmasstransfer.2004.12.019 ↗
15. 10.1007/s10404-011-0903-510.1007/s10404-011-0903-5 ↗
16. 10.1017/CBO978051162633310.1017/CBO9780511626333 ↗
17. 10.1017/S002211208100298X10.1017/S002211208100298X ↗
18. 10.1016/j.bios.2003.10.01810.1016/j.bios.2003.10.018 ↗
19. 10.1109/EMB.2007.91026010.1109/EMB.2007.910260 ↗
20. 10.1109/TMECH.2006.87189710.1109/TMECH.2006.871897 ↗
21. 10.1002/jmri.1019610.1002/jmri.10196 ↗
22. 10.1002/rcs.1910.1002/rcs.19 ↗
23. 10.1109/ROBOT.2006.164228710.1109/ROBOT.2006.1642287 ↗
24. C. D.Wahlstrand T. B.Hoegh G. A.Hrdlicka T. E.CrossJr. J. M.Olsen US. Patent No.7 174 219 2007.
25. 10.1002/mrm.2474410.1002/mrm.24744 ↗
26. Williams D. F. · 1987
27. Ratner B. D. · 2004
28. Breme J. · 1988 · 57
29. 10.1016/S0142-9612(97)00146-410.1016/S0142-9612(97)00146-4 ↗
30. 10.1016/S0043-1648(03)00557-X10.1016/S0043-1648(03)00557-X ↗
31. 10.1002/jbm.121210.1002/jbm.1212 ↗
32. 10.1016/S0142-9612(98)00217-810.1016/S0142-9612(98)00217-8 ↗
33. 10.1016/S0921-5093(97)00806-X10.1016/S0921-5093(97)00806-X ↗
34. 10.1016/0142-9612(92)90018-J10.1016/0142-9612(92)90018-J ↗
35. 10.1039/b206756k10.1039/b206756k ↗
36. 10.1016/j.sna.2006.06.01410.1016/j.sna.2006.06.014 ↗
37. 10.1016/S0925-4005(04)00108-X10.1016/S0925-4005(04)00108-X ↗
38. 10.1039/b417892k10.1039/b417892k ↗
39. 10.1007/s10404-007-0255-310.1007/s10404-007-0255-3 ↗
40. 10.1063/1.193313110.1063/1.1933131 ↗
41. 10.1088/0960-1317/15/2/R0110.1088/0960-1317/15/2/R01 ↗
42. 10.3390/ijms1205326310.3390/ijms12053263 ↗
43. 10.1007/128_2011_15010.1007/128_2011_150 ↗
44. 10.1016/S0925-4005(01)00851-610.1016/S0925-4005(01)00851-6 ↗
45. 10.1017/S002211200200163510.1017/S0022112002001635 ↗
46. 10.1016/j.snb.2010.03.07710.1016/j.snb.2010.03.077 ↗
47. 10.1016/j.snb.2004.07.01110.1016/j.snb.2004.07.011 ↗
48. 10.1023/A:102441540063310.1023/A:1024415400633 ↗
49. 10.1109/MMB.2005.154844710.1109/MMB.2005.1548447 ↗
50. 10.1109/TMECH.2015.241251710.1109/TMECH.2015.2412517 ↗
51. 10.1146/annurev.matsci.31.1.8110.1146/annurev.matsci.31.1.81 ↗
52. Wallin R. · Med. Device Diagn. Ind. · 1998 · 20 · 96
53. S.Speakman U.S. Patent No.6 164 850 2000.
54. 10.1021/ac403397r10.1021/ac403397r ↗
55. Burke M. · 2013
56. 10.1109/ROBOT.2008.454365310.1109/ROBOT.2008.4543653 ↗
57. 10.1109/TMECH.2010.204124410.1109/TMECH.2010.2041244 ↗
58. 10.1063/1.136253210.1063/1.1362532 ↗
59. D. R.Laughlin U.S. Patent No.5 665 912 1997.
60. A. P.Lee A. V.Lemoff U.S. Patent No.6 146 103 2000.
61. 10.1186/1532-429X-17-S1-P3210.1186/1532-429X-17-S1-P32 ↗
62. Lurie K. · 2013
63. D. R.Laughlin U.S. Patent No.5 067 3511991.
64. 10.22364/mhd.45.3.1910.22364/mhd.45.3.19 ↗
65. 10.1049/PBRA017E10.1049/PBRA017E ↗
66. Eckelkamp‐Baker D. · 2000 · 96
67. 10.1016/0017-9310(82)90036-910.1016/0017-9310(82)90036-9 ↗
68. 10.1007/978-1-4020-4833-3_1710.1007/978-1-4020-4833-3_17 ↗
69. 10.1109/20.70682310.1109/20.706823 ↗
70. 10.13182/FST86-A2483910.13182/FST86-A24839 ↗
71. Abi‐Abdallah D. · 2007 · 1842
72. 10.1002/bem.225004010210.1002/bem.2250040102 ↗
73. Tenforde T. S. · 1985 · 66
74. 10.1109/TBME.2008.91986810.1109/TBME.2008.919868 ↗
75. 10.1051/epjap:200819310.1051/epjap:2008193 ↗
76. Bhatt B. · Ind. J. Biomech. · 2009 · 51
77. Nijm G. · 2006
78. 10.1007/s11517-008-0307-110.1007/s11517-008-0307-1 ↗
79. 10.1080/10255842.2014.90909010.1080/10255842.2014.909090 ↗
80. 10.1002/mrm.2545610.1002/mrm.25456 ↗
81. 10.1007/s10439-014-1109-210.1007/s10439-014-1109-2 ↗
82. 10.1161/01.cir.0000451596.4581810.1161/01.cir.0000451596.45818 ↗
83. 10.1002/mrm.2507810.1002/mrm.25078 ↗
84. 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO;2-910.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO;2-9 ↗
85. Frauenrath T. · Proc. Int. Soc. Mag. Reson. Med. · 2011 · 19
86. 10.1002/jmri.2363410.1002/jmri.23634 ↗
87. 10.1016/0142-9612(81)90059-410.1016/0142-9612(81)90059-4 ↗
88. 10.1016/j.progpolymsci.2007.05.01710.1016/j.progpolymsci.2007.05.017 ↗
89. 10.1016/j.ab.2007.01.00310.1016/j.ab.2007.01.003 ↗
90. 10.1016/S0142-9612(99)00231-810.1016/S0142-9612(99)00231-8 ↗
91. 10.1016/j.biomaterials.2007.07.03510.1016/j.biomaterials.2007.07.035 ↗
92. 10.1097/00002480-198804000-0000410.1097/00002480-198804000-00004 ↗
93. 10.1016/j.biomaterials.2005.07.03510.1016/j.biomaterials.2005.07.035 ↗
94. 10.1016/j.carbpol.2008.07.03210.1016/j.carbpol.2008.07.032 ↗
95. 10.1016/0039-6257(82)90161-810.1016/0039-6257(82)90161-8 ↗
96. 10.1016/S0142-9612(00)00344-610.1016/S0142-9612(00)00344-6 ↗
97. 10.1016/0142-9612(80)90035-610.1016/0142-9612(80)90035-6 ↗
98. 10.1016/j.biomaterials.2006.08.01410.1016/j.biomaterials.2006.08.014 ↗
99. 10.1016/j.biomaterials.2005.10.00310.1016/j.biomaterials.2005.10.003 ↗
100. 10.1016/j.cossms.2009.04.00110.1016/j.cossms.2009.04.001 ↗