journal article·2016-06-01

Reinforced Concrete Durability in Marine Environments DURACON Project: Long-Term Exposure

O. Troconis de Rincón, J.C. Montenegro, R. Vera, A.M. Carvajal, R.M. de Gutiérrez, S. Del Vasto, E. Saborio, A. Torres-Acosta, J. Pérez-Quiroz, M. Martínez-Madrid, M.G. Lomeli-González, N. Araujo-Arreola, W. Martinez-Molina, E. Alonso-Guzmán, P. Castro-Borges, M. Balancan-Zapata, T. Pérez-López, M. Sosa-Baz, M. Baltazar-Zamora, J. Genescá-Llongueras, M. Salta, A.P. de Melo, I. Martínez, N. Rebolledo, G. Rodríguez, M. Pedrón, V. Millano, M. Sánchez, E. de Partidas, K. Mendoza

Corrosion· Volume 72· Issue 6
Publisher page

Abstract

This paper presents the results, after a long-term evaluation in marine environments, from an Ibero-American project called “Effect of the environment on reinforcement durability” (DURACON). This project correlates the influence of urban and marine meteorochemical parameters on the performance of reinforced concrete structures in nine countries (Bolivia, Chile, Colombia, Costa Rica, Mexico, Spain, Uruguay, Portugal, and Venezuela). The environment was evaluated using ISO Standard 9223 and the concrete was characterized physically by measuring compressive strength, elastic modulus, total and effective porosity, as well as the effective porosity and resistance to water absorption using the Fagerlund method. To that effect, concrete specimens (with and without reinforcement) were prepared for electrochemical and physical/mechanical/chemical tests using the existing materials in each participating country, following strict procedures that enabled the preparation of similar concrete specimens. Two water/cement (w/c) ratios (0.45 and 0.65) were selected, where 0.45 w/c ratio concrete had a minimum cement content of 400 kg/m3 and the one with 0.65 w/c ratio had a minimum 28-d compressive strength of 210 kg/cm2. Type I Portland cement, siliceous sand, and crushed rock as coarse aggregates (13-mm maximum nominal size) were used. The results showed that the atmospheric aggressiveness was higher in tropical countries, especially when temperature rises above 25°C, with La Voz station (marine) in Venezuela being the most aggressive. Also, the chloride concentration threshold for rebar depassivation onset was much lower (≈0.42%) in a marine tropical environment, such as La Voz in Venezuela, compared to a nontropical one, such as Cabo Raso in Portugal (≈0.89%), with this concentration dependent on rebar depth and influenced by environmental factors such as time of wetness and ambient temperature, and not only from physical concrete properties.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

*Centro de Estudios de Corrosión, Universidad del Zulia, Maracaibo, Zulia, 4007, Venezuela.

B Bolivia;

CH Chile;

CO Colombia;

CR Costa Rica;

M Mexico;

P Portugal;

S Spain;

U Uruguay;

V Venezuela.

References (33)

Show source-provided references
1. Wallbank · 1989
2. “Retrospectiva da Patología no Brasil; Estudo Estatístico,”
3. Troconis de Rincón · Construcción y Obras Públicas Latinoamérica · 1997 · 4 · 20
4. “La Carbonatación en el Trópico Caso Típico: Estadio Pachencho Romero,”
5. Mangat · Mater. Structures · 1994 · 27 · 33810.1007/BF02473426 ↗
6. “Modelling of Chloride Ingress in the Lake Maracaibo Bridge,”
7. Trocónis de Rincón · Building and Environment · 2004 · 39 · 106510.1016/j.buildenv.2004.01.036 ↗
8. Trocónis de Rincón · 2001
9. “Chloride Critical Concentrations for the Onset of Active Reinforcement Corrosion,”
10. “Chloride Threshold Levels for Corrosion Induced Deterioration of Steel in Concrete,”
11. Alonso · Cement Concrete Research · 2000 · 30 · 104710.1016/S0008-8846(00)00265-9 ↗
12. “The Chloride Threshold for Corrosion Onset of Reinforced Concrete in Two Tropical Marine Micro-Climates of Yucatán, México,”
13. “Corrosion Forescasting for 75-Year Durability Design of Reinforced Concrete,”
14. Ann · Corros. Sci. · 2007 · 49 · 411310.1016/j.corsci.2007.05.007 ↗
15. “Atmospheric Corrosion in Ibero-America: The MICAT Project,”10.1520/STP14924S ↗
16. Troconis de Rincón · Building and Environment · 2006 · 41 · 95210.1016/j.buildenv.2005.04.005 ↗
17. “Remaining Life of Reinforced Concrete Structures After Corrosion Cracking,”
18. Torres-Acosta · Corrosion · 2013 · 69 · 112210.5006/0844 ↗
19. Cabrera-Madrid · 2014 · 8211
20. “Standard Test Method for Compressive Strength of Cylindrical Test Specimens”
21. Fagerlund · 1982 · 6
22. Trocónis de Rincón · Corros. Sci. · 2007 · 49 · 283210.1016/j.corsci.2007.02.009 ↗
23. “Corrosion of Metals and Alloys—Corrosivity of Atmospheres—Classification, Determination and Estimation”
24. “Corrosion Detecting Probes for Use with a Corrosion-Rate Meter for Electrochemically Determining the Corrosion Rate of Reinforced Structures,”
25. Feliu · ACI Mater. J. · 1990 · 87 · 457
26. “Proyecto DURACON: Maquina para Obtener Secciones Rectas de Prismas de Hormigón de Sección Cuadrada,”
27. “Rediseño y Construcción de una Máquina Cortadora de Probetas de Hormigón de Sección Cuadrada”
28. RILEM Technical Committees TC 178-TMC · Mater. Structures · 2002 · 35 · 586
29. Araujo · Revista Técnica de la Facultad de Ingeniería · 2011 · 34 · 14
30. “Methodology Based on the Electrical Resistivity for the Calculation of Reinforcement Service Life,”
31. Morón · Revista Técnica de la Facultad de Ingeniería · 2003 · 26 · 65
32. “Main Complications for Modeling and Predicting Service Life of Reinforced Concrete Structures,”
33. “Impacto del Medio Ambiente y de los Materiales en la Durabilidad de las Estructuras de Concreto Armado Expuestas a Medios Marinos y Urbanos”