journal article·2014-04

In vitro monitoring of goat-blood glycemia with a microwave biosensor

Seungwan Kim, Jongchel Kim, Kyoungchul Kim, Jung-Ha Lee, Arsen Babajanyan, Barry Friedman, Kiejin Lee

Current Applied Physics· Volume 14· Issue 4
Publisher page

Abstract

Abstract We used an electromagnetic microwave cavity sensor for real time measurement of the glycemia in goat-blood for three animals. We could determine the concentration of d -glucose in blood in the range of 90–550 mg/dl at the resonance frequency near 4.76 GHz with a bandwidth of 300 MHz. The change in microwave reflection coefficient S 11 (due to the variation of d -glucose concentration in blood) was about 16.33 dB, 23.92 dB, 7.66 dB and resonance frequency shift was about 21.78 MHz, 36.29 MHz, 20.77 MHz, respectively, for the three different samples. The in vitro results show the measured signal-to-noise ratio of about 32 dB, and the minimum detectable signal level of about 0.025 dB/(mg/dl). The results clearly show the sensitivity and usefulness of this microwave sensor for these types of biological investigations. This proposed system provides a unique approach for real contactless glucose monitoring and, it may serve as a bloodless glucometer for the calibration of different glucose levels.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spectroscopy Techniques in Biomedical and Chemical Research · Microwave and Dielectric Measurement Techniques · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. IDF · 2010
2. Goldstein · Endocr. Metab. Clin. North Am. · 1997 · 26 · 47510.1016/S0889-8529(05)70261-9 ↗
3. Khalil · Clin. Chem. · 1999 · 45 · 16510.1093/clinchem/45.2.165 ↗
4. Khalil · Diabetes Technol. Ther. · 2004 · 6 · 66010.1089/dia.2004.6.660 ↗
5. Wilson · Biosens. Bioelectron. · 2005 · 20 · 238810.1016/j.bios.2004.12.003 ↗
6. 2006
7. Musil · Nutrition · 2008 · 24 · 61410.1016/j.nut.2008.02.017 ↗
8. Newman · Biosens. Bioelectron. · 2005 · 20 · 243510.1016/j.bios.2004.11.012 ↗
9. Tura · Diabetes Res. Clin. Pract. · 2007 · 77 · 1610.1016/j.diabres.2006.10.027 ↗
10. Ibbini · J. Med. Eng. Technol. · 2005 · 29 · 6410.1080/03091900410001709088 ↗
11. Tura · Sensors · 2010 · 10 · 534610.3390/s100605346 ↗
12. Rouane · Sens. Trans. J. · 2008 · 93 · 69
13. Hayashi · Med. Eng. Phys. · 2012 · 34 · 29910.1016/j.medengphy.2011.07.020 ↗
14. Caduff · Biosens. Bioelectron. · 2009 · 24 · 277810.1016/j.bios.2009.02.001 ↗
15. McNichols · J. Biomed. Opt. · 2000 · 5 · 510.1117/1.429962 ↗
16. Koschinsky · Diabetes Metab. Res. Rev. · 2001 · 17 · 11310.1002/dmrr.188 ↗
17. Schwan · IEEE Trans. Microwave Theory Tech. · 1968 · 19 · 14610.1109/TMTT.1968.1127476 ↗
18. Hagness · Electron. Lett. · 1997 · 33 · 159410.1049/el:19971106 ↗
19. Kim · Rev. Sci. Instrum. · 2008 · 79 · 08610710.1063/1.2968115 ↗
20. Melikyan · Med. Eng. Phys. · 2012 · 34 · 29910.1016/j.medengphy.2011.07.020 ↗
21. Kim · Diabetes Res. Clin. Pract. · 2012 · 96 · 37910.1016/j.diabres.2012.01.018 ↗
22. Pozar · 2005
23. Silva · Supercond. Sci. Technol. · 1996 · 9 · 93410.1088/0953-2048/9/11/003 ↗
24. Lide · 2004
25. Hillier · Am. J. Med. · 1999 · 106 · 39910.1016/S0002-9343(99)00055-8 ↗
26. Haller · Diabetes Technol. Ther. · 2007 · 9 · 110.1089/dia.2006.0051 ↗