journal article·2015-11

Increased Shape Stability and Porosity of Highly Porous Injection‐Molded Titanium Parts

Alexander M. Laptev, Natália F. Daudt, Olivier Guillon, Martin Bram

Advanced Engineering Materials· Volume 17· Issue 11
Publisher page

Abstract

Highly porous titanium parts in three different shapes (conical, cylindrical, and semi‐cylindrical) were produced using metal injection molding (MIM) and the space holder technique. Potassium chloride (KCl) powder was used as a temporary space holder material. The frequently used extraction of the KCl space holder by dissolution in warm water was replaced with sublimation from the solid state during vacuum sintering. This improvement enabled highly porous titanium parts to be manufactured by MIM without the frequently observed sample collapse or extensive shape distortion. Final porosities of 55–60% were achieved, which is close to the recommended value for porous spinal titanium implants, making improved method attractive for implant manufacturing applications. An additional advantage of removing the space holder by sublimation is that the time‐consuming salt leaching step can be omitted. A systematic study of sample configuration, porosity change, microstructure, and impurity uptake was conducted and the sintering cycle was optimized.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Forschungszentrum Jülich GmbH Institute of Energy and Climate Research Materials Synthesis and Processing (IEK‐1) 52425 Jülich Germany

Department of Mechanical Engineering Donbass State Engineering Academy Shkadinova 72 84313 Kramatorsk Ukraine

Department of Materials Engineering Universidade Federal do Rio Grande do Norte Natal 59078‐970 Brazil

References (30)

Show source-provided references
1. 10.1002/adem.20040557610.1002/adem.200405576 ↗
2. 10.1016/S0079-6425(00)00002-510.1016/S0079-6425(00)00002-5 ↗
3. Ashby M. F. · 2000 · 3
4. 10.1016/j.ijhydene.2012.01.09510.1016/j.ijhydene.2012.01.095 ↗
5. 10.1016/j.ijhydene.2008.11.05610.1016/j.ijhydene.2008.11.056 ↗
6. 10.1016/j.jpowsour.2009.06.03010.1016/j.jpowsour.2009.06.030 ↗
7. 10.1016/j.ijhydene.2013.01.15110.1016/j.ijhydene.2013.01.151 ↗
8. 10.1016/j.electacta.2014.06.17510.1016/j.electacta.2014.06.175 ↗
9. 10.1016/S0921-5093(97)00806-X10.1016/S0921-5093(97)00806-X ↗
10. 10.1016/j.pmatsci.2008.06.00410.1016/j.pmatsci.2008.06.004 ↗
11. 10.1016/S0883-5403(99)90063-310.1016/S0883-5403(99)90063-3 ↗
12. 10.1097/00003086-198007000-0004510.1097/00003086-198007000-00045 ↗
13. Wintermantel E. · 2002 · 300
14. 10.1002/jbm.a.3111810.1002/jbm.a.31118 ↗
15. 10.3390/ma705358810.3390/ma7053588 ↗
16. 10.1016/j.jmatprotec.2014.02.01610.1016/j.jmatprotec.2014.02.016 ↗
17. 10.1002/adem.20030035610.1002/adem.200300356 ↗
18. 10.1179/00325890422501553610.1179/003258904225015536 ↗
19. ASTM F67‐06 Standard Specification for Unalloyed Titanium for Surgical Implant Applications (UNS R50250 UNS R50400 UNS R50550 UNS R50700) ASTM International West Conshohocken PA USA2006.
20. 10.1179/1743290114Y.000000010810.1179/1743290114Y.0000000108 ↗
21. German R. M. · 1990 · 5
22. Nishiyabu K. · High Temp. Mater. Processes (Berlin, Ger.) · 2007 · 26 · 257
23. 10.1007/s12598-011-0430-210.1007/s12598-011-0430-2 ↗
24. 10.1016/S1003-6326(08)60424-010.1016/S1003-6326(08)60424-0 ↗
25. 10.1002/adem.20120028910.1002/adem.201200289 ↗
26. 10.1007/s11661-014-2196-210.1007/s11661-014-2196-2 ↗
27. 10.1557/jmr.2009.025610.1557/jmr.2009.0256 ↗
28. 10.1021/j100613a00510.1021/j100613a005 ↗
29. 10.1016/j.matlet.2014.11.08310.1016/j.matlet.2014.11.083 ↗
30. 10.1007/s11661-012-1485-x10.1007/s11661-012-1485-x ↗