Characterization of Biocompatible Materials Using Stereo Microscope 3D Digital Image Correlation

Tomasz Rusin, Magdalena Kopernik

Advanced Engineering Materials· Volume 18· Issue 9
Publisher page

Abstract

This paper presents the measurement of the sub‐micrometer deformation of biocompatible materials induced by mechanical and thermal loading with a newly developed stereoscopic microscope 3D digital image correlation (DIC) system. This technique combines a 3D DIC system based on two cameras in a stereoscopic setup with a stereoscopic microscope. This paper describes measurements of displacements in the range of 100 microns with an error of 0.1%, which is several times better than the accuracy provided by other comparable systems. The examined micro‐sized specimens are cut out of biocompatible material used for the construction of a pneumatic ventricular assist device. The results include a 3D surface profile, analysis of the sample surface deformations, and distribution of surface strains.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Tribology and Lubrication Engineering · Adhesion, Friction, and Surface Interactions · Optical measurement and interference techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dantec Dynamics GmbH Kaessbohrer Str. 18 D 89077 Ulm Germany

AGH University of Science and Technology al. Mickiewicza 30 30‐059 Kraków Poland

References (31)

Show source-provided references
1. Peters W. H. · Opt. Eng · 1982 · 21 · 213
2. 10.1007/BF0232509210.1007/BF02325092 ↗
3. 10.1117/1.175327010.1117/1.1753270 ↗
4. 10.1364/OL.34.00195510.1364/OL.34.001955 ↗
5. 10.1364/AO.53.00096010.1364/AO.53.000960 ↗
6. 10.1007/3-540-48800-6_1010.1007/3-540-48800-6_10 ↗
7. 10.1007/BF0242789410.1007/BF02427894 ↗
8. Burguete R. · 2010
9. 10.1051/epjconf/2010064600110.1051/epjconf/20100646001 ↗
10. 10.1364/OE.21.02505610.1364/OE.21.025056 ↗
11. 10.1002/jbm.a.3126810.1002/jbm.a.31268 ↗
12. 10.1016/j.optlaseng.2015.07.01310.1016/j.optlaseng.2015.07.013 ↗
13. 10.1364/OE.21.01180810.1364/OE.21.011808 ↗
14. 10.1016/j.optlaseng.2013.03.00110.1016/j.optlaseng.2013.03.001 ↗
15. 10.1364/AO.55.00069610.1364/AO.55.000696 ↗
16. 10.1038/nprot.2012.09610.1038/nprot.2012.096 ↗
17. Kopernik M. · Acta Bioeng. Biomech · 2015 · 17 · 49
18. 10.1002/adem.20140015710.1002/adem.201400157 ↗
19. 10.1002/adem.20150049210.1002/adem.201500492 ↗
20. 10.1007/978-0-387-78747-310.1007/978-0-387-78747-3 ↗
21. 10.4028/www.scientific.net/AMM.7-8.26510.4028/www.scientific.net/AMM.7-8.265 ↗
22. 10.1364/OE.21.01573410.1364/OE.21.015734 ↗
23. 10.1016/j.optlaseng.2012.08.00910.1016/j.optlaseng.2012.08.009 ↗
24. 10.1016/j.jmatprotec.2006.11.15410.1016/j.jmatprotec.2006.11.154 ↗
25. 10.1016/S0894-9166(14)60002-110.1016/S0894-9166(14)60002-1 ↗
26. Gonsior M. · 2013 · 582
27. Kusiński J. · 2012 · 120
28. 10.1364/JOSA.11.00023310.1364/JOSA.11.000233 ↗
29. Timoshenko S. · 1940 · 360
30. 10.1111/jmi.1243110.1111/jmi.12431 ↗
31. 10.1515/amm-2015-020910.1515/amm-2015-0209 ↗