journal article·2013-06

Corrosion behaviour of porous Ti–39Nb alloy for biomedical applications

Jaroslav Fojt, Luděk Joska, Jaroslav Málek

Corrosion Science· Volume 71
Publisher page

Abstract

Abstract The presented work was aimed to describe the effect of porosity on the corrosion behaviour of Ti–39Nb alloy produced by the powder metallurgy technology, which represents a prospective material for medical applications. Corrosion properties of specimens with a porosity ranging from 0% to 33% were studied in simulated body environments, using electrochemical techniques and exposure tests. The results of measurements proved the occurrence of a localized form of corrosion in the material with a porosity of 24% and 33%. Distinct localization of the corrosion process was recorded in an environment containing fluoride ions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. M. Abdel-Hady Gepreel, M. Niinomi, Biocompatibility of Ti-alloys for long-term implantation, J. Mech. Behav. Biomed. Mater., 2012.10.1016/j.jmbbm.2012.11.014 ↗
2. Recent advances in the design of titanium alloys for orthopedic applications10.1586/17434440.2.6.741 ↗
3. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
4. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
5. Wolff’s Law and bone’s structural adaptations to mechanical usage: an overview for clinicians
6. Aseptic loosening of femoral components – materials engineering and design considerations10.1016/j.matdes.2012.07.066 ↗
7. Aseptic loosening of femoral components – a review of current and future trends in materials used10.1016/j.matdes.2012.05.046 ↗
8. Y. Bai, Y.L. Hao, S.J. Li, Y.Q. Hao, R. Yang, F. Prima, Corrosion behavior of biomedical Ti–24Nb–4Zr–8Sn alloy in different simulated body solutions, Mater. Sci. Eng.: C, 2013.10.1016/j.msec.2013.01.036 ↗
9. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids10.1016/j.corsci.2012.08.042 ↗
10. Electrochemical corrosion behavior of Ti–24Nb–4Zr–8Sn alloy in a simulated physiological environment10.1016/j.apsusc.2011.12.096 ↗
11. Comparative study on the corrosion behavior of Ti–Nb and TMA alloys for dental application in various artificial solutions10.1016/j.msec.2010.12.010 ↗
12. Corrosion behavior of β titanium alloys for biomedical applications10.1016/j.msec.2011.02.005 ↗
13. Corrosion behavior of Ti–Ta–Nb alloys in simulated physiological media10.1016/j.matlet.2007.10.028 ↗
14. The electrochemical behaviour of Ti–13Nb–13Zr alloy in various solutions10.1002/maco.200804148 ↗
15. Osteoinduction of porous bioactive titanium metal10.1016/S0142-9612(03)00551-9 ↗
16. Titanium scaffolds for osteointegration: mechanical, in vitro and corrosion behavior
17. 3D imaging of tissue integration with porous biomaterials10.1016/j.biomaterials.2008.06.018 ↗
18. Isochronal sintering of the blended elemental Ti–35Nb alloy
19. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
20. A comparison between the corrosion characteristics of 316 stainless steel, solid titanium, and porous titanium10.1016/0010-938X(93)90021-8 ↗
21. A comparison between the corrosion behavior of sintered and unsintered porous titanium10.1016/0010-938X(95)00033-G ↗
22. The influence of pore morphology on corrosion10.1016/S0010-938X(97)00152-2 ↗
23. Stability of protective oxide films formed on a porous titanium10.1016/S0010-938X(01)00080-4 ↗
24. Corrosion behavior of porous titanium-graphite composites designed for surgical implants10.1016/S0010-938X(99)00103-1 ↗
25. Structural characterization and electrochemical behavior of a laser-sintered porous Ti–10Mo alloy10.1016/j.corsci.2012.10.036 ↗
26. Temperature dependence of crevice corrosion initiation on titanium grade-210.1149/1.1499501 ↗
