journal article·2020-05Open access

Tomographic Reconstruction and Analysis of a Silver CO2 Reduction Cathode

David McLaughlin, Markus Bierling, Riko Moroni, Christoph Vogl, Günter Schmid, Simon Thiele

Advanced Energy Materials· Volume 10· Issue 19

Abstract

Abstract Tomographic reconstruction has been well established as a valuable tool in the analysis of polymer electrolyte fuel cell (PEMFC) electrodes. While forays have been made into applying it to polymer electrolyte water electrolyzer (PEMWE) electrodes, CO2 electrolyzer electrodes are still new ground. Here a tomographic analysis of an electrochemical CO2 reduction gas diffusion electrode by means of focused ion beam scanning electron microscope tomography is presented. The reconstruction shows a porosity of 68%. While most of the porosity is on the nanoscale, a broad tail of micropores is observed in the distribution. The spatial distribution of the pores is nonuniform. The large pores are concentrated in the center of the layer in the through‐plane direction. From the reconstruction, an effective diffusivity factor of 0.5 for the catalyst layer is calculated. The Knudsen number of 0.19 obtained from the later shows that the diffusion is mostly in the bulk regime. Flooding of the catalyst layer is likely to decrease the effective diffusivity factor substantially.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: CO2 Reduction Techniques and Catalysts · Electrocatalysts for Energy Conversion · Fuel Cells and Related Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Forschungszentrum Jülich GmbH Helmholtz‐Institute Erlangen‐Nürnberg for Renewable Energy (IEK‐11) Egerlandstr. 3 Erlangen 91058 Germany

Department of Chemical and Biological Engineering Friedrich‐Alexander‐University Erlangen‐Nürnberg Egerlandstr. 3 Erlangen 91058 Germany

IMTEK Department of Microsystems Engineering Laboratory for MEMS Applications University of Freiburg Georges‐Koehler‐Allee 103 Freiburg 79110 Germany

Siemens AG Erlangen Gas and Power Günther‐Scharowsky‐Str. 1 Erlangen 91058 Germany

Funding

Bundesministerium für Bildung und Forschung

References (35)

Show source-provided references
1. 10.1002/adma.20180716610.1002/adma.201807166 ↗
2. 10.1039/C5GC01893E10.1039/C5GC01893E ↗
3. 10.1039/C8EE00097B10.1039/C8EE00097B ↗
4. 10.1002/cssc.20160039410.1002/cssc.201600394 ↗
5. 10.1021/jz101262710.1021/jz1012627 ↗
6. 10.1016/j.pecs.2017.05.00510.1016/j.pecs.2017.05.005 ↗
7. 10.1021/acs.accounts.8b0001010.1021/acs.accounts.8b00010 ↗
8. 10.1021/acsenergylett.8b0173410.1021/acsenergylett.8b01734 ↗
9. 10.1126/science.aas910010.1126/science.aas9100 ↗
10. 10.1038/s41929-017-0005-110.1038/s41929-017-0005-1 ↗
11. 10.1039/C5TA01341K10.1039/C5TA01341K ↗
12. 10.1016/j.jpowsour.2016.06.13210.1016/j.jpowsour.2016.06.132 ↗
13. 10.1149/2.0581914jes10.1149/2.0581914jes ↗
14. Bühler M. · J. Mater. Chem. A · 2019 · 165 · F305
15. 10.1149/1.208651510.1149/1.2086515 ↗
16. Burdyny T. · Energy Environ. Sci. · 2019 · 57 · 2165
17. 10.1039/C8CP01319E10.1039/C8CP01319E ↗
18. 10.2533/chimia.2019.92210.2533/chimia.2019.922 ↗
19. 10.1016/j.jpowsour.2016.02.04310.1016/j.jpowsour.2016.02.043 ↗
20. 10.1002/aenm.20120075910.1002/aenm.201200759 ↗
21. 10.1038/nmat166810.1038/nmat1668 ↗
22. 10.1016/j.jpowsour.2010.09.04410.1016/j.jpowsour.2010.09.044 ↗
23. 10.1016/j.jpowsour.2018.04.08910.1016/j.jpowsour.2018.04.089 ↗
24. 10.1002/aenm.20140161210.1002/aenm.201401612 ↗
25. 10.1149/2.0111611jes10.1149/2.0111611jes ↗
26. 10.1039/C6RA16560E10.1039/C6RA16560E ↗
27. 10.1016/j.jpowsour.2015.03.11010.1016/j.jpowsour.2015.03.110 ↗
28. 10.1016/j.commatsci.2018.09.03310.1016/j.commatsci.2018.09.033 ↗
29. 10.3390/ma1217268610.3390/ma12172686 ↗
30. 10.1016/j.jpowsour.2016.05.10810.1016/j.jpowsour.2016.05.108 ↗
31. 10.1115/1.403724410.1115/1.4037244 ↗
32. 10.1002/ente.20160063610.1002/ente.201600636 ↗
33. 10.1149/2.0501815jes10.1149/2.0501815jes ↗
34. 10.1016/j.jcou.2019.03.02210.1016/j.jcou.2019.03.022 ↗
35. 10.1007/s12274-011-0141-x10.1007/s12274-011-0141-x ↗