Abstract The use of metallic materials for implantable medical devices has prompted numerous studies aimed at characterizing the corrosion susceptibility of these materials and understanding their electrochemical behavior in simulated and actual physiological liquids. This review focuses on the forms of corrosion that are of principal interest for Ti and its alloysin vivo: general corrosion, pitting corrosion, crevice corrosion, galvanic corrosion, and fretting corrosion. It also addresses environmentally assisted cracking in the form of hydrogen embrittlement. Of particular interest is the susceptibility of Ti and its alloys to the different forms of corrosion with regard to both solution chemistry, especially the effect of organic species, and surface characteristics such as oxide composition, surface inclusions, and wear/fretting.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

1Exponent, 149 Commonwealth Drive, Menlo Park, CA 94025, USA

References (100+)

Show source-provided references
1. urethral stents long - term results in dogs10.1007/BF00297198 ↗
2. of stainless steels New York
3. The mechanical and electrochemical processes associated with taper fretting crevice corrosion a In DE MB editors of orthopedic implants Conshohocken PA International
4. The influence of complexing agent and proteins on the corrosion of stainless steels and their metal components10.1023/A:1021505621388 ↗
5. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
6. Analysis of the effects of surface treatments on nickel release from nitinol wires and their impact on candidate gene expression in endothelial cells10.1007/s10856-006-0087-9 ↗
7. Biocompatibility of Ti shape memory alloy
8. Evaluation of couple / crevice corrosion by prosthetic alloys under in vivo conditions10.1002/jbm.820120605 ↗
9. Surface and corrosion aspects of NiTi alloys In editors Proceedings of the International Conference on Shape Memory and Superelastic Technologies CA
10. of metallic implants and prosthetic devices In editor handbook Materials OH International
11. Characterization of surface oxidation of nickel - titanium alloy by ion - beam and electrochemical techniques10.1016/j.electacta.2004.07.007 ↗
12. First - generation aortic endografts : analysis of explanted stentor devices from the EUROSTAR Registry10.1177/152660280000700205 ↗
13. Changes in nonosseous tissue adjacent to titanium implants10.1002/jbm.820070607 ↗
14. The effects of heat treatment surface condition and strain on nickel - leaching rates and corrosion performance in nitinol wires In editor Medical device materials Proceedings of the Materials and Processes for Medical Devices Materials OH
15. Fretting corrosion in saline and serum10.1002/jbm.820150404 ↗
16. Tutorial on cyclic potentiodynamic polarization technique In Paper
18. Corrosion behavior of surgical implant materials Effects of sterilization10.1016/S0010-938X(69)80081-8 ↗
19. GT editors rd ed New York
20. The effect of proteins on metallic corrosion10.1002/jbm.820160205 ↗
21. Recent observations of particulates in nitinol
22. The effect of exposure to simulated body fluids on breakdown potentials10.1007/s11665-009-9404-z ↗
23. Effect of hydrogen on the shape memory properties of Ni - Ti - Cu In AR editors Proceedings of the First International Conference on Shape Memory and Superelastic Technologies Materials OH
24. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
25. Metallic wear in failed titanium - alloy total hip replacements10.2106/00004623-198870030-00005 ↗
26. Fretting corrosion in saline and serum10.1002/jbm.820150404 ↗
27. Acceptance criteria for corrosion resistance of medical devices : statistical analysis of nitinol pitting in in vivo environments10.1007/s11665-009-9420-z ↗
28. AR Effects of hydrogen in TiNi In editors Proceedings of the Second International Conference on Shape Memory and Superelastic Technologies Materials OH
29. Electrochemical studies on the influence of proteins on the corrosion of implant alloys10.1016/0142-9612(88)90119-6 ↗
30. The composition of the surface passive film formed on CoCrMo alloys in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
31. of metal orthopaedic implants a10.2106/00004623-199802000-00015 ↗
32. The influence of complexing agent and proteins on the corrosion of stainless steels and their metal components10.1023/A:1021505621388 ↗
33. behavior of Ni - Ti shape memory alloy in a cell culture medium In editors Proceedings of the First International Conference on Shape Memory and Superelastic Technologies CA
34. GT preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro10.1007/BF00154545 ↗
35. Effect of hydrogen on the shape memory properties of Ni - Ti - Cu In AR editors Proceedings of the First International Conference on Shape Memory and Superelastic Technologies Materials OH
36. Evaluation of couple / crevice corrosion by prosthetic alloys under in vivo conditions10.1002/jbm.820120605 ↗
37. Systemic metal - protein binding associated with total joint replacement arthroplasty
38. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni - Ti alloy also in presence of stress - induced martensite10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P ↗
39. Pitting of Metals
40. urethral stents long - term results in dogs10.1007/BF00297198 ↗
41. Fretting corrosion accelerates crevice corrosion of modular hip tapers10.1002/jab.770060104 ↗
42. GI WE Polarization studies on surgical grade stainless steels in Hanks physiological solution In AC CD editors Corrosion and degradation of implant materials : second symposium Philadelphia PA International
43. Pitting corrosion In editors handbook Materials OH International
44. Pitting of stainless steel in bicarbonate and chloride solutions10.1023/A:1018499823288 ↗
45. Characterization of surface oxidation of nickel - titanium alloy by ion - beam and electrochemical techniques10.1016/j.electacta.2004.07.007 ↗
46. Orden KM Surface preparation and corrosion behavior of titanium alloys for surgical implants In editors Titanium alloys in surgical implants PA International
47. Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy Mechanically polished samples10.1002/jbm.10329 ↗
48. AB ES The ionization of metal implants in living tissues10.2106/00004623-196042010-00007 ↗
49. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide10.1002/1097-4636(200011)52:2<323::AID-JBM11>3.0.CO;2-Z ↗
50. Metallic wear in failed titanium - alloy total hip replacements10.2106/00004623-198870030-00005 ↗
51. The effects of heat treatment surface condition and strain on nickel - leaching rates and corrosion performance in nitinol wires In editor Medical device materials Proceedings of the Materials and Processes for Medical Devices Materials OH
52. Differential lymphocyte reactivity to serum - derived metal - protein complexes produced from cobalt - based and titanium - based implant alloy degradation10.1002/1097-4636(20010905)56:3<427::AID-JBM1112>3.0.CO;2-E ↗
53. In vitroandin vivocharacterization of novel plasma treated nickel titanium shape memory alloy for orthopedic implantation
54. RE - enhanced ion release the effect of static loading10.1016/0142-9612(91)90108-M ↗
55. Assessing the corrosion behavior of nitinol for minimally - invasive device design Minim Invasive Ther Allied
56. Fukushima resistance and surface characterization of electrolyzed Ti alloy10.4012/dmj.25.151 ↗
57. The electrochemical behavior of nitinol in simulated physiological solutions10.1002/jbm.a.31616 ↗
58. XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide10.1002/jbm.820280115 ↗
59. Galvanic corrosion between orthodontic wires and brackets in fluoride mouthwashes
60. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
61. Effect of chemical etching and aging in boiling water on the corrosion resistance of nitinol wires with black oxide resulting from manufacturing process10.1002/jbm.b.10017 ↗
62. Practical corrosion prediction using electrochemical techniques In editor Handbook nd ed New York
63. of the passive film on mechanically damaged nitinol
64. content of blood and estimation of dietary intake Unters Forsch
65. corrosion in saline serum10.1002/jbm.820140208 ↗
66. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
67. Comparative corrosion performance of black oxide sandblasted and fine - drawn nitinol wires in potentiodynamic and potentiostatic tests : effects of chemical etching and electropolishing
68. The effect of exposure to simulated body fluids on breakdown potentials10.1007/s11665-009-9404-z ↗
69. Interpretation of corrosion test results and prediction of clinical performance of medical devices In editors Medical device materials II Proceedings of the Materials and Processes for Medical Devices Conference Materials OH
70. of stainless steels New York
71. Microstructure nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy10.1016/j.actbio.2009.01.046 ↗
72. for determining aqueous corrosion reaction rates In editors handbook Materials OH International
73. Electrochemical behavior of Ti - based alloys in simulated human body fluid environment Trends
74. Comparative electrochemical behavior of stainless steel th Meeting XXII
75. The mechanical and electrochemical processes associated with taper fretting crevice corrosion a In DE MB editors of orthopedic implants Conshohocken PA International
76. Distribution of cobalt chromium wear and corrosion products and biologic reactions
77. MS Evaluating protein attraction and adhesion to biomaterials with the atomic force microscope10.1021/la049849+ ↗
78. of the nitinol wire of endovascular prostheses : does nickel ion release impair the devices performance ? In editors Proceedings of the Materials and Processes for Medical Devices Materials OH
79. Surface corrosion of nitinol and stainless steel under clinical conditions
80. of metallic implants and prosthetic devices In editor handbook Materials OH International
81. AR Effect of strain on the corrosion resistance of nitinol and stainless steel in simulated physiological environment In AR editors Proceedings of the International Conference Shape Memory and Superelastic Technologies CA
82. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations The effect of crevice stress motion and alloy coupling10.1002/jbm.820271210 ↗
83. Solar resistance of titanium surgical implant alloys a In editors and degradation of implant materials PA
84. resistance tests on NiTi shape memory alloy10.1016/0142-9612(95)00352-5 ↗
85. resistant alloys in chloride solutions
86. Assessing the corrosion behavior of nitinol for minimally - invasive device design Minim Invasive Ther Allied
87. Surface corrosion and biocompatibility aspects of nitinol as an implant material
88. The corrosion behavior of Ti Ti and Ti in protein solutions10.1016/S0142-9612(98)00217-8 ↗
89. Surface corrosion of nitinol and stainless steel under clinical conditions
90. AR Effect of passivation treatments on nickel release from nitinol In th World Congress for
91. The effect of surface particulates on the corrosion resistance of nitinol wire In editors Proceedings of the International Conference on Shape Memory and Superelastic Technologies CA a
92. of modular hip prostheses
93. Influence of test solutions on in vitro studies of biomedical magnesium alloys
94. The corrosion behavior of Ti Ti and Ti in protein solutions10.1016/S0142-9612(98)00217-8 ↗
95. Delayed fracture of Ni - Ti superelastic alloys in acidic and neutral fluoride solutions10.1002/jbm.a.20122 ↗
96. Corrosion behavior of surgical implant materials Effects of sterilization10.1016/S0010-938X(69)80081-8 ↗
97. Metal release in patients who have had a primary total hip arthroplasty10.2106/00004623-199810000-00006 ↗
98. Surface corrosion and biocompatibility aspects of nitinol as an implant material
99. Degradation and fracture of NiTi superelastic wire in an oral cavity10.1016/S0142-9612(00)00414-2 ↗
100. Standard Standard specification for wrought nickel - titanium shape memory alloys for medical devices and surgical implants West PA