Effects of bolted connections on behaviour of timber frames under combined vertical and lateral loads
Source abstract
Abstract
Abstract In this paper, a new bolted beam-column connection comprising of top-and-seat steel angles and bolts was used in timber frames and its influence on structural behaviour was determined through comparisons with connections with slotted-in steel-plates. In the experimental programme, three full-scale timber frames were tested to failure under combined vertical and lateral loads and their load capacity and lateral stiffness were obtained. Different failure modes of frames were also observed at beam-column connections and column bases. Strains at selected sections of beams and columns were measured by using strain gauges and rotations of beam-column connections and column bases were also captured by using displacement transducers. Bending moments at beam and column ends were calculated based on plane-section assumption and moment-rotation relationships of beam-column connections and column bases were established. Test results showed that timber frame with top-and-seat-steel-angle connections could develop 44% higher lateral stiffness and 20% greater load capacity than the frame with slotted-in steel-plate connections. The increases in stiffness and load capacity mainly resulted from the 3.0 times higher rotational stiffness of top-and-seat-steel-angle connections than that of slotted-in steel-plate connections. By decreasing the cross-section of beams and columns in the frame with top-and-seat-steel-angle connections, the rotational stiffness of connections was slightly reduced, but the connection could still sustain significant bending moments under lateral loads.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Wood Treatment and Properties · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Bolted glulam beam-column connections under different combinations of shear and bending10.1016/j.engstruct.2018.12.024 ↗
2. Rotational performance of glulam bolted joints: Experimental investigation and analytical approach10.1016/j.conbuildmat.2019.03.002 ↗
3. Analysis of dowelled timber to timber moment-resisting joints10.1617/s11527-006-9210-0 ↗
4. Numerical 3D finite element modelling and experimental tests for dowel-type timber joints10.1016/j.conbuildmat.2009.04.006 ↗
5. Numerical simulation of embedding strength of glued laminated timber for dowel-type fasteners10.1007/s10086-012-1296-0 ↗
6. Comparison of glulam post-to-beam connections reinforced by two different dowel-type fasteners10.1016/j.conbuildmat.2015.09.005 ↗
7. M. Gehloff, M. Closen, F. Lam, Reduced edge distance in bolted timber moment connections with perpendicular to grain reinforcements, 11th World Conference on Timber Engineering WCTE2010, New York, USA, 2010.
8. Splitting of timber beams caused by perpendicular to grain forces of multiple connections10.1016/j.engstruct.2018.05.059 ↗
9. F. Lam, M. Schulte-Wrede, C.C. Yao, J.J. Gu, Moment resistance of bolted timber connections with perpendicular to grain, 10th World Conference on Timber Engineering WCTE2008, Miyazaki, Japan, 2008.
10. Moment-resisting bolted timber connections10.1680/stbu.2010.163.4.267 ↗
11. Feasibility of improved slotted bolted connection for timber moment frames10.1007/s10086-010-1165-7 ↗
12. Advances in moment transfering dvw reinforced timber connections –analysis and experimental verification, Part 110.1016/j.conbuildmat.2013.03.020 ↗
13. Rotational behavior of bolted glulam beam-to-column connections with knee brace10.1016/j.engstruct.2020.110251 ↗
14. Experimental study of the lateral resistance of bolted glulam timber post and beam structural systems10.1061/(ASCE)ST.1943-541X.0001205 ↗
15. Experimental testing of full-scale glulam frames with buckling restrained braces10.1016/j.engstruct.2020.111081 ↗
16. Lateral loading behavior of glulam frame-midply hybrid lateral systems10.1016/j.conbuildmat.2019.05.182 ↗
17. Seismic design and performance evaluation of self-centering timber moment resisting frames10.1016/j.soildyn.2018.08.038 ↗
18. Ministry of Housing and Urban-Rural Development · 2017
19. ASTM, Standard Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings, E564-06, ASTM International, West Conshohocken, PA, 2018.
20. ISO, Timber structures-Glued laminated timber-Test methods for determination of physical and mechanical properties, ISO 8375: 2009(E), Switzerland, 2009.
21. ISO, Timber structures-Dowel-type fasteners-Part 1: Determination of yield moment, ISO 10984-1: 2009(E), Switzerland, 2009.
22. M. Yasumura, N. Kawai, Estimating seismic performance of wood-framed structures, International Wood Engineering Conference, Lausanne, Switzerland, 1998.
23. BSI, Eurocode 3: Design of steel structures—Part 1-8: Design of joints, BS EN 1993-1-8:2005, British Standards Institution, London, 2005.
24. Standards Press of China · 2009