Here we present the development and characterization of a flexible implantable neural probe with glassy carbon electrode arrays. The use of carbon electrodes allows for these devices to be used as chemical sensors, in addition to their typical use as electrical sensors and stimulators. The devices are fabricated out of polyimide, platinum, titanium, and carbon with standard microfabrication techniques on carrier wafers. The devices are released from the substrate through either chemical or electrochemical dissolution of the underlying substrate material. The glassy carbon electrode arrays are produced through the pyrolysis of SU‐8 pillars at 900 °C as the first process step, as this temperature is incompatible with the other device materials. The process demonstrated here is generally applicable, allowing for the integration of various high temperature materials into flexible devices.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · EEG and Brain-Computer Interfaces
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Microsystems Laboratory, EPFL‐STI‐IMT‐LMIS4 École Polytechnique Fédérale de Lausanne (EPFL) 1015 Lausanne Switzerland
Aleva Neurotherapeutics SA EPFL Innovation Park D 1015 Lausanne Switzerland
References (47)
Show source-provided references
1. 10.1109/TBME.2009.201845710.1109/TBME.2009.2018457 ↗
2. 10.1146/annurev.bioeng.10.061807.16051810.1146/annurev.bioeng.10.061807.160518 ↗
3. 10.1038/nature0497010.1038/nature04970 ↗
4. 10.1016/S0042-6989(03)00457-710.1016/S0042-6989(03)00457-7 ↗
5. 10.1121/1.138153810.1121/1.1381538 ↗
6. 10.1126/science.121741610.1126/science.1217416 ↗
7. 10.1007/s00422000021810.1007/s004220000218 ↗
8. 10.1111/j.1085-9489.2005.10303.x10.1111/j.1085-9489.2005.10303.x ↗
9. 10.1093/brain/awu10210.1093/brain/awu102 ↗
10. Mercanzini A. · 2007 · 573
11. Suzuki T. · 2003 · 154
12. 10.1002/adfm.20120371610.1002/adfm.201203716 ↗
13. 10.1016/j.jconrel.2010.04.02510.1016/j.jconrel.2010.04.025 ↗
14. 10.1109/TBME.2008.91912610.1109/TBME.2008.919126 ↗
15. 10.1016/j.jneumeth.2008.06.03610.1016/j.jneumeth.2008.06.036 ↗
16. 10.1016/0039-9140(94)E0064-X10.1016/0039-9140(94)E0064-X ↗
17. 10.1016/S0165-9936(03)00907-510.1016/S0165-9936(03)00907-5 ↗
18. 10.1373/49.10.176310.1373/49.10.1763 ↗
19. 10.1103/PhysRevB.18.218510.1103/PhysRevB.18.2185 ↗
20. 10.1103/PhysRevLett.53.204210.1103/PhysRevLett.53.2042 ↗
21. 10.1021/ac900790m10.1021/ac900790m ↗
22. 10.1007/978-1-4419-1543-6_510.1007/978-1-4419-1543-6_5 ↗
23. 10.1002/elps.20110005910.1002/elps.201100059 ↗
24. 10.1016/j.sna.2007.07.02710.1016/j.sna.2007.07.027 ↗
25. 10.1109/JMEMS.2004.83932810.1109/JMEMS.2004.839328 ↗
26. 10.1136/bjo.2005.08911010.1136/bjo.2005.089110 ↗
27. 10.1002/978352762317410.1002/9783527623174 ↗
28. 10.1016/S0022-0728(99)00197-710.1016/S0022-0728(99)00197-7 ↗
29. Paproth A. · 2006 · 959
30. 10.1021/la991350610.1021/la9913506 ↗
31. Martinsen O. G. · 2008
32. 10.1016/S0040-6090(03)00318-310.1016/S0040-6090(03)00318-3 ↗
33. 10.1109/JMEMS.2003.82093610.1109/JMEMS.2003.820936 ↗
34. 10.1149/1.240786510.1149/1.2407865 ↗
35. 10.1016/S0022-0728(72)80122-010.1016/S0022-0728(72)80122-0 ↗
36. 10.1023/A:101849301644410.1023/A:1018493016444 ↗
37. 10.1016/j.sna.2003.11.03610.1016/j.sna.2003.11.036 ↗
38. Rahim R. A. · 2012 · 204
39. 10.1016/0956-5663(95)96795-Z10.1016/0956-5663(95)96795-Z ↗
40. 10.1039/c3an00791j10.1039/c3an00791j ↗
41. 10.1007/BF0244705910.1007/BF02447059 ↗
42. 10.1016/S1452-3981(23)15482-410.1016/S1452-3981(23)15482-4 ↗
43. 10.1016/0013-4686(94)E0166-W10.1016/0013-4686(94)E0166-W ↗
44. 10.1149/1.205934310.1149/1.2059343 ↗
45. 10.1038/nmeth.141210.1038/nmeth.1412 ↗
46. 10.1186/1743-0003-8-4410.1186/1743-0003-8-44 ↗
47. 10.1016/S0165-0270(01)00514-310.1016/S0165-0270(01)00514-3 ↗