Synovial Fluid pH Sensor for Early Detection of Prosthetic Hip Infections
Source abstract
Abstract
Abstract An implantable sensor developed to measure synovial fluid pH for noninvasive early detection and monitoring of hip infections using standard‐of‐care plain radiography is described. The sensor is made of a pH responsive polyacrylic acid‐based hydrogel, which expands at high pH and contracts at low pH. A radiodense tantalum bead and a tungsten wire are embedded in the two ends of the hydrogel to monitor the change in length of the hydrogel sensor in response to pH via plain radiography. The effective acid dissociation constant (pKa) of the hydrogel‐based pH sensor is 5.6 with a sensitivity of 3 mm/pH unit between pH 4 and 8. The sensor shows a linear response and reversibility in the physiologically relevant pH range of pH 6.5 and 7.5 in both buffer and bovine synovial fluid solutions with a 30‐minute time constant. The sensor is attached to an explanted prosthetic hip, and the pH response is determined from the X‐ray images by measuring the length between the tantalum bead and the radiopaque wire. Therefore, the developed sensor will enable noninvasive detection and studying of implant hip infection using plain radiography.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopedic Infections and Treatments · Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Chemistry Clemson University 102 BRC, 105 Collings St. Clemson SC 29634 USA
Department of Orthopedic Surgery Prisma Health‐Upstate Second Floor Support Tower, 701 Grove Road Greenville SC 29605 USA
OrthoArizona 1675 E. Melrose St. Gilbert AZ 85297 USA
Departments of Chemistry and BioEngineering, and Center for Optical Materials Science and Engineering Technology (COMSET) Clemson University 102 BRC, 105 Collings St. Clemson SC 29634 USA
References (64)
Show source-provided references
1. 10.1128/CMR.00111-1310.1128/CMR.00111-13 ↗
2. 10.7326/0003-4819-133-9-200011070-0001510.7326/0003-4819-133-9-200011070-00015 ↗
3. 10.1016/j.rdc.2006.12.00810.1016/j.rdc.2006.12.008 ↗
4. 10.1056/NEJMcp090502910.1056/NEJMcp0905029 ↗
5. 10.1007/s11999-008-0209-410.1007/s11999-008-0209-4 ↗
6. 10.1093/cid/cis96610.1093/cid/cis966 ↗
7. 10.4161/biom.2290510.4161/biom.22905 ↗
8. 10.1086/52943610.1086/529436 ↗
9. 10.1016/j.ijantimicag.2008.03.01010.1016/j.ijantimicag.2008.03.010 ↗
10. 10.1007/s11999-010-1298-410.1007/s11999-010-1298-4 ↗
11. 10.1302/0301-620X.90B7.2041710.1302/0301-620X.90B7.20417 ↗
12. 10.1097/00013542-200301000-0000110.1097/00013542-200301000-00001 ↗
13. Birlutiu V. · Biomed. Res. · 2017 · 28 · 11
14. 10.3109/00365548.2015.100667410.3109/00365548.2015.1006674 ↗
15. 10.1002/art.178014040710.1002/art.1780140407 ↗
16. 10.1177/205873841880607210.1177/2058738418806072 ↗
17. 10.1007/s11999-011-1991-y10.1007/s11999-011-1991-y ↗
18. 10.1016/j.arth.2014.01.01410.1016/j.arth.2014.01.014 ↗
19. 10.1302/2058-5241.1.16001910.1302/2058-5241.1.160019 ↗
20. 10.1016/0002-9343(78)90446-110.1016/0002-9343(78)90446-1 ↗
21. 10.1007/s00011-013-0591-610.1007/s00011-013-0591-6 ↗
22. 10.1002/art.178021070610.1002/art.1780210706 ↗
23. 10.2106/JBJS.G.0125510.2106/JBJS.G.01255 ↗
24. 10.1002/adhm.20130010110.1002/adhm.201300101 ↗
25. 10.1177/23094990130210022510.1177/230949901302100225 ↗
26. 10.1016/j.jemermed.2005.05.02910.1016/j.jemermed.2005.05.029 ↗
27. 10.1016/j.diii.2012.03.00410.1016/j.diii.2012.03.004 ↗
28. 10.3390/diagnostics304035610.3390/diagnostics3040356 ↗
29. 10.1016/j.jare.2013.07.00610.1016/j.jare.2013.07.006 ↗
30. 10.1016/j.eurpolymj.2014.11.02410.1016/j.eurpolymj.2014.11.024 ↗
31. 10.1039/c2cp41858d10.1039/c2cp41858d ↗
32. 10.1021/acssensors.9b0096210.1021/acssensors.9b00962 ↗
33. D.Cristea I.Ghiuță D.Munteanu 2015 8 8.
34. 10.1088/1741-2552/aaa50210.1088/1741-2552/aaa502 ↗
35. 10.3390/ma1008088410.3390/ma10080884 ↗
36. 10.1016/j.polymer.2003.12.04010.1016/j.polymer.2003.12.040 ↗
37. 10.1002/bip.2241210.1002/bip.22412 ↗
38. 10.1021/ma970957v10.1021/ma970957v ↗
39. 10.1021/ma951006p10.1021/ma951006p ↗
40. 10.1063/1.491492410.1063/1.4914924 ↗
41. 10.1039/C8AN02337A10.1039/C8AN02337A ↗
42. 10.1038/s41598-017-01009-710.1038/s41598-017-01009-7 ↗
43. Carrington N. T. · medRxiv · 2020
44. Rajamanthrilage A. C. · IEEE TMBE · 2021
45. J.Anker C. J.Behrend J. D.DesJardins (Clemson University Research Foundation) US 10667745 B2 2020.
46. 10.1007/s10965-018-1672-610.1007/s10965-018-1672-6 ↗
47. 10.3144/expresspolymlett.2007.2610.3144/expresspolymlett.2007.26 ↗
48. 10.1002/anr.178032030810.1002/anr.1780320308 ↗
49. 10.4081/or.2013.e1410.4081/or.2013.e14 ↗
50. Cochran K. W. · Arch. Ind. Hyg. Occup. Med. · 1950 · 1 · 637
51. 10.1590/1516-1439.34871410.1590/1516-1439.348714 ↗
52. 10.3390/ma1203040710.3390/ma12030407 ↗
53. Burke G. L. · Can. Med. Assoc. J. · 1940 · 43 · 125
54. 10.1016/j.addr.2012.09.01010.1016/j.addr.2012.09.010 ↗
55. 10.1007/s00253-020-11073-110.1007/s00253-020-11073-1 ↗
56. 10.1007/BF0276356710.1007/BF02763567 ↗
57. 10.3390/ijms1009403310.3390/ijms10094033 ↗
58. 10.1016/j.polymdegradstab.2020.10930810.1016/j.polymdegradstab.2020.109308 ↗
59. 10.3390/chemosensors803006610.3390/chemosensors8030066 ↗
60. 10.1016/j.tvjl.2018.07.01110.1016/j.tvjl.2018.07.011 ↗
61. 10.1007/s10544-005-3026-510.1007/s10544-005-3026-5 ↗
62. 10.1016/j.snb.2005.12.02210.1016/j.snb.2005.12.022 ↗
63. 10.1002/adhm.20170080110.1002/adhm.201700801 ↗
64. 10.1021/ma981659g10.1021/ma981659g ↗