27. Crevice corrosion monitoring of titanium and its alloys using microelectrodes10.1002/maco.200604022 ↗
28. Crevice corrosion of titanium. Behaviour of galvanic cell between shielded and unshielded titanium in sulphuric acid10.1016/0010-938X(75)90014-1 ↗
29. Effects of fluorides on titanium and other dental alloys in dentistry10.1016/S0142-9612(97)00179-8 ↗
30. An electrochemical study of the crevice corrosion resistance of NiTi in Hanks’ solution10.1016/j.jallcom.2006.07.127 ↗
31. Surface treatment of NiTi shape memory alloy and its influence on corrosion behavior10.1016/j.surfcoat.2010.05.010 ↗
32. Effects of short-time heat treatment and subsequent chemical surface treatment on the mechanical properties, low-cycle fatigue behavior and corrosion resistance of a Ni–Ti (50.9at.% Ni) biomedical alloy wire used for the manufacture of stents10.1016/j.msea.2010.10.043 ↗
33. ASTM Standard F2129-08, 2008, Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices, ASTM International, West Conshohocken, PA, 2003, doi: 10.1520/F2129-08, www.astm.org.10.1520/F2129-08 ↗
34. CRC Handbook of Chemistry and Physics, 92nd ed., Internet Version 2012, in: W.M. Haynes (Ed.), Taylor & Francis group, LLC, London, 2011.
35. Characterization of thin anodic oxides of Ti–Nb alloys by electrochemical impedance spectroscopy10.1016/j.electacta.2012.06.029 ↗
36. Electrochemical stability and corrosion resistance of Ti–Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
37. Electrochemical impedance spectroscopic characterization of passive film formed over beta Ti–29Nb–13Ta–4.6Zr alloy10.1016/j.elecom.2006.06.004 ↗
38. Application of EIS to the study of corrosion behaviour of sintered ferritic stainless steels before and after high-temperature exposure10.1016/j.matchar.2006.10.008 ↗
39. XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank’s physiological solution10.1016/j.electacta.2007.12.041 ↗
40. EIS study of Ti–23Ta alloy in artificial saliva10.1179/147842208X338992 ↗
41. A. Lasia, Modern aspects of electrochemistry, in: M. Schlesinger (Ed.), Modeling of Impedance of Porous Electrodes, 2009.10.1007/978-0-387-49582-8_3 ↗
42. Electrochemical corrosion behavior of a Ti–35Nb alloy for medical prostheses10.1016/j.electacta.2008.02.011 ↗
43. Electrochemical and XPS studies of corrosion behavior of Ti–23Nb–0.7Ta–2Zr–O alloy in Ringer’s solution10.1016/j.matchemphys.2008.08.043 ↗
44. EIS study of Ti and its alloys in biological media10.1016/S0022-0728(02)00814-8 ↗
45. Electrochemical characterization of [beta]-Ti alloy in Ringer’s solution for implant application10.1016/j.jallcom.2009.01.036 ↗
46. M. Pourbaix, Atlas of electrochemical equilibria in aqueous solutions, second ed., NACE, 1974.
47. Influence of pH and fluoride concentration on titanium passivating layer: stability of titanium dioxide10.1016/S0039-9140(00)00592-0 ↗
48. The effect of fluoride on the electrochemical behavior of Ti and some of its alloys for dental applications10.1002/maco.200303770 ↗
49. Biocompatibility of beta -stabilizing elements of titanium alloys10.1016/j.biomaterials.2004.01.021 ↗
50. Influence of fluoride concentration and pH on corrosion behavior of Ti–6Al–4V and Ti–23Ta alloys in artificial saliva10.1002/maco.200604004 ↗
51. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys10.1016/S0142-9612(01)00328-3 ↗
52. Corrosive properties of fluoride-containing odontologic gels against titanium10.1016/0300-5712(95)00033-X ↗
53. Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use10.1177/00220345990780091201 ↗
54. Effects of pH and fluoride concentration on the corrosion of titanium10.1002/jbm.a.31415 ↗