journal article·2017-11

Scaling Effects on the Electrochemical Performance of poly(3,4‐ethylenedioxythiophene (PEDOT), Au, and Pt for Electrocorticography Recording

Mehran Ganji, Ahmed T. Elthakeb, Atsunori Tanaka, Vikash Gilja, Eric Halgren, Shadi A. Dayeh

Advanced Functional Materials· Volume 27· Issue 42
Publisher page

Abstract

Abstract Reduced contact size would permit higher resolution cortical recordings, but the effects of diameter on crucial recording and stimulation properties are poorly understood. Here, the first systematic study of scaling effects on the electrochemical properties of metallic Pt and Au and organic poly(3,4‐ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) electrodes is presented. PEDOT:PSS exhibits better faradaic charge transfer and capacitive charge coupling than metal electrodes, and these characteristics lead to improved electrochemical performance and reduced noise at smaller electrode diameters. PEDOT:PSS coating reduces the impedances of metallic electrodes by up to 18x for diameters <200 µm, but has no effect for millimeter scale contacts due to the dominance of series resistances. Therefore, the performance gains are especially significant at smaller diameters and lower frequencies essential for recording cognitive and pathological activities. Additionally, the overall reduced noise of the PEDOT:PSS electrodes enables a lower noise floor for recording action potentials. These results permit quantitative optimization of contact material and diameter for different electrocorticography applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Computer Engineering University of California San Diego La Jolla CA 92093 USA

Materials Science and Engineering Program University of California San Diego La Jolla CA 92093 USA

Neurosciences Program University of California San Diego La Jolla CA 92096 USA

Departments of Radiology and Neuroscience University of California San Diego La Jolla CA 92103 USA

Department of NanoEngineering University of California San Diego La Jolla CA 92093 USA

Funding

Office of Naval Research

References (20)

Show source-provided references
1. 10.1523/JNEUROSCI.3879-08.200810.1523/JNEUROSCI.3879-08.2008 ↗
2. 10.1038/nn123310.1038/nn1233 ↗
3. 10.1146/annurev.bioeng.10.061807.16051810.1146/annurev.bioeng.10.061807.160518 ↗
4. 10.1109/TBME.2005.84752310.1109/TBME.2005.847523 ↗
5. 10.1146/annurev.neuro.051508.13524110.1146/annurev.neuro.051508.135241 ↗
6. 10.1109/10.4360510.1109/10.43605 ↗
7. 10.1088/1741-2560/8/1/01400110.1088/1741-2560/8/1/014001 ↗
8. 10.1002/adma.20120432210.1002/adma.201204322 ↗
9. 10.1002/adma.20110237810.1002/adma.201102378 ↗
10. 10.1038/nn.390510.1038/nn.3905 ↗
11. 10.1126/sciadv.160102710.1126/sciadv.1601027 ↗
12. Hermiz J. · 2016 · 4511
13. 10.1002/adhm.20160087010.1002/adhm.201600870 ↗
14. 10.1038/ncomms1128710.1038/ncomms11287 ↗
15. 10.1016/j.neuron.2014.12.03510.1016/j.neuron.2014.12.035 ↗
16. 10.1038/nrn324110.1038/nrn3241 ↗
17. Yuan X.‐Z. R. · 2009
18. Ganji M. · Adv. Funct. Mater. · 2017 · 27 · 1700323
19. 10.1016/0375-9601(70)90713-910.1016/0375-9601(70)90713-9 ↗
20. 10.1016/0301-4622(78)87007-010.1016/0301-4622(78)87007-0 ↗