journal article·2007-10-01

A Galvanic Sensor for Monitoring the Corrosion Damage of Buried Pipelines: Part 3—Correlation of Probe Current to Cathodic Protection and Stray Current

Y.-S. Choi, J.-G. Kim, J.-Y. Koo

Corrosion· Volume 63· Issue 10
Publisher page

Abstract

In order to develop a new corrosion sensor for monitoring the status of cathodic protection of buried pipelines, the correlation of sensor output to protection abilities (protection potential and current) was evaluated using two types of laboratory tests. The galvanic sensor uses the well-known principle of galvanic corrosion and consists of two dissimilar metals (acting as the anode and cathode) installed in the soil near the pipeline. In this paper, a copper-pipeline steel (Cu-CS) probe was used. The cathodic protection status of the pipeline was simulated by a galvanostatic test. The galvanic current density was measured using a zero-resistance ammeter for the Cu-CS probe with the anode (CS) either connected or disconnected to the pipeline. The results showed a good correlation between the protection potential/current of the pipeline and the sensor output. Especially when the protection current was induced to the pipeline, the measured sensor current was negative (–), whereas when the stray current was removed from the pipeline, the measured sensor current was positive (+). This indicates that the direction of sensor current reflects the status of the pipeline with cathodic protection or stray current corrosion, confirming that the Cu-CS galvanic probe is an effective tool for monitoring the effectiveness of cathodic protection.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Concrete Corrosion and Durability · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

*Department of Advanced Materials Engineering, Sungkyunkwan University, 300 Chunchun-Dong, Jangan-Gu, Suwon, 440-746, Korea.

**Department of Environmental Engineering, The University of Seoul, 90 Jeonnogn-Dong, Tongdaemun-Gu, Seoul, 130-743 Korea.

References (19)

Show source-provided references
1. Klechka · Mater. Perform. · 2002 · 41 · 24
2. Peabody · 1967 · 5
3. Fontana · 1986 · 383
4. Li · Corros. Sci. · 2002 · 44 · 68910.1016/S0010-938X(01)00042-7 ↗
5. Control of External Corrosion on Underground or Submerged Metallic Piping Systems
6. Heidersbach · 1987 · 466
7. Parker · 1984 · 27
8. Cathodic Protection Parameters Measured on Corrosion Coupons and Pipes Buried in the Field
9. Online Monitoring of Corrosion Under Cathodic Protection Conditions Utilizing Coupled Multielectrode Sensors
10. Field Tests on an Advanced Cathodic Protection Coupon
11. In-Situ Corrosivity Monitoring of Military Hardware Environments
12. On the Correlation of Bimetallic Corrosion Sensor Output to Actual Corrosion Damage
13. A Galvanic Sensor for Monitoring the Corrosion Damage of Buried Pipelines: Part 1. Laboratory Tests to Determine the Correlation of Probe Current to Actual Corrosion Damage
14. A Galvanic Sensor for Monitoring the Corrosion Damage of Buried Pipelines: Part 2. Laboratory Electrochemical Testing of Sensors in Soil
15. A Galvanic Sensor for Monitoring the Corrosion Damage of Buried Pipelines: Part 3. Electrochemical Tests to Determine the Correlation of Probe Current to Internal Corrosion Damage in Synthetic Tap Water
16. Choi · Corrosion · 2005 · 61 · 29310.5006/1.3280638 ↗
17. Choi · Corrosion · 2006 · 62 · 52210.5006/1.3279911 ↗
18. Kim · Corrosion · 2002 · 58 · 17510.5006/1.3277318 ↗
19. Kim · Corros. Sci. · 2001 · 43 · 2,01110.1016/S0010-938X(01)00015-4 ↗