journal article·2018-09

Effects of combined environmental exposures and axial load on CFFT

Song Wang, Mohamed A. ElGawady

Publisher page

Abstract

Abstract Concrete-filled fiber-reinforced polymer tube (CFFT) columns have demonstrated superior advantages on mechanical behavior and ease of construction during the past few decades. The fiber-reinforced polymer (FRP) tube not only improves the mechanical properties of the concrete core by confinement, but also provides a protection layer for the concrete against the outer corrosive environment. However, one obstacle hindering the greater acceptance of the FRP composite as a conventional construction material in civil engineering applications is the susceptibility of FRP to complex, severe environmental exposure. The purpose of this study is to investigate the durability of CFFT cylinders with glass fiber reinforced polymer (GFRP) tubes under exposure to combined freeze/thaw, heating/cooling, and wet/dry cycles. The effects of combined sustained load and environmental conditions were also investigated during this study. Compression and hoop tensile tests were carried out on both conditioned and controlled specimens. In addition, scanning electron microscopy (SEM) and differential-scanning calorimetry (DSC) tests were used to characterize the aging effect on physical and thermal properties of FRP material. Test results showed that more pronounced degradation occurred on the ultimate strain than on the ultimate strength. The sustained load had a negative effect on CFFT cylinders by creating more microcracks in the GFRP tube.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Evaluation of sandwich panels with various polyureathane foam-cores and ribs10.1016/j.compositesb.2015.04.023 ↗
2. Strain rate effect on properties of rubberized concrete confined with glass fiber-reinforced polymers10.1061/(ASCE)CC.1943-5614.0000658 ↗
3. Concrete-filled-large deformable FRP tubular columns under axial compressive loading10.3390/fib3040432 ↗
4. Displacement-based model to predict lateral drift capacities of concrete-filled FRP tube columns10.1016/j.engstruct.2017.05.045 ↗
5. Behavior of concrete-filled FRP tubes under cyclic axial compression10.1061/(ASCE)CC.1943-5614.0000523 ↗
6. Combined effects of saline solution and moist concrete on long-term durability of GFRP reinforcing bars10.1016/j.conbuildmat.2012.08.021 ↗
7. Durability gap analysis for fiber-reinforced polymer composites in civil infrastructure10.1061/(ASCE)1090-0268(2003)7:3(238) ↗
8. Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures10.1016/j.compstruct.2005.08.015 ↗
9. Accelerated test methods to determine the long-term behavior of FRP composite structures: environmental effects10.1177/073168449501400602 ↗
10. Examination of the time-water content superposition on the dynamic viscoelasticity of moistened polyamide 6 and epoxy10.1002/app.20465 ↗
11. Discussion of the molecular mechanisms of moisture transport in epoxy resins10.1002/(SICI)1099-0488(20000301)38:5<792::AID-POLB16>3.0.CO;2-H ↗
12. Sorption and diffusion of water, salt water, and concrete pore solution in composite matrices10.1002/(SICI)1097-4628(19990118)71:3<483::AID-APP15>3.0.CO;2-S ↗
13. Characterization of fatigue and combined environment on durability performance of glass/vinyl ester composite for infrastructure applications10.1016/S0142-1123(99)00100-0 ↗
14. Elastic modulus variation due to moisture absorption and permanent changes upon redrying in an epoxy based underfill10.1109/TCAPT.2005.853172 ↗
15. Structural fiber composite materials for cold regions10.1061/(ASCE)0887-381X(1988)2:3(124) ↗
16. Effect of moisture absorption on the mechanical properties of randomly oriented natural fibers/polyester hybrid composite10.1016/j.msea.2009.04.027 ↗
17. Exploring durability of interfaces in flax fibre/epoxy micro-composites10.1016/j.compositesa.2013.01.010 ↗
18. Temperature effect during humid ageing on interfaces of glass and carbon fibers reinforced epoxy composites10.1016/j.jcis.2005.12.023 ↗
19. Effects of freezing and thawing cycles and sustained loading on compressive strength of precast concrete composite piles10.15554/pcij.01012008.109.120 ↗
20. Evaluation effects of the short- and long-term freeze-thaw exposure on the axial behavior of concrete-filled glass fiber-reinforced-polymer tubes10.1155/2013/340672 ↗
21. Harsh environments effects on the axial behaviour of circular concrete-filled fibre reinforced-polymer (FRP) tubes10.1016/j.compositesb.2015.08.054 ↗
22. Self-compacting concrete10.3151/jact.1.5 ↗
23. ASTM D3039/D3039M-17 Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials, ASTM 2017 International, West Conshohocken, PA.
24. ASTM D2290–16 Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe, ASTM 2016 International, West Conshohocken, PA.
25. ASTM D2105–01(2014) Standard Test Method for Longitudinal Tensile Properties of “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Tube, ASTM 2014 International, West Conshohocken, PA.
26. ASTM D1599–14e1 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings, ASTM 2014 International, West Conshohocken, PA.
27. ASTM C39/C39M-18 Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens, ASTM 2018 International, West Conshohocken, PA.
28. ASTM –08 Standard Test Method for Assignment of the Glass Transition Temperatures by Differential Scanning Calorimetry, ASTM 2014 International, West Conshohocken, PA.
29. Behavior of hollow-core steel-concrete-steel columns subjected to torsion loading10.1061/(ASCE)BE.1943-5592.0000923 ↗
30. Durability of FRP rods for concrete structures10.1016/j.conbuildmat.2004.04.012 ↗
31. Durability of GFRP Reinforced Concrete in Field Structures
32. Effect of hygrothermal aging on the mechanical properties of fluorinated and nonfluorinated clay-epoxy nanocomposites10.1155/2014/489453 ↗
33. A.H. Siddhwartha Mandal, F. Amir, Influence of concrete strength on confinement effectiveness of fiber-reinforced polymer circular jackets, Struct. J. 102(3).
34. Experimental study of normal- and High-strength concrete confined with fiber-reinforced polymers10.1061/(ASCE)CC.1943-5614.0000116 ↗
35. L. Bisby, S. Li, B. Duerden, K. McLarty, J.F. Chen, T. Stratford, Effects of unconfined concrete strength on FRP confinement of concrete, in: Proceedings of the 6th International Conference on FRP Composites in Civil Engineering, CICE 2012, International Institute for FRP in Construction (IIFC) 2012.
36. Influence of fiber orientation and specimen end condition on axial compressive behavior of FRP-confined concrete10.1016/j.conbuildmat.2013.05.085 ↗
37. Moisture penetration into composites under external stress10.1002/pc.750020310 ↗
38. Behavior of FRP-confined normal- and high-strength concrete under cyclic axial compression10.1061/(ASCE)CC.1943-5614.0000273 ↗