Hydrogen Diffusion Corrosion Problems In a Fluid Catalytic Cracker And Gas Plant
Source abstract
Abstract
An account is given of corrosion problems in a fluid catalytic cracker and gas plant following a 19,000 hour run. Specific places where corrosion damage occurred and was examined include: (1) the carbon-moly steel reactor, (2) the regenerator, (3) catalyst lines, (4) the gas plant. It was found that corrosion became a problem when coupled with erosion in cyclones or diffuser grids. Alloying could not be justified except on stressed parts. Hydrogen blistering was discussed in detail. It was found that its occurrence in the gas plant was a function of pH downstream of the water wash tower. As the pH increased in the absorber deethanizer, so did the hydrogen penetration rate. Control measure finally adopted to mitigate hydrogen blistering included recording of hydrogen probe pressures, pH of draw waters, analysis of wash water, and iron content of draw waters. Ferrocyanide spot tests were also made and inhibitors were tried. 8.4.2
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Non-Destructive Testing Techniques · Material Properties and Failure Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
*Tidewater Oil Company, Avon Refinery, Associated, California.
References (6)
Show source-provided references
1. Stability of Steels at Elevated Temperatures
2. The Structure and Properties of Stainless Steels After Exposure at Elevated Temperatures
3. Effect of Sulfide Scales on Catalytic Reforming and Cracking Units, Part 2
4. Prevention of Localized Corrosion in Sulfuric Acid Handling Equipment10.5006/0010-9312-14.3.45 ↗
5. Hydrogen Blistering of Steel in Hydrogen Sulfide Solutions10.5006/0010-9312-9.5.163 ↗
6. Air Injection for Prevention of Hydrogen Penetration of Steel10.5006/0010-9312-11.10.49 ↗